scholarly journals Algae-Laden Fouling Control by Gravity-Driven Membrane Ultrafiltration with Aluminum Sulfate-Chitosan: The Property of Floc and Cake Layer

Water ◽  
2020 ◽  
Vol 12 (7) ◽  
pp. 1990 ◽  
Author(s):  
Peng Du ◽  
Xing Li ◽  
Yanling Yang ◽  
Zhiwei Zhou ◽  
Xiaoyan Fan ◽  
...  

Gravity-driven membrane (GDM) ultrafiltration is a promising water treatment method due to its low energy consumption and low maintenance. However, the low stable permeability in algae-laden water treatment is currently limiting its wider application. With the ultimate goal of increasing permeability, the aim of this study was to evaluate the effect of a composite coagulant of aluminum sulfate-chitosan (AS-CS) on the GDM filtration performance. In parallel tests with a single AS coagulant and without pre-coagulation, the analysis of membrane fouling resistance and the membrane fouling mechanism were evaluated. The results indicated that the AS-CS/GDM system can alleviate 23.74% and 58.80% membrane fouling, respectively, compared with AS/GDM and the GDM system. The AS-CS/GDM system can effectively remove humic-like substances having a molecular weight (MW) of 3–100 kDa, resulting in removal of 98.32% of algae cells and removal of 66.25% of dissolved organic carbon; the AS-CS/GDM system thereby improved the concentration of attached biomass on the membrane surface with the stronger biodegradability of organic matters. The application of AS-CS pre-coagulation in the GDM process could enhance the proliferation of microorganisms and the removal of low molecular weight humic-like substances. Therefore, the AS-CS/GDM system is a potentially important approach for algae-laden water treatment.

Water ◽  
2019 ◽  
Vol 11 (1) ◽  
pp. 90 ◽  
Author(s):  
Fan Bu ◽  
Baoyu Gao ◽  
Qinyan Yue ◽  
Caiyu Liu ◽  
Wenyu Wang ◽  
...  

Ultra-filtration technology has been increasingly used in drinking water treatment due to improvements in membrane performance and lowering of costs. However, membrane fouling is the main limitation in the application of ultra-filtration technology. In this study, we investigated the impact of four different pre-treatments: Coagulation, adsorption, coagulation followed by adsorption (C-A), and simultaneous coagulation and adsorption (C+A), on membrane fouling and natural organic matter removal efficiency. The results showed that adsorption process required a large amount of adsorbent and formed a dense cake layer on the membrane surface leading to severe membrane fouling. Compared to adsorption alone, the coagulation and C-A processes decreased the transmembrane pressure by 4.9 kPa. It was due to less accumulation of particles on the membrane surface. As for water quality, the C-A ultra-filtration process achieved the highest removal efficiencies of natural organic matter and disinfection by-product precursors. Therefore, the addition of adsorbent after coagulation is a potentially important approach for alleviating ultra-filtration membrane fouling and enhancing treatment performance.


2020 ◽  
Vol 20 (4) ◽  
pp. 1453-1462
Author(s):  
Fangshu Qu ◽  
Xiaolian Li ◽  
Junguo He ◽  
Zhihui Pan ◽  
Yan Zhao ◽  
...  

Abstract Ultrafiltration (UF) is increasingly used for potable water treatment, but membrane fouling necessitates the application of periodical backwash, which increases running cost. A new backwash strategy, in which air scouring was only applied with sludge water discharging, was proposed to improve backwash performance in a water plant using UF. Four gravity-driven UF systems were simultaneously run at increasing air scouring intervals (3–24hours) and sludge water discharging intervals (12–24hours). The membrane fluxes were monitored to assess membrane fouling and the mix solution turbidity was also monitored to investigate deposition of particles. The results indicated that membrane fouling was not aggravated by the extension of air scouring and sludge water discharging intervals. Water backwash on its own induced a shift of particle deposition from the membrane surface to the bottom of the membrane tank due to limited cake layer breakage, enabling the extension of sludge water discharging intervals. For the gravity-driven system investigated, the running cost, including energy, water and chemical demand, was reduced by 16.67% as the air scouring and sludge water discharging intervals increased from 3hours to 24hours and from 12hours to 24hours, respectively.


