scholarly journals An On-Line Flow-Injection Sorbent Extraction System Coupled with Flame Atomic Absorption Spectrometry for Thallium Determination Using a PTFE Turning-Packed Column

Separations ◽  
2019 ◽  
Vol 6 (2) ◽  
pp. 22
Author(s):  
Viktoria Kazantzi ◽  
Aristidis Anthemidis

A novel time-based flow-injection–solid-phase extraction system (FI–SPE) coupled with flame atomic absorption spectrometry (FAAS) for automatic on-line preconcentration and determination of thallium was developed. The efficiency of poly-tetrafluoroethylene (PTFE) turnings packed into a column as sorbent material was investigated for thallium extraction. Total thallium was determined by oxidizing thallium(I) to thallium(III), adding bromine in acidic solution. The formed [TlBr4]− anionic bromo complex was retained onto the PTFE turnings by on-line mixing with sodium diethyl dithiocarbamate (DDTC). The preconcentrated Tl(III)-DDTC complex was then effectively eluted with methyl isobutyl ketone (MIBK) and introduced into the flame atomizer for measurement and quantification. The column proved to be effective, stable, and reproducible, with a long lifetime. The enrichment factor was 105 for 60 s preconcentration time, and the sampling frequency 40 h−1. The detection limit was 1.93 μg L−1, and the relative standard deviation (RSD) was 3.2% at 50.0 μg L−1 concentration. The accuracy of the proposed method was estimated by analyzing certified reference materials and environmental and biological samples.

2002 ◽  
Vol 85 (6) ◽  
pp. 1410-1414 ◽  
Author(s):  
Ricardo Fernández Orsi ◽  
Rodolfo G Wuilloud ◽  
Jorgelina C A de Wuilloud ◽  
Roberto A Olsina ◽  
Luis D Martinez

Abstract An on-line cadmium preconcentration and determination system implemented with flame atomic absorption spectrometry (FAAS) associated with flow injection was studied. Cadmium was retained as Cd-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol Cd-(5-Br-PADAP) complex, pH 9.3. The Cd complex was removed from the knotted reactor (KR) with ethanol. A total enhancement factor of 140 was obtained with respect to FAAS (40 for KR and 3.5 due to the use of ethanol) with preconcentration time of 120 s. The detection limit value for preconcentration of 1 g sample was 0.5 ng/g. The repeatability for 10 replicate determinations at 5.0 ng/g Cd level was 3.5% relative standard deviation, calculated from peak heights obtained. The calibration graph using the preconcentration system for Cd was linear with a correlation coefficient of 0.9990 at levels near the detection limits to at least 2000 ng/g. The method was successfully applied to determination of total Cd in honey samples.


2003 ◽  
Vol 86 (4) ◽  
pp. 839-845 ◽  
Author(s):  
Peng Liu ◽  
Qiaosheng Pu ◽  
Qiaoyu Sun ◽  
Zhixing Su

Abstract A simple and highly selective method was developed for the routine determination of trace or ultratrace amounts of gold and palladium in geological and metallurgical samples. The method uses flow injection on-line preconcentration and separation with determination by flame atomic absorption spectrometry. Au and Pd in the sample are adsorbed on a 2-mercaptopyrimidine chemically modified silica gel (MPMSG) packed microcolumn in a 0.50M HCl medium and then eluted with 0.5 or 1.0% thiourea solution. The eluates are introduced into the flame atomic absorption spectrometer directly. With the use of a 0.85 mL microcolumn (about 0.14 g MPMSG packed), the present system tolerated concentrations of common base metal ions up to 25.0 mg/mL and concentrations of anions up to 100.0 mg/mL when Au(III) at 0.100 μg/mL and Pd(II) at 0.200 μg/mL were preconcentrated for 60 s with a sample flow rate of 5.0 mL/min. The limits of detection were 3.1 ng/mL for Au(III) and 6.1 ng/mL for Pd(II) with relative standard deviations of ≤2.5%. The analytical results obtained by the proposed method for geological and metallurgical samples were in good agreement with the certified values.