scholarly journals Concentration Detection of the E. coli Bacteria in Drinking Water Treatment Plants through an E-Nose and a Volatiles Extraction System (VES)

Water ◽  
2019 ◽  
Vol 11 (4) ◽  
pp. 774
Author(s):  
Jeniffer Carrillo-Gómez ◽  
Cristhian Durán-Acevedo ◽  
Ramón García-Rico

Water quality control remains an important topic of public health since some diseases, such as diarrhea, hepatitis, and cholera, are caused by its consumption. The microbiological quality of drinking water relies mainly on monitoring of Escherichia coli, a bacteria indicator which serves as an early sentinel of potential health hazards for the population. In this study, an electronic nose coupled to a volatile extraction system (was evaluated for the detection of the emitted compounds by E. coli in water samples where its capacity for the quantification of the bacteria was demonstrated). To achieve this purpose, the multisensory system was subjected to control samples for training. Later, it was tested with samples from drinking water treatment plants in two locations of Colombia. For the discrimination and classification of the water samples, the principal component analysis method was implemented obtaining a discrimination variance of 98.03% of the measurements to different concentrations. For the validation of the methodology, the membrane filtration technique was used. In addition, two classification methods were applied to the dataset where a success rate of 90% of classification was obtained using the discriminant function analysis and having a probabilistic neural network coupled to the cross-validation technique (leave-one-out) where a classification rate of 80% was obtained. The application of this methodology achieved an excellent classification of the samples, discriminating the free samples of E. coli from those that contained the bacteria. In the same way, it was observed that the system could correctly estimate the concentration of this bacteria in the samples. The proposed method in this study has a high potential to be applied in the determination of E. coli in drinking water since, in addition for estimating concentration ranges and having the necessary sensitivity, it significantly reduces the time of analysis compared to traditional methods.

2009 ◽  
Vol 28 (2) ◽  
pp. 133-134 ◽  
Author(s):  
Elisabet Teixidó ◽  
Jesús Gómez-Catalán ◽  
Javier González-Linares ◽  
Miquel Borràs ◽  
Joan M. Llobet

Author(s):  
Wonjin Sim ◽  
Sol Choi ◽  
Gyojin Choo ◽  
Mihee Yang ◽  
Ju-Hyun Park ◽  
...  

In this study, the concentrations of organophosphate flame retardants (OPFR) and perfluoroalkyl substances (PFAS) were investigated in raw water and treated water samples obtained from 18 drinking water treatment plants (DWTPs). The ∑13OPFR concentrations in the treated water samples (29.5–122 ng/L; median 47.5 ng/L) were lower than those in the raw water (37.7–231 ng/L; median 98.1 ng/L), which indicated the positive removal rates (0–80%) of ∑13OPFR in the DWTPs. The removal efficiencies of ∑27PFAS in the DWTPs ranged from −200% to 50%, with the ∑27PFAS concentrations in the raw water (4.15–154 ng/L; median 32.0 ng/L) being similar to or lower than those in the treated water (4.74–116 ng/L; median 42.2 ng/L). Among OPFR, tris(chloroisopropyl) phosphate (TCIPP) and tris(2-chloroethyl) phosphate (TCEP) were dominant in both raw water and treated water samples obtained from the DWTPs. The dominant PFAS (perfluorooctanoic acid (PFOA) and perfluorohexanoic acid (PFHxA)) in the raw water samples were slightly different from those in the treated water samples (PFOA, L-perfluorohexane sulfonate (L-PFHxS), and PFHxA). The 95-percentile daily intakes of ∑13OPFR and ∑27PFAS via drinking water consumption were estimated to be up to 4.9 ng/kg/d and 0.22 ng/kg/d, respectively. The hazard index values of OPFR and PFAS were lower than 1, suggesting the risks less than known hazardous levels.


2014 ◽  
Vol 71 (4) ◽  
pp. 597-604 ◽  
Author(s):  
Sabrina Sorlini ◽  
Maria Cristina Collivignarelli ◽  
Federico Castagnola ◽  
Barbara Marianna Crotti ◽  
Massimo Raboni

Critical barriers to safe and secure drinking water may include sources (e.g. groundwater contamination), treatments (e.g. treatment plants not properly operating) and/or contamination within the distribution system (infrastructure not properly maintained). The performance assessment of these systems, based on monitoring, process parameter control and experimental tests, is a viable tool for the process optimization and water quality control. The aim of this study was to define a procedure for evaluating the performance of full-scale drinking water treatment plants (DWTPs) and for defining optimal solutions for plant upgrading in order to optimize operation. The protocol is composed of four main phases (routine and intensive monitoring programmes – Phases 1 and 2; experimental studies – Phase 3; plant upgrade and optimization – Phase 4). The protocol suggested in this study was tested in a full-scale DWTP placed in the North of Italy (Mortara, Pavia). The results outline some critical aspects of the plant operation and permit the identification of feasible solutions for the DWTP upgrading in order to optimize water treatment operation.


