scholarly journals AR-Based Navigation Using RGB-D Camera and Hybrid Map

2021 ◽  
Vol 13 (10) ◽  
pp. 5585
Author(s):  
Woranipit Chidsin ◽  
Yanlei Gu ◽  
Igor Goncharenko

Current pedestrian navigation applications have been developed for the smartphone platform and guide users on a 2D top view map. The Augmented Reality (AR)-based navigation from the first-person view could provide a new experience for pedestrians compared to the current navigation. This research proposes a marker free system for AR-based indoor navigation. The proposed system adopts the RGB-D camera to observe the surrounding environment and builds a point cloud map using Simultaneous Localization and Mapping (SLAM) technology. After that, a hybrid map is developed by integrating the point cloud map and a floor map. Finally, positioning and navigation are performed on the proposed hybrid map. In order to visualize the augmented navigation information on the real scene seamlessly, this research proposes an orientation error correction method to improve the correctness of navigation. The experimental results indicated that the proposed system could provide first-person view navigation with satisfactory performance. In addition, compared to the baseline without any error correction, the navigation system with the orientation error correction method achieved significantly better performance. The proposed system is developed for the smart glasses and can be used as a touring tool.

2021 ◽  
Vol 263 ◽  
pp. 105817
Author(s):  
Jie Yang ◽  
Qingquan Liu ◽  
Gaoying Chen ◽  
Xuan Deng ◽  
Li Zhang

2018 ◽  
Vol 11 (9) ◽  
pp. 5167-5180 ◽  
Author(s):  
Kaisa Lakkala ◽  
Antti Arola ◽  
Julian Gröbner ◽  
Sergio Fabian León-Luis ◽  
Alberto Redondas ◽  
...  

Abstract. Non-ideal angular response of a spectroradiometer is a well-known error source of spectral UV measurements and for that reason instrument specific cosine error correction is applied. In this paper, the performance of the cosine error correction method of Brewer spectral UV measurements in use at the Finnish Meteorological Institute (FMI) is studied. Ideally, the correction depends on the actual sky radiation distribution, which can change even during one spectral scan due to rapid changes in cloudiness. The FMI method has been developed to take into account the changes in the ratio of direct to diffuse sky radiation and it derives a correction coefficient for each measured wavelength. Measurements of five Brewers were corrected for the cosine error and the results were compared to the reference travelling spectroradiometer (QASUME). Measurements were performed during the RBCC-E (Regional Brewer Calibration Center – Europe) X Campaign held at El Arenosillo, Huelva (37∘ N, 7∘ W), Spain, in 2015. In addition, results of site audits of FMI's Brewers in Sodankylä (67∘ N, 27∘ E) and Jokioinen (61∘ N, 24∘ E) during 2002–2014 were studied. The results show that the spectral cosine error correction varied between 4 and 14 %. After that the correction was applied to Brewer UV spectra the relative differences between the QASUME and the Brewer diminished even by 10 %. The study confirms that the method, originally developed for measurements at high latitudes, can be used at mid-latitudes as well. The method is applicable to other Brewers as far as the required input parameters, i.e. total ozone, aerosol information, albedo, instrument specific angular response and slit function are available.


Engineering ◽  
2012 ◽  
Vol 04 (11) ◽  
pp. 768-773 ◽  
Author(s):  
Saleh Al-Omar ◽  
Atef Obeidat

2014 ◽  
Vol 11 (3) ◽  
pp. 70-79 ◽  
Author(s):  
Li Ning ◽  
Lin Kanfeng ◽  
Lin Wenliang ◽  
Deng Zhongliang

Sign in / Sign up

Export Citation Format

Share Document