2021 ◽  
Author(s):  
Amira Abdelrasoul

The low-pressure membrane applications are considered to be the most effective and sustainable methods of addressing environmental problems in treating water and wastewater that meets or exceed stringent environmental standards. Nevertheless, membrane fouling is one of the primary operational concerns that is currently hindering a more widespread application of ultrafiltration (UF) with a variety of contaminants. Membrane fouling leads to higher operating costs, higher energy demand, reduced membrane life time, and increased cleaning frequency. As a consequence, an efficient and well-planned UF process is becoming a necessity for consistent and long-term monetary returns. Examining the source and mechanisms of foulant attachment to the membrane’s surface is critical when it comes to the research of membrane fouling and its potential practical implementation. A mathematical model was developed in this study in order to predict the amount of fouling based on an analysis of particle attachments. This model was developed using both homogeneous and heterogeneous membranes, with a uniform and non-uniform pore sizes for the UF of simulated latex effluent with a wide range of particle size distribution. The objective of this mathematical model was to effectively identify and address the common shortcomings of previous fouling models, and to account for the existing chemical attachments in membrane fouling. The mathematical model resulting from this study was capable of accurately predicting the mass of fouling retained by the membrane and the increase in transmembrane pressure (TMP). In addition, predictive models of fouling attachments were derived and now form an extensive set of mathematical models necessary for the prediction of membrane fouling at a given operating condition, as well as, the various membrane surface charges. Polycarbonate and Polysulfone flat membranes, with pore sizes of 0.05 μm and a molecular weight cut off of 60,000 respectively, were used in the experimental designs under a constant feed flow rate and a cross-flow mode in UF of the simulated latex paint effluent. The TMP estimated from the model agreed with the experimentally measured values at different operating conditions, mostly within 5.0 - 8.0 % error, and up to 13.0% error for the uniform, and non-uniform pore size membranes, respectively. Furthermore, different types of membranes with a variety of molecular weight cut-off (MWCO) values were tested so as to evaluate the accuracy of the models for a generalized application. In addition , a power consumption model, incorporating fouling attachment as well as chemical and physical factors in membrane fouling, was developed in order to ensure accurate prediction and scale-up. Innovative remediation techniques were likewise developed and applied in order to minimize membrane fouling, enhance the membrane performance, and save energy. Fouling remediation methodologies included the pre-treating of the latex effluent, so as to limit its fouling propensity by using different types of surfactants as cationic and anionic, in addition to the pH change. The antifouling properties of the membranes were improved through the implementation of the membrane pH treatment and anionic surfactant treatment. Increasing the ionic strength of latex effluent or enhancing the membrane surface hydrophilicity facilitated a significant increase in the cumulative permeate flux, a substantial decrease in the total mass of fouling, and a noticeable decrease in the specific power consumption.


2021 ◽  
Author(s):  
Amira Abdelrasoul

The low-pressure membrane applications are considered to be the most effective and sustainable methods of addressing environmental problems in treating water and wastewater that meets or exceed stringent environmental standards. Nevertheless, membrane fouling is one of the primary operational concerns that is currently hindering a more widespread application of ultrafiltration (UF) with a variety of contaminants. Membrane fouling leads to higher operating costs, higher energy demand, reduced membrane life time, and increased cleaning frequency. As a consequence, an efficient and well-planned UF process is becoming a necessity for consistent and long-term monetary returns. Examining the source and mechanisms of foulant attachment to the membrane’s surface is critical when it comes to the research of membrane fouling and its potential practical implementation. A mathematical model was developed in this study in order to predict the amount of fouling based on an analysis of particle attachments. This model was developed using both homogeneous and heterogeneous membranes, with a uniform and non-uniform pore sizes for the UF of simulated latex effluent with a wide range of particle size distribution. The objective of this mathematical model was to effectively identify and address the common shortcomings of previous fouling models, and to account for the existing chemical attachments in membrane fouling. The mathematical model resulting from this study was capable of accurately predicting the mass of fouling retained by the membrane and the increase in transmembrane pressure (TMP). In addition, predictive models of fouling attachments were derived and now form an extensive set of mathematical models necessary for the prediction of membrane fouling at a given operating condition, as well as, the various membrane surface charges. Polycarbonate and Polysulfone flat membranes, with pore sizes of 0.05 μm and a molecular weight cut off of 60,000 respectively, were used in the experimental designs under a constant feed flow rate and a cross-flow mode in UF of the simulated latex paint effluent. The TMP estimated from the model agreed with the experimentally measured values at different operating conditions, mostly within 5.0 - 8.0 % error, and up to 13.0% error for the uniform, and non-uniform pore size membranes, respectively. Furthermore, different types of membranes with a variety of molecular weight cut-off (MWCO) values were tested so as to evaluate the accuracy of the models for a generalized application. In addition , a power consumption model, incorporating fouling attachment as well as chemical and physical factors in membrane fouling, was developed in order to ensure accurate prediction and scale-up. Innovative remediation techniques were likewise developed and applied in order to minimize membrane fouling, enhance the membrane performance, and save energy. Fouling remediation methodologies included the pre-treating of the latex effluent, so as to limit its fouling propensity by using different types of surfactants as cationic and anionic, in addition to the pH change. The antifouling properties of the membranes were improved through the implementation of the membrane pH treatment and anionic surfactant treatment. Increasing the ionic strength of latex effluent or enhancing the membrane surface hydrophilicity facilitated a significant increase in the cumulative permeate flux, a substantial decrease in the total mass of fouling, and a noticeable decrease in the specific power consumption.