2017 ◽  
Vol 2017 ◽  
pp. 1-9 ◽  
Author(s):  
Lesley Maurice Bilung ◽  
Ahmad Syatir Tahar ◽  
Nur Emyliana Yunos ◽  
Kasing Apun ◽  
Yvonne Ai-Lian Lim ◽  
...  

Cryptosporidiosis and cyclosporiasis are caused by waterborne coccidian protozoan parasites of the generaCryptosporidiumandCyclospora,respectively. This study was conducted to detectCryptosporidiumandCyclosporaoocysts from environmental water abstracted by drinking water treatment plants and recreational activities in Sarawak, Malaysia. Water samples (12 each) were collected from Sungai Sarawak Kanan in Bau and Sungai Sarawak Kiri in Batu Kitang, respectively. In addition, 6 water samples each were collected from Ranchan Recreational Park and UNIMAS Lake at Universiti Malaysia Sarawak, Kota Samarahan, respectively. Water physicochemical parameters were also recorded. All samples were concentrated by the iron sulfate flocculation method followed by the sucrose floatation technique.CryptosporidiumandCyclosporawere detected by modified Ziehl-Neelsen technique. Correlation of the parasites distribution with water physicochemical parameters was analysed using bivariate Pearson correlation. Based on the 24 total samples of environmental water abstracted by drinking water treatment plants, all the samples (24/24; 100%) were positive withCryptosporidium, and only 2 samples (2/24; 8.33%) were positive withCyclospora. Based on the 12 total samples of water for recreational activities, 4 samples (4/12; 33%) were positive withCryptosporidium, while 2 samples (2/12; 17%) were positive withCyclospora.Cryptosporidiumoocysts were negatively correlated with dissolved oxygen (DO).


1986 ◽  
Vol 21 (3) ◽  
pp. 447-459 ◽  
Author(s):  
K.J. Roberts ◽  
R.B. Hunsinger ◽  
A.H. Vajdic

Abstract The Drinking Water Surveillance Program (DWSP), developed by the Ontario Ministry of the Environment, is an assessment project based on standardized analytical and sampling protocol. This program was recently instituted in response to a series of contaminant occurrences in the St. Clair-Detroit River area of Southwestern Ontario. This paper outlines the details and goals of the program and provides information concerning micro-contaminants in drinking water at seven drinking water treatment plants in Southwestern Ontario.


Author(s):  
Samantha Donovan ◽  
Ariel Jasmine Atkinson ◽  
Natalia Fischer ◽  
Amelia E Taylor ◽  
Johann Kieffer ◽  
...  

PolyDiallyldimethyl Ammonium Chloride (PolyDADMAC) is the most commonly used polymer at drinking water treatment plants and has the potential to form nitrosamines, like N-Nitrosodimethylamine (NDMA), if free polymer is present...


2000 ◽  
Vol 46 (6) ◽  
pp. 565-576 ◽  
Author(s):  
Pierre Payment ◽  
Aminata Berte ◽  
Michèle Prévost ◽  
Bruno Ménard ◽  
Benoît Barbeau

A 300-km portion of the Saint Lawrence hydrological basin in the province of Québec (Canada) and 45 water treatment plants were studied. River water used by drinking water treatment plants was analyzed (6-L sample volumes) to determine the level of occurrence of bacterial indicators (total coliforms, fecal coliforms, and Clostridium perfringens) and pathogens (Giardia lamblia, Cryptosporidium, human enteric viruses). Pathogens and bacterial indicators were found at all sites at a wide range of values. Logistic regression analysis revealed significant correlations between the bacterial indicators and the pathogens. Physicochemical and treatment practices data were collected from most water treatment plants and used to estimate the level of removal of pathogens achieved under cold (0°C-4°C) and warm (20°C-25°C) water temperature conditions. The calculated removal values were then used to estimate the annual risk of Giardia infection using mathematical models and to compare the sites. The estimated range of probability of infection ranged from 0.75 to less than 0.0001 for the populations exposed. Given the numerous assumptions made, the model probably overestimated the annual risk, but it provided comparative data of the efficacy of the water treatment plants and thereby contributes to the protection of public health.Key words: public health, drinking water, health risk, pathogen occurrence.