scholarly journals Technological Reliability and Efficiency of Wastewater Treatment in Two Hybrid Constructed Wetlands in the Roztocze National Park (Poland)

Water ◽  
2020 ◽  
Vol 12 (12) ◽  
pp. 3435
Author(s):  
Agnieszka Micek ◽  
Krzysztof Jóźwiakowski ◽  
Michał Marzec ◽  
Agnieszka Listosz

The paper presents the results of a 3-year study on the technological reliability and the efficiency of typical domestic wastewater treatment in two hybrid constructed wetland systems (CWs) located in the area of the Roztocze National Park (Poland). The studied objects consist of an initial settling tank and a system of two beds of the vertical flow (VF) and horizontal flow (HF) (VF–HF) type with reed and willow. The wastewater flow rate in the constructed wetlands systems (CWs) was 0.4 and 1.0 m3/d, respectively. During the study period (2017–2019) 20 series of analyses were performed and 60 wastewater samples were collected. Based on the obtained results the effects of pollutant removal and the technological reliability were determined, which were specified with the Weibull method. The average efficiency of biochemical oxygen demand (BOD5) and chemical oxygen demand (COD) removal was 96–99%. Slightly lower effects were obtained in the case of total phosphorus (TP) removal (90–94%), as well as for total suspended solids (TSS) (80–87%) and total nitrogen (TN) (73–86%) removal. The analysed CWs were characterised by 100% technological reliability for BOD5 and COD, as well as a good reliability for TSS and TP (87–100%) but slightly lower for TN removal (35–89%). Hybrid CWs of VF–HF type should be recommended to use in protected areas for wastewater treatment and water resources quality protection.

2021 ◽  
Vol 11 (4) ◽  
pp. 1889 ◽  
Author(s):  
Agnieszka Micek ◽  
Krzysztof Jóźwiakowski ◽  
Michał Marzec ◽  
Agnieszka Listosz ◽  
Tadeusz Grabowski

The results of research on the efficiency and technological reliability of domestic wastewater purification in two household wastewater treatment plants (WWTPs) with activated sludge are presented in this paper. The studied facilities were located in the territory of the Roztocze National Park (Poland). The mean wastewater flow rate in the WWTPs was 1.0 and 1.6 m3/day. In 2017–2019, 20 series of analyses were done, and 40 wastewater samples were taken. On the basis of the received results, the efficiency of basic pollutant removal was determined. The technological reliability of the tested facilities was specified using the Weibull method. The average removal efficiencies for the biochemical oxygen demand in 5 days (BOD5) and chemical oxygen demand (COD) were 66–83% and 62–65%, respectively. Much lower effects were obtained for total suspended solids (TSS) and amounted to 17–48%, while the efficiency of total phosphorus (TP) and total nitrogen (TN) removal did not exceed 34%. The analyzed systems were characterized by the reliability of TSS, BOD5, and COD removal at the level of 76–96%. However, the reliability of TN and TP elimination was less than 5%. Thus, in the case of biogenic compounds, the analyzed systems did not guarantee that the quality of treated wastewater would meet the requirements of the Polish law during any period of operation. This disqualifies the discussed technological solution in terms of its wide application in protected areas and near lakes, where the requirements for nitrogen and phosphorus removal are high.


2020 ◽  
Vol 82 (9) ◽  
pp. 1877-1884
Author(s):  
Güler Türkoğlu Demirkol ◽  
Gökhan Balcıoğlu ◽  
Nurtaç Öz ◽  
Moiz Elnekave ◽  
Bülent Armağan ◽  
...  

Abstract Domestic wastewaters causing pollution contain inorganic and/or organic materials. When the domestic wastewater outflows to the receiving waters, it causes physical, chemical, and biological pollution in them, and deteriorates the ecological balance of those waters. In the treatment of wastewater, various treatment methods are available depending on the pollution strength of the wastewater. Besides mechanical and biological methods, wastewater treatment with physicochemical methods is still one of the most effective and economical options. Particularly in wastewater with a high concentration of suspended solids, this method is very successful, and obtaining high suspended solids removal efficiencies is very possible. In this study, the effects of the use of coagulant and coagulant aid to be used in a treatment plant where domestic wastewater treatment is carried out are determined to increase the treatment efficiency of a biological treatment that comes later in the stages of the treatment. The effluent of the pre-settling tank may contain a lot of suspended solids. This presence of excess suspended solids decreases the efficiency at other levels of treatment and causes energy loss. In the experiments, the standard jar and inhibition tests are done as a method. As a result of the conducted studies, it is determined that the FeCl3, Synthetic coagulant LP 526, FeClSO4, and the combination of anionic polyelectrolyte yield the best results in the removal of the parameters of chemical oxygen demand (COD), total suspended solids (TSS), and volatile suspended solids (VSS). While FeCl3, APE 65, APE 85, Synthetic coagulant LP 526, and FeClSO4 did not show any inhibition effect in the sludge, APE 67, CPE 84, and (Al2(SO4)3 are found to cause inhibition in the sludge.


