scholarly journals Modeling of Pollutants Removal in Subsurface Vertical Flow and Horizontal Flow Constructed Wetlands

Water ◽  
2019 ◽  
Vol 11 (1) ◽  
pp. 180 ◽  
Author(s):  
Wojciech Dąbrowski ◽  
Beata Karolinczak ◽  
Paweł Malinowski ◽  
Dariusz Boruszko

Reject water is a by-product of every municipal and agro-industrial wastewater treatment plant (WWTP) applying sewage sludge stabilization. It is usually returned without pre-treatment to the biological part of WWTP, having a negative impact on the nitrogen removal process. The current models of pollutants removal in constructed wetlands concern municipal and industrial wastewater, whereas there is no such model for reject water. In the presented study, the results of treatment of reject water from dairy WWTP in subsurface vertical flow (SS VF) and subsurface horizontal flow (SS HF) beds were presented. During a one-year research period, SS VF bed reached 50.7% efficiency of TN removal and 73.8% of NH4+-N, while SS HF bed effectiveness was at 41.4% and 62.0%, respectively. In the case of BOD5 (biochemical oxygen demand), COD (chemical oxygen demand), NH4+-N, and TN (total nitrogen), the P-k-C* model was applied. Multi-model nonlinear segmented regression analysis was performed. Final mathematical models with estimates of parameters determining the treatment effectiveness were obtained. Treatment efficiency increased up to the specific temperature, then it was constant. The results obtained in this work suggest that it may be possible to describe pollutant removal behavior using simplified models. In the case of TP (total phosphorus) removal, distribution tests along with a t-test were performed. All models predict better treatment efficiency in SS VF bed, except for TP.

2017 ◽  
Vol 76 (6) ◽  
pp. 1300-1307 ◽  
Author(s):  
Mao Liu ◽  
Boyuan Li ◽  
Yingwen Xue ◽  
Hongyu Wang ◽  
Kai Yang

To investigate the feasibility of using corncob charcoal substrate in constructed wetlands, four laboratory-scale vertical flow constructed wetlands (VFCWs) were built. Effluent pollutant (chemical oxygen demand (COD), NH4+-N, total phosphorus (TP)) concentrations during the experiment were determined to reveal pollutant removal mechanisms and efficiencies at different stages. In the stable stage, a VFCW using clay ceramisite substrate under aeration attained higher COD (95.1%), and NH4+-N (95.1%) removal efficiencies than a VFCW using corncob charcoal substrate (91.5% COD, 91.3% NH4+-N) under aeration, but lower TP removal efficiency (clay ceramisite 32.0% and corncob charcoal 40.0%). The VFCW with raw corncob substrate showed stronger COD emissions (maximum concentration 3,108 mg/L) than the corncob charcoal substrate (COD was lower than influent). The VFCW using corncob charcoal substrate performed much better than the VFCW using clay ceramisite substrate under aeration when the C/N ratio was low (C/N = 1.5, TN removal efficiency 36.89%, 4.1% respectively). These results suggest that corncob charcoal is a potential substrate in VFCWs under aeration with a unique self –supplying carbon source property in the denitrification process.


2015 ◽  
Vol 71 (9) ◽  
pp. 1333-1339 ◽  
Author(s):  
A. Morvannou ◽  
N. Forquet ◽  
S. Michel ◽  
S. Troesch ◽  
P. Molle

Approximately 3,500 constructed wetlands (CWs) provide raw wastewater treatment in France for small communities (<5,000 people equivalent). Built during the past 30 years, most consist of two vertical flow constructed wetlands (VFCWs) in series (stages). Many configurations exist, with systems associated with horizontal flow filters or waste stabilization ponds, vertical flow with recirculation, partially saturated systems, etc. A database analyzed 10 years earlier on the classical French system summarized the global performances data. This paper provides a similar analysis of performance data from 415 full-scale two-stage VFCWs from an improved database expanded by monitoring data available from Irstea and the French technical department. Trends presented in the first study are confirmed, exhibiting high chemical oxygen demand (COD), total suspended solids (TSS) and total Kjeldahl nitrogen (TKN) removal rates (87%, 93% and 84%, respectively). Typical concentrations at the second-stage outlet are 74 mgCOD L−1, 17 mgTSS L−1 and 11 mgTKN L−1. Pollutant removal performances are summarized in relation to the loads applied at the first treatment stage. While COD and TSS removal rates remain stable over the range of applied loads, the spreading of TKN removal rates increases as applied loads increase.


