scholarly journals Comparative Analysis of Two Urban Microclimates: Energy Consumption and Greenhouse Gas Emissions

2019 ◽  
Vol 11 (7) ◽  
pp. 2045 ◽  
Author(s):  
Néstor Santillán-Soto ◽  
O. García-Cueto ◽  
Alejandro Lambert-Arista ◽  
Sara Ojeda-Benítez ◽  
Samantha Cruz-Sotelo

This paper presents a hypothetical and comparative performance of a 5 ton air conditioner (AC) operating in two zones in different urban microclimates for 25 days. One site represents a type of homogeneous planned urbanism and the other is a traditional heterogeneous zone. Air temperature data was collected and then processed using a linear regression model included in the operating manual of the AC in order to obtain their energy consumption. Results indicate that for an area with 500 homes, a traditional urban complex requires 12,350 kWh of electrical energy more than a planned zone (1.89%). This extra energy amounts up to $1180 and adds 9191 kg of CO2 to the atmosphere. The increased energy consumption has implications that increase the cost and environmental aspects of two urban microclimates, so that urbanization without planning is less friendly to the environment. In this sense, this study highlights the effects of urban microclimates on domestic electricity consumption from air conditioning. In addition, for a city with an arid desert climate, the variation in electricity consumption is associated with changes in the urban mosaic. The results found represent scientific evidence that can be used as a reference to establish public policies that could be incorporated into the local construction regulations, oriented to reduce the energy consumption associated with the use of air conditioning equipment.

Foristek ◽  
2021 ◽  
Vol 11 (2) ◽  
Author(s):  
Duldes S. Lambey ◽  
Nurhani Amin ◽  
Yulius S. Pirade ◽  
Rudi Santoso

Audit of Electrical Energy at the Regional House of Representatives of the Tojo Una-Una District is a comprehensive method in examining energy use in a building to find the value of Energy Consumption Intensity (IKE) and Energy Saving Opportunities (PHE) that can be obtained to reduce energy waste so that the consumption of electrical energy is more effective and efficient. The audit of Electrical Energy is carried out according to SNI 03-6196-2000 concerning Energy audit procedures in buildings and the Regulation of the Minister of Energy and Mineral Resources of the Republic of Indonesia Number 13 of 2012 concerning Savings Electricity Consumption. The results of the evaluation of the Energy Consumption Intensity Calculation conducted at the Office of the Regional House of Representatives of Tojo Una-Una District known that there are 16 rooms with the criteria for the Energy Consumption Intensity (IKE) value, namely an office building with air conditioning has efficient enough 8 rooms, wasteful 3 rooms and based on office buildings without Air-conditioning is quite efficient in 3 rooms and wasteful in 2 rooms. The results of Energy Saving Opportunities (PHE) that have been identified by using air conditioning and energy-saving lamps, reducing hours of use without reducing the quality of service in the office can save electricity consumption of 2.339,5165 kWh/month or save electricity bill payments of IDR. 3.379.899,60/month.


2021 ◽  
Vol 288 ◽  
pp. 01066
Author(s):  
Ahmed Al–Okbi ◽  
Yuri Vankov ◽  
Hasanen Mohammad Hussain

The process of operating an air conditioning system by hybrid energy that uses solar energy for purpose of saving electrical energy with improving the performance from modern and environmentally friendly systems. With high demand for air-conditioning systems in summer in hot regions, especially in Iraq due to high temperatures, the issue of using renewable energies becomes more attractive due to the continuous interruption of electrical energy. Air conditioners in Iraq consume more than half of the average electricity production. Therefore, saving energy leads to ensuring the reliability of electricity and reduces the consumption of fuel and gases that pollute the environment and negatively affect on the ozone layer. In the current research, the atmosphere of the city Baghdad was used to collect the solar thermal energy through a vacuum solar collector and combine it with a conventional air conditioner in order to reduce the electrical energy consumption on the compressor and increase the coefficient of performance. Several tests were conducted on the experimental device for comparing results with the conventional device and evaluating performance. The results showed that the performance with the vacuum solar collector became more efficient 8.97 instead of 4.27 than with the conventional system, and the energy consumption decreased by 52%.


