scholarly journals Evaluation of Remote Photoplethysmography Measurement Conditions toward Telemedicine Applications

Sensors ◽  
2021 ◽  
Vol 21 (24) ◽  
pp. 8357
Author(s):  
Akito Tohma ◽  
Maho Nishikawa ◽  
Takuya Hashimoto ◽  
Yoichi Yamazaki ◽  
Guanghao Sun

Camera-based remote photoplethysmography (rPPG) is a low-cost and casual non-contact heart rate measurement method suitable for telemedicine. Several factors affect the accuracy of measuring the heart rate and heart rate variability (HRV) using rPPG despite HRV being an important indicator for healthcare monitoring. This study aimed to investigate the appropriate setup for precise HRV measurements using rPPG while considering the effects of possible factors including illumination, direction of the light, frame rate of the camera, and body motion. In the lighting conditions experiment, the smallest mean absolute R–R interval (RRI) error was obtained when light greater than 500 lux was cast from the front (among the following conditions—illuminance: 100, 300, 500, and 700 lux; directions: front, top, and front and top). In addition, the RRI and HRV were measured with sufficient accuracy at frame rates above 30 fps. The accuracy of the HRV measurement was greatly reduced when the body motion was not constrained; thus, it is necessary to limit the body motion, especially the head motion, in an actual telemedicine situation. The results of this study can act as guidelines for setting up the shooting environment and camera settings for rPPG use in telemedicine.

2016 ◽  
Vol 23 (4) ◽  
pp. 579-592 ◽  
Author(s):  
Jaromir Przybyło ◽  
Eliasz Kańtoch ◽  
Mirosław Jabłoński ◽  
Piotr Augustyniak

Abstract Videoplethysmography is currently recognized as a promising noninvasive heart rate measurement method advantageous for ubiquitous monitoring of humans in natural living conditions. Although the method is considered for application in several areas including telemedicine, sports and assisted living, its dependence on lighting conditions and camera performance is still not investigated enough. In this paper we report on research of various image acquisition aspects including the lighting spectrum, frame rate and compression. In the experimental part, we recorded five video sequences in various lighting conditions (fluorescent artificial light, dim daylight, infrared light, incandescent light bulb) using a programmable frame rate camera and a pulse oximeter as the reference. For a video sequence-based heart rate measurement we implemented a pulse detection algorithm based on the power spectral density, estimated using Welch’s technique. The results showed that lighting conditions and selected video camera settings including compression and the sampling frequency influence the heart rate detection accuracy. The average heart rate error also varies from 0.35 beats per minute (bpm) for fluorescent light to 6.6 bpm for dim daylight.


1994 ◽  
Vol 6 (2) ◽  
pp. 99-116 ◽  
Author(s):  
M. W. Oram ◽  
D. I. Perrett

Cells have been found in the superior temporal polysensory area (STPa) of the macaque temporal cortex that are selectively responsive to the sight of particular whole body movements (e.g., walking) under normal lighting. These cells typically discriminate the direction of walking and the view of the body (e.g., left profile walking left). We investigated the extent to which these cells are responsive under “biological motion” conditions where the form of the body is defined only by the movement of light patches attached to the points of limb articulation. One-third of the cells (25/72) selective for the form and motion of walking bodies showed sensitivity to the moving light displays. Seven of these cells showed only partial sensitivity to form from motion, in so far as the cells responded more to moving light displays than to moving controls but failed to discriminate body view. These seven cells exhibited directional selectivity. Eighteen cells showed statistical discrimination for both direction of movement and body view under biological motion conditions. Most of these cells showed reduced responses to the impoverished moving light stimuli compared to full light conditions. The 18 cells were thus sensitive to detailed form information (body view) from the pattern of articulating motion. Cellular processing of the global pattern of articulation was indicated by the observations that none of these cells were found sensitive to movement of individual limbs and that jumbling the pattern of moving limbs reduced response magnitude. A further 10 cells were tested for sensitivity to moving light displays of whole body actions other than walking. Of these cells 5/10 showed selectivity for form displayed by biological motion stimuli that paralleled the selectivity under normal lighting conditions. The cell responses thus provide direct evidence for neural mechanisms computing form from nonrigid motion. The selectivity of the cells was for body view, specific direction, and specific type of body motion presented by moving light displays and is not predicted by many current computational approaches to the extraction of form from motion.


2019 ◽  
Vol 15 (5) ◽  
pp. 155014771984712 ◽  
Author(s):  
Leonardo Juan Ramírez López ◽  
Arturo Rodriguez Garcia ◽  
Gabriel Puerta Aponte

The implementation of the Internet of things in healthcare is a promising challenge to achieve coverage for a bigger number of users in different places at lower costs. Internet of things might mean better technology regarding response time and proper control of medical parameters. This study introduces an Internet-of-things system for healthcare with possibilities to control medical variables according to recent breakthroughs in sensors and data processing. The goal of the system is to optimize the development of applications to obtain variables in real time and with less energy consumption. The proposed model is validated on the measurement and monitoring of oxygen saturation, heart rate, and body temperature in patients with respiratory disorders. This was achieved by the optimization of data acquisition, integrated into a secure architecture using Message Queuing Telemetry Transport protocol. A cloud architecture with interconnection to low-cost and open-source devices was implemented, which interconnect to the sensors and actuators’ network. The experimental results were statistically treated against the device pattern data, through hypothesis tests for mean differences to probe the accuracy of the model. Finally, the proposed model demonstrates an efficient performance in several clinical parameters, such as oxygen saturation and heart rate per minute.