2017 ◽  
Vol 76 (1) ◽  
pp. 124-133 ◽  
Author(s):  
Ania Morvannou ◽  
Stéphane Troesch ◽  
Dirk Esser ◽  
Nicolas Forquet ◽  
Alain Petitjean ◽  
...  

French vertical flow constructed wetlands (VFCW) treating raw wastewater have been developed successfully over the last 30 years. Nevertheless, the two-stage VFCWs require a total filtration area of 2–2.5 m2/P.E. Therefore, implementing a one-stage system in which treatment performances reach standard requirements is of interest. Biho-Filter® is one of the solutions developed in France by Epur Nature. Biho-Filter® is a vertical flow system with an unsaturated layer at the top and a saturated layer at the bottom. The aim of this study was to assess this new configuration and to optimize its design and operating conditions. The hydraulic functioning and pollutant removal efficiency of three different Biho-Filter® plants commissioned between 2011 and 2012 were studied. Outlet concentrations of the most efficient Biho-Filter® configuration are 70 mg/L, 15 mg/L, 15 mg/L and 25 mg/L for chemical oxygen demand (COD), 5-day biological oxygen demand (BOD5), total suspended solids (TSS) and total Kjeldahl nitrogen (TKN), respectively. Up to 60% of total nitrogen is removed. Nitrification efficiency is mainly influenced by the height of the unsaturated zone and the recirculation rate. The optimum recirculation rate was found to be 100%. Denitrification in the saturated zone works at best with an influent COD/NO3-N ratio at the inflet of this zone larger than 2 and a hydraulic retention time longer than 0.75 days.


2017 ◽  
Vol 34 (1) ◽  
pp. 233-240 ◽  
Author(s):  
Katarzyna Skrzypiecbcef ◽  
Magdalena H. Gajewskaad

Abstract Constructed wetlands are characterized by specific conditions enabling simultaneous various physical and biochemical processes. This is the result of specific environment for the growth of microorganisms and hydrophytes (aquatic and semiaquatic plants) which are capable of living in aerobic, anaerobic and facultative anaerobic conditions. Their interaction contributes to the intensification of oxidation and reduction responsible for the removal and retention of pollutants. These processes are supported by sorption, sedimentation and assimilation. Thanks to these advantages, treatment wetland systems have been used in communal management for over 50 years. In recent years, thanks to its advantages, low operational costs and high removal efficiency, there is growing interest in the use of constructed wetlands for the treatment or pre-treatment of various types of industrial wastewater. The study analyzes current use of these facilities for the treatment of industrial wastewater in the world. The conditions of use and efficiency of pollutants removal from readily and slowly biodegradable wastewater, with special emphasis on specific and characteristic pollutants of particular industries were presented. The use of subsurface horizontal flow beds for the treatment of industrial wastewater, among others from crude oil processing, paper production, food industry including wineries and distillery, olive oil production and coffee processing was described. In Poland constructed wetlands are used for the treatment of sewage and sludge from milk processing in pilot scale or for dewatering of sewage sludge produced in municipal wastewater treatment plant treating domestic sewage with approximately 40% share of wastewater from dairy and fish industry. In all cases, constructed wetlands provided an appropriate level of treatment and in addition the so-called ecosystem service.


2011 ◽  
Vol 356-360 ◽  
pp. 1189-1194
Author(s):  
Chao Ma ◽  
Hui Ding ◽  
Yi Chao Sun ◽  
Xiao Wen Deng

In order to find the best substrates of constructed wetlands for saline waste sewage treatment, Bio-ceramic, quartz sand, zeolite and medical stone were used as filtering media for saline sewage treatment with proper proportion microbe, isolated from the sewage of the Wuqing sewage treatment plant. In this paper, the purification of the vertical-flow constructed wetlands (VFCWs) with different substrates was studied, and the component of the nitrogen in the influent and effluent was analyzed. The concentrations of chemical oxygen demand (COD), ammonia (NH4+-N), total phosphorus (TP), total nitrogen (TN) and the salinity of the influent during the experimental period were 150mg•L-1, 36 mg•L-1, 8mg•L-1, 36mg•L-1and 1.6%. Under the condition that the hydraulic loading rate was 0.25m•d-1, the average removal efficiency of COD, TP and TN were obtained about 68.81%, 32.01% and 20.72 %, respectively with Bio-ceramic; 61.92%, 31.75% and 34.33%, respectively with quartz sands; 69.47%, 35.44% and 55.28% , respectively with zeolite; and 64.77%, 32.63% and 34.72%, respectively with medical stone. This result proves that comprehensive purification of the system with zeolite is the best.


