scholarly journals Reliability Analysis of Activated Sludge Process by Means of Biokinetic Modelling and Simulation Results

Water ◽  
2020 ◽  
Vol 12 (1) ◽  
pp. 291 ◽  
Author(s):  
Dariusz Andraka

Analysis of wastewater treatment plant reliability is a difficult process, therefore it is often limited to selected aspects, e.g., mechanical reliability of equipment or technological availability of the process. The research presents a method of combining the above mentioned aspects in order to determine the complex operational availability index (CAVO). A hypothetical technological system with activated sludge (AS) in a typical layout (denitrification-nitrification) was selected for the studies. A number of operational scenarios have been developed, taking into account the possible mechanical failures of system components. Computer simulations with the use of Activated Sludge Model No.1 (ASM1), performed for selected scenarios allowed the determination of a complex operational availability of the system. Obtained results confirm high reliability of AS system in terms of biochemical oxygen demand (BOD), chemical oxygen demand (COD) and total suspended solids (TSS) removal (CAVO > 0.96) and indicate the necessity of further research in order to determine representative value of reliability of total nitrogen removal (from the study, CAVO-Ntot < 0.4) and to evaluate other technological solutions in terms of their complex reliability.

2012 ◽  
Vol 7 (1) ◽  
Author(s):  
S. S. Fatima ◽  
S. Jamal Khan

In this study, the performance of wastewater treatment plant located at sector I-9 Islamabad, Pakistan, was evaluated. This full scale domestic wastewater treatment plant is based on conventional activated sludge process. The parameters which were monitored regularly included total suspended solids (TSS), mixed liquor suspended solids (MLSS), mixed liquor volatile suspended solids (MLVSS), biological oxygen demand (BOD), and chemical oxygen demand (COD). It was found that the biological degradation efficiency of the plant was below the desired levels in terms of COD and BOD. Also the plant operators were not maintaining consistent sludge retention time (SRT). Abrupt discharge of MLSS through the Surplus Activated sludge (SAS) pump was the main reason for the low MLSS in the aeration tank and consequently low treatment performance. In this study the SRT was optimized based on desired MLSS concentration between 3,000–3,500 mg/L and required performance in terms of BOD, COD and TSS. This study revealed that SRT is a very important operational parameter and its knowledge and correct implementation by the plant operators should be mandatory.


2020 ◽  
Vol 12 (19) ◽  
pp. 8182
Author(s):  
Nuhu Dalhat Mu’azu ◽  
Omar Alagha ◽  
Ismail Anil

Mathematical modeling has become an indispensable tool for sustainable wastewater management, especially for the simulation of complex biochemical processes involved in the activated sludge process (ASP), which requires a substantial amount of data related to wastewater and sludge characteristics as well as process kinetics and stoichiometry. In this study, a systematic approach for calibration of the activated sludge model one (ASM1) model for a real municipal wastewater ASP was undertaken in GPS-X. The developed model was successfully validated while meeting the assumption of the model’s constant stoichiometry and kinetic coefficients for any plant influent compositions. The influences of vital ASP parameters on the treatment plant performance and capacity analysis for meeting local discharge limits were also investigated. Lower influent chemical oxygen demand in mgO2/L (COD) could inhibit effective nitrification and denitrification, while beyond 250 mgO2/L, there is a tendency for effluent quality to breach the regulatory limit. The plant performance can be satisfactory for handling even higher influent volumes up to 60,000 m3/d and organic loading when Total Suspended Solids/Volatile Suspended Solids (VSS/TSS) and particulate COD (XCOD)/VSS are maintained above 0.7 and 1, respectively. The wasted activated sludge (WAS) has more impact on the effluent quality compared to recycle activated sludge (RAS) with significant performance improvement when the WAS was increased from 3000 to 9000 m3/d. Hydraulic retention time (HRT) > 6 h and solids retention time (SRT) < 7 days resulted in better plant performance with the SRT having greater impact compared with HRT. The plant performance could be sustained for a quite appreciable range of COD/5-day Biochemical Oxygen Demand (BOD5 in mgO2/L) ratio, Mixed Liquor Suspended Solid (MLSS) of up to 6000 mg/L, and when BOD5/total nitrogen (TN) and COD/TN are comparatively at higher values. This work demonstrated a systematic approach for estimation of the wastewater treatment plant (WWTP) ASP parameters and the high modeling capabilities of ASM1 in GPS-X when respirometry tests data are lacking.


