scholarly journals Simultaneous Quantification of Mixed-Acid Triacylglycerol Positional Isomers and Enantiomers in Palm Oil and Lard by Chiral High-Performance Liquid Chromatography Coupled with Mass Spectrometry

Symmetry ◽  
2020 ◽  
Vol 12 (9) ◽  
pp. 1385
Author(s):  
Toshiharu Nagai ◽  
Tetsuaki Kinoshita ◽  
Erika Kasamatsu ◽  
Kazuaki Yoshinaga ◽  
Hoyo Mizobe ◽  
...  

Palm oil and lard are edible fats which are rich in palmitic (P) and oleic acids (O). In this study, triacylglycerol (TAG) positional isomers (symmetric and asymmetric isomers) and enantiomers (asymmetric isomers) in palm oil and lard were quantified simultaneously by using liquid chromatography/mass spectrometry. The CHIRALPAK IF-3 column used in our previous study recognized the difference of TAG isomers consisting of P and O in palm oil and lard, separated sn-OPP/sn-PPO/sn-POP and sn-OPO/sn-OOP/sn-POO into each isomer peak, and enabled the quantification of these TAG isomers with good recovery (95–120%). Although sn-POP and sn-OPO were the major TAGs in palm oil and lard, a comparison of the abundance ratios of TAG enantiomers such as sn-PPO/sn-OPP and sn-OOP/sn-POO revealed that there were slightly more TAG enantiomers with O at the sn-1 position and P at the sn-3 position in palm oil and P at the sn-1 position and O at the sn-3 position in lard. These results were consistent with previous reports for the positional distribution of fatty acids of palm oil and lard. This is the first study that has enabled all TAG isomers consisting of P and O in natural oils and fats to be individually quantified by mass spectrometry.

2011 ◽  
Vol 11 ◽  
pp. 20-26 ◽  
Author(s):  
Gaodao Liang ◽  
Ping Xie ◽  
Jun Chen ◽  
Ting Yu

Microcystins (MCs) are well known worldwide as hepatotoxins produced by cyanobacteria, but little is known about the physicochemical properties of these compounds. The dependence of the n-octanol/water distribution ratio (DOW) of MC-RR and -LR to pH was measured by high-performance liquid chromatography combined with mass spectrometry (LC-MS). There was a remarkable difference in such relationships between MC-RR and -LR. The log DOWof MC-LR decreased from 1.63 at pH 1.0 to -1.26 at pH 6.5, and stabilized between -1.04 and -1.56 at a pH of 6.5~12.0; log DOWof MC-RR varied between -1.24 and -0.67 at a pH of 1.00~4.00, and stabilized between -1.20 and -1.54 at a pH of 4.00~12.00. The difference of hydrophobicity in acidic condition between MC-RR and -LR is important, not only for the analytical method of both toxins, but perhaps also for understanding the difference of toxicity to animals between the two toxins.


2007 ◽  
Vol 177 (4S) ◽  
pp. 295-295
Author(s):  
Michael Mullerad ◽  
Haleem J. Issaq ◽  
Alexander Kravtsov ◽  
Timothy Waybright ◽  
Brian Luke ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document