Author(s):  
Manoj Kumar ◽  
Rajesh Singh

In the present study area-based, pollutant removal kinetic analysis was considered using the Zero-order, first-order decay and efficiency loss (EL) models in the constructed wetlands (CWs) for municipal wastewater treatment....


2001 ◽  
Vol 44 (11-12) ◽  
pp. 137-142 ◽  
Author(s):  
S. Kantawanichkul ◽  
P. Neamkam ◽  
R.B.E. Shutes

Pig farm wastewater creates various problems in many areas throughout Thailand. Constructed wetland systems are an appropriate, low cost treatment option for tropical countries such as Thailand. In this study, a combined system (a vertical flow bed planted with Cyperus flabelliformis over a horizontal flow sand bed without plants) was used to treat settled pig farm wastewater . This system is suitable for using in farms where land is limited. The average COD and nitrogen loading rate of the vegetated vertical flow bed were 105 g/m2.d and 11 g/m2.d respectively. The wastewater was fed intermittently at intervals of 4 hours with a hydraulic loading rate of 3.7 cm/d. The recirculation of the effluent increased total nitrogen (TN) removal efficiency from 71% to 85%. The chemical oxygen demand (COD) and total Kjeldahl nitrogen (TKN) removal efficiencies were 95% and 98%. Nitrification was significant in vertical flow Cyperus bed, and the concentration of nitrate increased by a factor of 140. The horizontal flow sand bed enhanced COD removal and nitrate reduction was 60%. Plant uptake of nitrogen was 1.1 g N/m2.d or dry biomass production was 2.8 kg/m2 over 100 days.


Author(s):  
Rajani Ghaju Shrestha ◽  
Daisuke Inoue ◽  
Michihiko Ike

Abstract A constructed wetland (CW) is a low-cost, eco-friendly, easy-to-maintain, and widely applicable technology for treating various pollutants in the waste landfill leachate. This study determined the effects of the selection and compiling strategy of substrates used in CWs on the treatment performance of a synthetic leachate containing bisphenol A (BPA) as a representative recalcitrant pollutant. We operated five types of lab-scale vertical-flow CWs using only gravel (CW1), a sandwich of gravel with activated carbon (CW2) or brick crumbs (CW3), and two-stage hybrid CWs using gravel in one column and activated carbon (CW4) or brick crumbs (CW5) in another to treat synthetic leachate containing BPA in a 7-d sequential batch mode for 5 weeks. CWs using activated carbon (CW2 and CW4) effectively removed ammonium nitrogen (NH4-N) (99–100%), chemical oxygen demand (COD) (93–100%), and BPA (100%), indicating that the high adsorption capacity of activated carbon was the main mechanism involved in their removal. CW5 also exhibited higher pollutant removal efficiencies (NH4-N: 94–99%, COD: 89–98%, BPA: 89–100%) than single-column CWs (CW1 and CW3) (NH4-N: 76–100%, COD: 84–100%, BPA: 51–100%). This indicates the importance of the compiling strategy along with the selection of an appropriate substrate to improve the pollutant removal capability of CWs.


Processes ◽  
2020 ◽  
Vol 8 (5) ◽  
pp. 601 ◽  
Author(s):  
Tawfiq J. H. Banch ◽  
Marlia M. Hanafiah ◽  
Salem S. Abu Amr ◽  
Abbas F. M. Alkarkhi ◽  
Mohammed Hasan

Sanitary landfilling is the most common method of removing urban solid waste in developing countries. Landfills contain high levels of organic materials, ammonia, and heavy metals, thereby producing leachate which causes a possible future pollution of ground and surface water. Recently, agricultural waste was considered a co-substratum to promote the biodegradation of organics in industrial wastewater. The use of low-cost and natural materials for wastewater treatment is now being considered by many researchers. In this study, palm oil mill effluent (POME) was used for treating stabilized leachate from old landfill. A set of preliminary experiments using different POME/leachate ratios and aeration times was performed to identify the setting of experimental design and optimize the effect of employing POME on four responses: chemical oxygen demand (COD), total suspended solids (TSS), color, and ammoniacal nitrogen (NH3-N). The treatment efficiency was evaluated based on the removal of four selected (responses) parameters. The optimum removal efficiency for COD, TSS, color, and NH3-N was 87.15%, 65.54%, 52.78%, and 91.75%, respectively, using a POME/leachate mixing ratio of 188.32 mL/811.68 mL and 21 days of aeration time. The results demonstrate that POME-based agricultural waste can be effectively employed for organic removal from leachate.


Sign in / Sign up

Export Citation Format

Share Document