2008 ◽  
Vol 57 (5) ◽  
pp. 773-779 ◽  
Author(s):  
Xianghua Wen ◽  
Pengzhe Sui ◽  
Xia Huang

In this study, ultrasound was applied to control membrane fouling development online in an anaerobic membrane bioreactor (AMBR). Experimental results showed that membrane fouling could be controlled effectively by ultrasound although membrane damage may occur under some operational conditions. Based upon the observation on the damaged membrane surface via SEM, two mechanisms causing membrane damage by exerting ultrasound are inferred as micro particle collide on the membrane surface and chemical interaction between membrane materials and hydroxyl radicals produced by acoustic cavitations. Not only membrane damage but also membrane fouling control and membrane fouling cleaning were resulted from these mechanisms. Properly selecting ultrasonic intensity and working time, and keeping a certain thickness of cake layer on membrane surface could be effective ways to protect membrane against damage.


Membranes ◽  
2020 ◽  
Vol 10 (7) ◽  
pp. 149 ◽  
Author(s):  
Bin Huang ◽  
Hangkun Gu ◽  
Kang Xiao ◽  
Fangshu Qu ◽  
Huarong Yu ◽  
...  

Membrane fouling is still the bottleneck affecting the technical and economic performance of the ultrafiltration (UF) process for the surface water treatment. It is very important to accurately understand fouling mechanisms to effectively prevent and control UF fouling. The rejection performance and fouling mechanisms of the UF membrane for raw and coagulated surface water treatment were investigated under the cycle operation of constant-pressure dead-end filtration and backwash. There was no significant difference in the UF permeate quality of raw and coagulated surface water. Coagulation mainly removed substances causing turbidity in raw surface water (including most suspended particles and a few organic colloids) and thus mitigated UF fouling effectively. Backwash showed limited fouling removal. For the UF process of both raw and coagulated surface water, the fittings using single models showed good linearity for multiple models mainly due to statistical illusions, while the fittings using combined models showed that only the combined complete blocking and cake layer model fitted well. The quantitative calculations showed that complete blocking was the main reason causing flux decline. Membrane fouling mechanism analysis based on combined models could provide theoretical supports to prevent and control UF fouling for surface water treatment.


Membranes ◽  
2020 ◽  
Vol 10 (9) ◽  
pp. 213
Author(s):  
Stéphane Venne ◽  
Onita D. Basu ◽  
Benoit Barbeau

Membrane fouling in surface waters impacted by cyanobacteria is currently poorly controlled and results in high operating costs. A chemically enhanced backwash (CEB) is one possible strategy to mitigate cyanobacteria fouling. This research investigates the potential of using an ozone CEB to control the fouling caused by Microcystis aeruginosa in filtered surface water on a ceramic ultrafiltration membrane. Batch ozonation tests and dead-end, continuous flow experiments were conducted with ozone doses between 0 and 19 mg O3/mg carbon. In all tests, the ozone was shown to react more rapidly with the filtered surface water foulants than with cyanobacteria. In addition, the ozone CEB demonstrated an improved mitigation of irreversible fouling over 2 cycles versus a single CEB cycle; indicating that the ozone CEB functioned better as the cake layer developed. Ozone likely weakens the compressible cake layer formed by cyanobacteria on the membrane surface during filtration, which then becomes more hydraulically reversible. In fact, the ozone CEB reduced the fouling resistance by 35% more than the hydraulic backwash when the cake was more compressed.


Membranes ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 643
Author(s):  
Hongjian Yu ◽  
Weipeng Huang ◽  
Huachen Liu ◽  
Tian Li ◽  
Nianping Chi ◽  
...  

The combination of conventional and advanced water treatment is now widely used in drinking water treatment. However, membrane fouling is still the main obstacle to extend its application. In this study, the impact of the combination of coagulation and ultrafiltration (UF) membrane rotation on both fouling control and organic removal of macro (sodium alginate, SA) and micro organic matters (tannic acid, TA) was studied comprehensively to evaluate its applicability in drinking water treatment. The results indicated that membrane rotation could generate shear stress and vortex, thus effectively reducing membrane fouling of both SA and TA solutions, especially for macro SA organics. With additional coagulation, the membrane fouling could be further reduced through the aggregation of mediate and macro organic substances into flocs and elimination by membrane retention. For example, with the membrane rotation speed of 60 r/min, the permeate flux increased by 90% and the organic removal by 35% in SA solution, with 40 mg/L coagulant dosage, with an additional 70% increase of flux and 5% increment of organic removal to 80% obtained. However, too much shear stress could intensify the potential of fiber breakage at the potting, destroying the flocs and resulting in the reduction of permeate flux and deterioration of effluent quality. Finally, the combination of coagulation and membrane rotation would lead to the shaking of the cake layer, which is beneficial for fouling mitigation and prolongation of membrane filtration lifetime. This study provides useful information on applying the combined process of conventional coagulation and the hydrodynamic shear force for drinking water treatment, which can be further explored in the future.


2019 ◽  
Vol 43 (23) ◽  
pp. 9280-9288 ◽  
Author(s):  
Lei Pu ◽  
Xing Wang ◽  
Kaiping Shang ◽  
Qiping Cao ◽  
Si Gao ◽  
...  

A kind of non-precious glass bead catalyst was prepared by a subcritical water treatment method for the depolymerisation of poplar lignin.


Sign in / Sign up

Export Citation Format

Share Document