1970 ◽  
Vol 5 (1) ◽  
pp. 34-54
Author(s):  
Shyam D. Bokil ◽  
Jatinder K. Bewtra

Abstract Nine sets of batch experiments, each of ten to twelve days duration, were conducted in the laboratory on return-sludge samples collected from activated sludge treatment plant at Windsor. The thickened sludge samples were blended daily in a waring blender and were continuously aerated in twelve-litres capacity jars. Parallel runs were made on control sludge samples which were not blended. Amongst the parameters varied were the speed and frequency of blending and the aeration rate. The effects of these variables on progressive bio-degradation of volatile suspended solids and the settling characteristics of the sludge were determined. Blended sludge showed significant improvement in the rate of bio-degradation and its settling characteristics as compared to the control unblended sludge


1988 ◽  
Vol 20 (1) ◽  
pp. 65-72 ◽  
Author(s):  
Rurik Skogman ◽  
Reino Lammi

The requirements imposed on the Finnish forest products industry by the water authorities have focused on the reduction of BOD and suspended solids in the wastewaters. The industry has tried to comply with these requirements, first through internal measures such as process changes and closed systems. When these have not been sufficient, external treatment has been resorted to. The Wilh. Schauman Company in Jakobstad has chosen activated sludge with extended aeration from among the available methods for treating effluent. The plant has operated since the beginning of 1986 with extremely good results. In addition to the reduction of BOD and suspended solids, there has been a marked decrease of chlorinated phenols. Chlorinated substances with higher molecular weight are also removed during the process.


2008 ◽  
Vol 57 (8) ◽  
pp. 1287-1293 ◽  
Author(s):  
A. Jobbágy ◽  
G. M. Tardy ◽  
Gy. Palkó ◽  
A. Benáková ◽  
O. Krhutková ◽  
...  

The purpose of the experiments was to increase the rate of activated sludge denitrification in the combined biological treatment system of the Southpest Wastewater Treatment Plant in order to gain savings in cost and energy and improve process efficiency. Initial profile measurements revealed excess denitrification capacity of the preclarified wastewater. As a consequence, flow of nitrification filter effluent recirculated to the anoxic activated sludge basins was increased from 23,000 m3 d−1 to 42,288 m3 d−1 at an average preclarified influent flow of 64,843 m3 d−1, Both simulation studies and microbiological investigations suggested that activated sludge nitrification, achieved despite the low SRT (2–3 days), was initiated by the backseeding from the nitrification filters and facilitated by the decreased oxygen demand of the influent organics used for denitrification. With the improved activated sludge denitrification, methanol demand could be decreased to about half of the initial value. With the increased efficiency of the activated sludge pre-denitrification, plant effluent COD levels decreased from 40–70 mg l−1 to &lt; 30–45 mg l−1 due to the decreased likelihood of methanol overdosing in the denitrification filter


2017 ◽  
Vol 77 (1) ◽  
pp. 70-78 ◽  
Author(s):  
Yanjun Mao ◽  
Xie Quan ◽  
Huimin Zhao ◽  
Yaobin Zhang ◽  
Shuo Chen ◽  
...  

Abstract The activated sludge (AS) process is widely applied in dyestuff wastewater treatment plants (WWTPs); however, the nitrogen removal efficiency is relatively low and the effluent does not meet the indirect discharge standards before being discharged into the industrial park's WWTP. Hence it is necessary to upgrade the WWTP with more advanced technologies. Moving bed biofilm processes with suspended carriers in an aerobic tank are promising methods due to enhanced nitrification and denitrification. Herein, a pilot-scale integrated free-floating biofilm and activated sludge (IFFAS) process was employed to investigate the feasibility of enhancing nitrogen removal efficiency at different hydraulic retention times (HRTs). The results showed that the effluent chemical oxygen demand (COD), ammonium nitrate (NH4+-N) and total nitrogen (TN) concentrations of the IFFAS process were significantly lower than those of the AS process, and could meet the indirect discharge standards. PCR-DGGE and FISH results indicated that more nitrifiers and denitrifiers co-existed in the IFFAS system, promoting simultaneous nitrification and denitrification. Based on the pilot results, the IFFAS process was used to upgrade the full-scale AS process, and the effluent COD, NH4+-N and TN of the IFFAS process were 91–291 mg/L, 10.6–28.7 mg/L and 18.9–48.6 mg/L, stably meeting the indirect discharge standards and demonstrating the advantages of IFFAS in dyestuff wastewater treatment.