2012 ◽  
Vol 16 (3) ◽  
pp. 131
Author(s):  
Didik Ariwibowo

Didik Ariwibowo, in this paper explain that energy audit activities conducted through several phases, namely: the initial audit, detailed audit, analysis of energy savings opportunities, and the proposed energy savings. Total energy consumed consists of electrical energy, fuel, and materials in this case is water. Electrical energy consumption data obtained from payment of electricity accounts for a year while consumption of fuel and water obtained from the payment of material procurement. From the calculation data, IKE hotels accounted for 420.867 kWh/m2.tahun, while the IKE standards for the hotel is 300 kWh/m2.tahun. Thus, IKE hotel included categorized wasteful in energy usage. The largest energy consumption on electric energy consumption. Largest electric energy consumption is on the air conditioning (AC-air conditioning) that is equal to 71.3%, and lighting and electrical equipment at 27.28%, and hot water supply system by 4.44%. Electrical energy consumption in AC looks very big. Ministry of Energy and Mineral Resources of the statutes, the profile of energy use by air conditioning at the hotel by 48.5%. With these considerations in the AC target for audit detail as the next phase of activity. The results of a detailed audit analysis to find an air conditioning system energy savings opportunities in pumping systems. Recommendations on these savings is the integration of automation on the pumping system and fan coil units (FCU). The principle of energy conservation in the pumping system is by installing variable speed drives (VSD) pump drive motor to adjust speed according to load on the FCU. Load variations FCU provide input on the VSD pumps to match. Adaptation is predicted pump can save electricity consumption up to 65.7%. Keywords: energy audit, IKE, AC


2020 ◽  
Vol 5 (1) ◽  
pp. 14
Author(s):  
Ghodbane Mokhtar

Air conditioning is one of the indispensable conditions of well-being in human life, so the face of this research to provide this basic necessity in remote areas and in desert places far from power grids. To achieve this goal, solar air conditioning has been adopted, where the compressor was replaced by an ejector, a parabolic trough solar collector and a small pump; this means that the solar air conditioner does not need a huge amount of electrical energy to operate. This paper is studding the thermodynamic cycles of this air conditioner as a function of changing the climatic conditions of Bouzaréah region in Algeria under several practical conditions of heat exchangers (Condenser, Evaporator and Generator). This study will allow the determination of the optical and thermal efficiency of the solar collector used as a solar thermal generator, refrigeration subsystem performance (COPEje) and system thermal ratio of the air conditioner, where the cooling load is estimated at 18 kW.


2019 ◽  
Vol 17 (1) ◽  
pp. 88
Author(s):  
Herman Nawir ◽  
Kusmanurwira Kusmanurwira ◽  
Alif Firdaus

Abstract In the hotel business, the use of energy is very important, especially in the use of electricity, the portion of usage and allocation of funds for its provision is the largest. It can be seen that equipment such as lights, elevators, refrigerators, laundry, heaters, pumps, to the air conditioning system are some of the dominant tools in operations in the hospitality world. The results of the initial energy audit and detailed audit at the Grand Clarion Hotel Makassar showed that the Energy Consumption Intensity (IKE) is still far from the standard, which is 300 kWh / m2 a year. The building uses the largest amount of electricity in the Grand Clarion Hotel Makassar in Building A, which is in the Guest Room area of the air conditioning unit. The results of the initial energy audit of Energy Consumption Intensity (IKE) electricity were 336.84 kWh / m2 year. Whereas based on the results of a detailed energy audit the electricity consumption intensity (IKE) of electricity is 395.51 kWh / m2 a year. Energy Saving Opportunities (PHE) in this energy audit is to evaluate the AC power in each room and recommend the replacement of lamp types. From the results of the IKE calculation after the application of PHE, it is found that the value is still quite high so that efforts to save must still be done. 


2011 ◽  
Vol 19 (02) ◽  
pp. 131-140
Author(s):  
QUBO LI ◽  
DEMISS A. AMIBE ◽  
NORBERT MÜLLER

An air conditioning system using water as refrigerant (R718) that compresses water vapor with multistage stage variable speed axial compressor with intercooling between stages by water injection is considered. Four stage compression with flash intercooling resulted in 50% improvement of coefficient of performance (COP) at full load compared to conventional refrigerants like R134a. The energy efficiency of an air conditioning unit is specified by seasonal energy efficiency ratio (SEER). SEER is defined as the ratio of cooling output of an air conditioner measured and electrical energy consumption as per AHRI 210/240 during cooling season. The SEER is computed after determining the evaporator cooling capacity and the electrical energy demand of the compressor at each bin temperature using assumed compressor isentropic efficiency, mechanical efficiency and electrical efficiency and multiplying by the weight of each bin temperature to determine the total for the cooling season. As a result of multistage compression, best part load performance of water as a refrigerant and operation of compressor near design point at part load due to variable speed drive, 50%–60% improvement in SEER is obtained compared to the best available in the market using conventional refrigerants such as R134a with single stage compression.


