scholarly journals Nitrification in Premise Plumbing: A Review

Water ◽  
2020 ◽  
Vol 12 (3) ◽  
pp. 830 ◽  
Author(s):  
Tyler C. Bradley ◽  
Charles N. Haas ◽  
Christopher M. Sales

Nitrification is a major issue that utilities must address if they utilize chloramines as a secondary disinfectant. Nitrification is the oxidation of free ammonia to nitrite which is then further oxidized to nitrate. Free ammonia is found in drinking water systems as a result of overfeeding at the water treatment plant (WTP) or as a result of the decomposition of monochloramine. Premise plumbing systems (i.e., the plumbing systems within buildings and homes) are characterized by irregular usage patterns, high water age, high temperature, and high surface-to-volume ratios. These characteristics create ideal conditions for increased chloramine decay, bacterial growth, and nitrification. This review discusses factors within premise plumbing that are likely to influence nitrification, and vice versa. Factors influencing, or influenced by, nitrification include the rate at which chloramine residual decays, microbial regrowth, corrosion of pipe materials, and water conservation practices. From a regulatory standpoint, the greatest impact of nitrification within premise plumbing is likely to be a result of increased lead levels during Lead and Copper Rule (LCR) sampling. Other drinking water regulations related to nitrifying parameters are monitored in a manner to reduce premise plumbing impacts. One way to potentially control nitrification in premise plumbing systems is through the development of building management plans.

RSC Advances ◽  
2016 ◽  
Vol 6 (80) ◽  
pp. 76922-76932 ◽  
Author(s):  
Bingwei Hou ◽  
Tao Lin ◽  
Wei Chen

Recycling the filter backwash water of a drinking water treatment plant (DWTP) was considered as a feasible method to enhance the efficiencies of pollutant removal and water conservation.


1994 ◽  
Vol 30 (10) ◽  
pp. 221-227 ◽  
Author(s):  
Jordi Martín-Alonso

The Llobregat is a 156 km long river, which supplies 35% of the Barcelona's drinking water needs from the Sant Joan Despí Water Treatment Plant. Since the establishment of the Salt Mine Works in the Llobregat basin in 1923, a progressive salinization of the water sources has been recorded. The operation of the Brine Collector, as a public work carried out by Aigües de Barcelona (AGBAR), started in 1989; it enabled a very significant improvement in the quality of the surface water used for drinking-water production.


2016 ◽  
Vol 16 (4) ◽  
pp. 922-930 ◽  
Author(s):  
L. Richard ◽  
E. Mayr ◽  
M. Zunabovic ◽  
R. Allabashi ◽  
R. Perfler

The implementation and evaluation of biological nitrification as a possible treatment option for the small-scale drinking water supply of a rural Upper Austrian community was investigated. The drinking water supply of this community (average system input volume: 20 m3/d) is based on the use of deep anaerobic groundwater with a high ammonium content of geogenic origin (up to 5 mg/l) which must be treated to prevent the formation of nitrites in the drinking water supply system. This paper describes the implementation and operation of biological nitrification despite several constraints including space availability, location and financial and manpower resources. A pilot drinking water treatment plant, including biological nitrification implemented in sand filters, was designed and constructed for a maximum treatment capacity of 1.2 m3/h. Online monitoring of selected physicochemical parameters has provided continuous treatment performance data. Treatment performance of the plant was evaluated under standard operation as well as in the case of selected malfunction events.


2017 ◽  
Vol 29 (12) ◽  
pp. 2665-2670
Author(s):  
Soleha Mohamat Yusuff ◽  
K.K. Ong ◽  
W.M.Z. Wan Yunus ◽  
A. Fitrianto ◽  
M. Ahmad ◽  
...  

Author(s):  
Ivone Vaz-Moreira ◽  
Vânia Figueira ◽  
Ana R. Lopes ◽  
Alexandre Lobo-da-Cunha ◽  
Cathrin Spröer ◽  
...  

A Gram-positive, aerobic, non-motile, endospore-forming rod, designated DS22T, was isolated from a drinking-water treatment plant. Cells were catalase- and oxidase-positive. Growth occurred at 15–37 °C, at pH 7–10 and with <8 % (w/v) NaCl (optimum growth: 30 °C, pH 7–8 and 1–3 % NaCl). The major respiratory quinone was menaquinone 7, the G+C content of the genomic DNA was 36.5 mol% and the cell wall contained meso-diaminopimelic acid. On the basis of 16S rRNA gene sequence analysis, strain DS22T was a member of the genus Bacillus. Its closest phylogenetic neighbours were Bacillus horneckiae NRRL B-59162T (98.5 % 16S rRNA gene sequence similarity), Bacillus oceanisediminis H2T (97.9 %), Bacillus infantis SMC 4352-1T (97.4 %), Bacillus firmus IAM 12464T (96.8 %) and Bacillus muralis LMG 20238T (96.8 %). DNA–DNA hybridization, and biochemical and physiological characterization allowed the differentiation of strain DS22T from its closest phylogenetic neighbours. The data supports the proposal of a novel species, Bacillus purgationiresistans sp. nov.; the type strain is DS22T ( = DSM 23494T = NRRL B-59432T = LMG 25783T).


Sign in / Sign up

Export Citation Format

Share Document