2017 ◽  
Vol 13 (2) ◽  
Author(s):  
B Vivekanandan ◽  
K Jeyannathann ◽  
A. Seshagiri Rao

Abstract The quality of a treated effluent changes when there is a sudden variation in the influent flow to the wastewater treatment plant during dry, rain, and storm weather conditions. In this study, various influent flow conditions in an activated sludge process are considered that affect the sensitivity of effluent variables such as chemical oxygen demand (COD), biological oxygen demand (BOD), nitrate nitrogen (SNO), ammonical nitrogen (SNH), and total nitrogen (TN) with respect to varying internal recycle flow rate (Qa), sludge recycle flow rate (Qr), sludge wastage flow rate (Qw) and oxygen transfer rate co-efficient of aerobic tanks (KLa(3,4,5)). The analysis has been carried out based on benchmark simulation model no.1 (BSM 1) plant layout which comprises of two models namely activated sludge model no.1 (ASM 1) and simple one dimensional (Simple 1-D) Takacs model. Based on the present analysis, it is observed that the changes in influent flow rate have larger impact on the effluent variables. This variation can be subdued by introducing additional tanks to smoothen the perturbations or using internal recycle rate from the fifth tank in order to maintain the flow around the optimal influent flow rate. The sludge wastage rate has a greater impact on all effluent variables except nitrogenous variables during maximum flow conditions.


Water ◽  
2020 ◽  
Vol 12 (10) ◽  
pp. 2657
Author(s):  
Elwira Nowobilska-Majewska ◽  
Piotr Bugajski

The aim of this study was to determine the condition of activated sludge in the biologic reactor located in the collective wastewater treatment plant in Nowy Targ (Poland) based on OUR tests in the aspect of the impact of sludge’s concentration in the biologic reactor and dependence of BOD5/TN and BOD5/TP in wastewater flowing into the biologic reactor. The analysis was conducted based on test results from 61 samples of activated sludge taken from the biologic reactor and 61 samples of wastewater flowing into the biologic reactor. The analysis included the concentration of sludge in the biologic reactor. The following indicators were analyzed in wastewater flowing into the reactor: biochemical oxygen demand (BOD5), total nitrogen (TN) and total phosphorus (TP). The statistical analysis concerning the impact of the analyzed factors on oxygen uptake rate (OUR) tests was developed based on the Pearson’s correlation coefficient and partial correlation of many variables. Based on the results of the partial correlation analysis, nomograms were developed to determine the condition of activated sludge microorganisms (OUR) based on the BOD5/TN and BOD5/TP connection and knowledge of the sludge concentration in the bioreactor of the treatment plant. The presented nomograms can be formulated for each bioreactor based on activated sludge technology related the load of organic and biogenic pollutants in the wastewater flowing into the bioreactor and the concentration of the sludge in the bioreactor.


Water ◽  
2018 ◽  
Vol 10 (10) ◽  
pp. 1445 ◽  
Author(s):  
Michał Marzec ◽  
Krzysztof Jóźwiakowski ◽  
Anna Dębska ◽  
Magdalena Gizińska-Górna ◽  
Aneta Pytka-Woszczyło ◽  
...  

In this paper, the pollutant removal efficiency and the reliability of a vertical and horizontal flow hybrid constructed wetland (CW) planted with common reed, manna grass, and Virginia mallow were analyzed. The wastewater treatment plant, located in south-eastern Poland, treated domestic sewage at an average flow rate of 2.5 m3/d. The tests were carried out during five years of its operation (2014–2018). The following parameters were measured: biochemical oxygen demand (BOD5), chemical oxygen demand (COD), total suspended solids, total nitrogen, and total phosphorus. The results showed that more than 95% of BOD5, COD, and total phosphorus was removed in the tested CW system. The average effectiveness of removal of total suspended solids and total nitrogen exceeded 86%. A reliability analysis performed using the Weibull probability model showed that the removal reliability in the tested CW was very high for BOD5, COD, total suspended solids, and total phosphorus (100%). The probability that the total nitrogen concentration in the treated effluents would reach the limit value (30 mg/L) established for effluents discharged from a treatment plant of less than 2000 PE (population equivalent) to standing waters was 94%. The values of all the pollution indicators in wastewater discharged to the receiver were significantly lower than the limit values required in Poland. The investigated hybrid CW system with common reed, manna grass, and Virginia mallow guaranteed stable low values of BOD5, COD, total suspended solids, and total phosphorus in the treated wastewater, which meant it was highly likely to be positively evaluated in case of an inspection.


Sign in / Sign up

Export Citation Format

Share Document