Author(s):  
HARTONO BUDI SANTOSO ◽  
SAPTO PRAJOGO ◽  
SRI PARYANTO MURSID

ABSTRAKPenghematan pada konsumsi listrik rumah tangga akan memberikan dampak pada konsumsi listrik nasional. Penelitian menunjukkan pemantauan terhadap konsumsi listrik rumah tangga akan memberikan dampak pada penghematan konsumsi listrik hingga 30%. Beberapa penelitian terkait pengembangan pemantauan terhadap konsumsi listrik rumah tangga masih menunjukkan hasil yang kurang memuaskan. Pada penelitian ini akan dikembangkan sistem pemantauan energi khususnya untuk beban rumah tangga berbasis teknologi IoT, sehingga dapat dilakukan pemantauan menggunaan energi listrik rumah tangga menggunakan aplikasi android di perangkat komunikasi telepon seluler (ponsel). Hasil pengujian akurasi pengukuran, dilakukan dengan membandingkan data pengukuran dengan alat ukur lain, menunjukkan pembacaan arus memiliki rata-rata error sebesar 0% sementara pembacaan tegangan memiliki rata-rata error sebesar 0,06%.Kata kunci: IoT, power meter, power monitor, konsumsi energi ABSTRACTThe savings on household electricity consumption will have an impact on national electricity consumption. Research shows that monitoring of household electricity consumption will have an impact on saving electricity consumption up to 30%. Direct monitoring starts from using cable to wireless technology. Some studies realated to developments of energy consumption monitoring still show unsatisfactory results.In this research will be developed energy monitoring system especially for household load based on IoT technology, so that can be monitored the use of household electrical energy using android application in communication device, handphone. The result of measurement measurement accuracy is done by comparing measurement data with other measuring instrument, indicating current reading has an average error of 0% while the voltage reading has an average error of 0.06%.Keywords: IoT, power meter, power Monitor, energy consumption


2021 ◽  
Vol 289 ◽  
pp. 05002
Author(s):  
О.S. Kuznetsova ◽  
V.V. Khanaev

Due to the ever-increasing volume of energy consumption, the number of power plants capable of generating the necessary amount of electrical energy inevitably increases. The development and construction of new renewable energy sources and distribution generation facilities, the increase in electricity consumption and the growth of the tariff stimulates the search for effective technological solutions. Also in connection with the increasing popularity and improvement of technologies, there is a natural need to assess the prospects and potential opportunities of SES in the region as a whole, and for the Irkutsk region and the Republic of Buryatia, in particular.


2021 ◽  
Vol 289 ◽  
pp. 01014
Author(s):  
Ahmed Al–Okbi ◽  
Yuri Vankov ◽  
Hakim Kadhim

At the present time, operating hybrid air-conditioning systems that use solar energy to saving electrical energy while improving the performance has become necessary to protect the environment, reduce pollution and emissions caused by using fuels and gases. In Iraq, temperatures reach half the boiling point at summer, therefore the demand for air conditioning systems increases, air conditioning systems consume more than half of average electricity production which affects on reliability and stability of the electrical energy thus leads to a continuous power outage. So, the issue of using renewable energies becomes more attractive. Because of saving energy leads to ensuring the reliability of electricity and reduces the consumption of fuels and gases that pollute on the environment and negatively affect on the ozone layer. In the current research, the atmosphere of Baghdad city was used to collect solar thermal energy and convert it into thermal energy through an evacuated solar collector by water and combine it with a conventional air conditioner in the part that follows the compressor in order to reduce the electrical energy consumption on the compressor and increase coefficient of performance. Several tests were conducted on the proposed system to compare results with the conventional system and evaluate performance. The results showed that the coefficient of performance with the hybrid system became 8.97 more efficient instead of 4.27 compared to the conventional system, and the energy consumption decreased by 52%.


Sign in / Sign up

Export Citation Format

Share Document