2013 ◽  
Vol 69 (2) ◽  
pp. 350-357 ◽  
Author(s):  
Miriam Ben-shalom ◽  
Semion Shandalov ◽  
Asher Brenner ◽  
Gideon Oron

Three pilot-scale duckweed pond (DP) wastewater treatment systems were designed and operated to examine the effect of aeration and effluent recycling on treatment efficiency. Each system consisted of two DPs in series fed by pre-settled domestic sewage. The first system (duckweed+ conventional treatment) was ‘natural’ and included only duckweed plants. The second system (duckweed aeration) included aeration in the second pond. The third system (duckweed+ aeration+ circulation) included aeration in the second pond and effluent recycling from the second to the first pond. All three systems demonstrated similarly efficient removal of organic matter and nutrients. Supplemental aeration had no effect on either dissolved oxygen levels or on pollutant removal efficiencies. Although recycling had almost no influence on nutrient removal efficiencies, it had a positive impact on chemical oxygen demand and total suspended solids removals due to equalization of load and pH, which suppressed algae growth. Recycling also improved the appearance and growth rate of the duckweed plants, especially during heavy wastewater loads.


Author(s):  
Manoj Kumar ◽  
Rajesh Singh

In the present study area-based, pollutant removal kinetic analysis was considered using the Zero-order, first-order decay and efficiency loss (EL) models in the constructed wetlands (CWs) for municipal wastewater treatment....


2015 ◽  
Vol 71 (9) ◽  
pp. 1333-1339 ◽  
Author(s):  
A. Morvannou ◽  
N. Forquet ◽  
S. Michel ◽  
S. Troesch ◽  
P. Molle

Approximately 3,500 constructed wetlands (CWs) provide raw wastewater treatment in France for small communities (<5,000 people equivalent). Built during the past 30 years, most consist of two vertical flow constructed wetlands (VFCWs) in series (stages). Many configurations exist, with systems associated with horizontal flow filters or waste stabilization ponds, vertical flow with recirculation, partially saturated systems, etc. A database analyzed 10 years earlier on the classical French system summarized the global performances data. This paper provides a similar analysis of performance data from 415 full-scale two-stage VFCWs from an improved database expanded by monitoring data available from Irstea and the French technical department. Trends presented in the first study are confirmed, exhibiting high chemical oxygen demand (COD), total suspended solids (TSS) and total Kjeldahl nitrogen (TKN) removal rates (87%, 93% and 84%, respectively). Typical concentrations at the second-stage outlet are 74 mgCOD L−1, 17 mgTSS L−1 and 11 mgTKN L−1. Pollutant removal performances are summarized in relation to the loads applied at the first treatment stage. While COD and TSS removal rates remain stable over the range of applied loads, the spreading of TKN removal rates increases as applied loads increase.


Water ◽  
2016 ◽  
Vol 8 (9) ◽  
pp. 365 ◽  
Author(s):  
Eleanor Butterworth ◽  
Andrew Richards ◽  
Mark Jones ◽  
Gabriella Mansi ◽  
Ezio Ranieri ◽  
...  

2017 ◽  
Vol 76 (1) ◽  
pp. 124-133 ◽  
Author(s):  
Ania Morvannou ◽  
Stéphane Troesch ◽  
Dirk Esser ◽  
Nicolas Forquet ◽  
Alain Petitjean ◽  
...  

French vertical flow constructed wetlands (VFCW) treating raw wastewater have been developed successfully over the last 30 years. Nevertheless, the two-stage VFCWs require a total filtration area of 2–2.5 m2/P.E. Therefore, implementing a one-stage system in which treatment performances reach standard requirements is of interest. Biho-Filter® is one of the solutions developed in France by Epur Nature. Biho-Filter® is a vertical flow system with an unsaturated layer at the top and a saturated layer at the bottom. The aim of this study was to assess this new configuration and to optimize its design and operating conditions. The hydraulic functioning and pollutant removal efficiency of three different Biho-Filter® plants commissioned between 2011 and 2012 were studied. Outlet concentrations of the most efficient Biho-Filter® configuration are 70 mg/L, 15 mg/L, 15 mg/L and 25 mg/L for chemical oxygen demand (COD), 5-day biological oxygen demand (BOD5), total suspended solids (TSS) and total Kjeldahl nitrogen (TKN), respectively. Up to 60% of total nitrogen is removed. Nitrification efficiency is mainly influenced by the height of the unsaturated zone and the recirculation rate. The optimum recirculation rate was found to be 100%. Denitrification in the saturated zone works at best with an influent COD/NO3-N ratio at the inflet of this zone larger than 2 and a hydraulic retention time longer than 0.75 days.


2018 ◽  
Vol 13 (3) ◽  
pp. 457-464
Author(s):  
PRIYANAND AGALE ◽  
PARAG SADGIR

Rural wastewater treatment is mostly ignored in developing and undeveloped countries. The most important barrier for addressing to this problem is cost of treatment and simplified technology. Aerobic Brickbat Grit Sand (ABGS) purifier consists of four stages. Wastewater flows gravitationally through partition walls in zigzag pattern with brick bats filter; Pebble sand filter and charcoal and grit filter which facilitate removal of contaminants from domestic wastewater. In the present study, experimental model for domestic wastewater treatment was setup in the Environmental Engineering laboratory at Government College of Engineering Aurangabad, Maharashtra. Physiochemical analysis was done in August and September of 2016 the percentage removal of contaminants results shows Biological Oxygen Demand (BOD) 92% - 87%, Chemical Oxygen Demand (COD) 93 - 89%, Total Suspended Solids( TSS) 80 - 78% and Turbidity 95 - 85%. The process is considered eco-friendly and easy to install technology for domestic wastewater treatment with use of locally available material. ABGS purifier is decentralized approach of domestic wastewater treatment. Hence ABGS as an alternative solution to tackle over the problem of rural wastewater treatment.


2010 ◽  
Vol 62 (10) ◽  
pp. 2408-2418 ◽  
Author(s):  
C. Y. Wu ◽  
J. K. Liu ◽  
S. H. Cheng ◽  
D. E. Surampalli ◽  
C. W. Chen ◽  
...  

In Taiwan, more than 20% of the major rivers are mildly to heavily polluted by domestic, industrial, and agricultural wastewaters due to the low percentage of sewers connected to wastewater treatment plants. Thus, constructed or engineered wetlands have been adopted as the major alternatives to clean up polluted rivers. Constructed wetlands are also applied as the tertiary wastewater treatment systems for the wastewater polishment to meet water reuse standards with lower operational costs. The studied Kaoping River Rail Bridge Constructed Wetland (KRRBCW) is the largest constructed wetland in Taiwan. It is a multi-function wetland and is used for polluted creek water purification and secondary wastewater polishment before it is discharged into the Kaoping River. Although constructed wetlands are feasible for contaminated water treatment, wetland sediments are usually the sinks for organics and metals. In this study, water and sediment samples were collected from the major wetland basins in KRRBCW. The investigation results show that more than 97% of total coliforms (TC), 55% of biochemical oxygen demand (BOD), and 30% of nutrients [e.g. total nitrogen (TN), total phosphorus (TP)] were removed via the constructed wetland system. However, results from the sediment analyses show that wetland sediments contained high concentrations of metals (e.g. Cu, Fe, Zn, Cr, and Mn), organic contents (sediment oxygen demand = 1.7 to 7.6 g O2/m2 d), and nutrients (up to 18.7 g/kg of TN and 1.22 g/kg of TN). Thus, sediments should be excavated periodically to prevent the release the pollutants into the wetland system and causing the deterioration of wetland water quality. Results of polymerase chain reaction (PCR), denaturing gradient gel electrophoresis (DGGE), and nucleotide sequence analysis reveal that a variation in microbial diversity in the wetland systems was observed. Results from the DGGE analysis indicate that all sediment samples contained significant amounts of microbial ribospecies, which might contribute to the carbon degradation and nitrogen removal. Gradual disappearance of E. coli was also observed along the flow courses through natural attenuation mechanisms.


Sign in / Sign up

Export Citation Format

Share Document