Vibration ◽  
2018 ◽  
Vol 1 (2) ◽  
pp. 250-268 ◽  
Author(s):  
Katrien Van Nimmen ◽  
Guoping Zhao ◽  
André Seyfarth ◽  
Peter Van den Broeck

This paper proposes a methodology to reconstruct the vertical GRFs from the registered body motion that is reasonably robust against measurement noise. The vertical GRFs are reconstructed from the experimentally identified time-variant pacing rate and a generalised single-step load model available in the literature. The proposed methodology only requires accurately capturing the body motion within the frequency range 1–10 Hz and does not rely on the exact magnitude of the registered signal. The methodology can therefore also be applied when low-cost sensors are used and to minimize the impact of soft-tissue artefacts. In addition, the proposed procedure can be applied regardless of the position of the sensor on the human body, as long as the recorded body motion allows for identifying the time of a nominally identical event in successive walking cycles. The methodology is illustrated by a numerical example and applied to an experimental dataset where the ground reaction forces and the body motion were registered simultaneously. The results show that the proposed methodology allows for arriving at a good estimate of the vertical ground reaction forces. When the impact of soft-tissue artefacts is low, a comparable estimate can be obtained using Newton’s second law of motion.


Author(s):  
ANGELO MARIA SABATINI

The availability of inexpensive, miniaturized sensors and the development of efficient and accurate filtering algorithms are important elements in order that pedestrian navigation system (PNS) will become an enabling technology for monitoring unconstrained daily living activities of human subjects. In this paper, we develop and test a computational method that estimates the path traveled by a walker from in-shoe mounted tri-axis inertial and magnetic sensors. The interest for inertial and magnetic sensors stems from their low cost, suitable form factors, small power consumption, which may give rise to self-contained, portable PNS whose hindrance to walking is limited. An important element in our approach is represented by an extended Kalman filter (EKF), whose aim is to estimate the body part orientation and to perform the in-line calibration of the tri-axis magnetometer. Two validation tests are applied to either acceleration or magnetic vector measurements, in order to adapt the measurement noise covariance matrix against the effects of body motion and external magnetic fields on the sensed gravity and earth's magnetic fields involved in orientation determination. Additionally, some biomechanical facts about how humans normally move are exploited to enhance the positioning performance of the developed method.


2020 ◽  
Vol 8 (5) ◽  
pp. 5573-5575

In present days, Health issues are occurring more frequently. Because of climatic changes, industrialization and technical advancement which led to reduced physical activity. Saving lives requires monitoring the health conditions of people who have chronic diseases or heart related problems. Decrease in morbidity from disease and extend lives can be achieved by earlier detection of problems. When we reach a certain age we have to keep monitoring the three vital signs of the body to extend our lives. In this paper, we are designing a healthcare monitoring system which can either monitor or measure three vital signs i.e. heart rate, respiratory rate and body temperature of human body. The developed system uses wearable sensors to measure body temperature, heart rate and breathing rate. In order to minimize human involvement and respond at an appropriate time a health monitoring designed FGPA system will take the data from the sensors and analyze the date. It will give the health report, health status and alerts the concerned whenrequired.


Author(s):  
A. E. Chernikova ◽  
Yu. P. Potekhina

Introduction. An osteopathic examination determines the rate, the amplitude and the strength of the main rhythms (cardiac, respiratory and cranial). However, there are relatively few studies in the available literature dedicated to the influence of osteopathic correction (OC) on the characteristics of these rhythms.Goal of research — to study the influence of OC on the rate characteristics of various rhythms of the human body.Materials and methods. 88 adult osteopathic patients aged from 18 to 81 years were examined, among them 30 men and 58 women. All patients received general osteopathic examination. The rate of the cranial rhythm (RCR), respiratory rate (RR) heart rate (HR), the mobility of the nervous processes (MNP) and the connective tissue mobility (CTM) were assessed before and after the OC session.Results. Since age varied greatly in the examined group, a correlation analysis of age-related changes of the assessed rhythms was carried out. Only the CTM correlated with age (r=–0,28; p<0,05) in a statistically significant way. The rank dispersion analysis of Kruskal–Wallis also showed statistically significant difference in this indicator in different age groups (p=0,043). With the increase of years, the CTM decreases gradually. After the OC, the CTM, increased in a statistically significant way (p<0,0001). The RCR varied from 5 to 12 cycles/min in the examined group, which corresponded to the norm. After the OC, the RCR has increased in a statistically significant way (p<0,0001), the MNP has also increased (p<0,0001). The initial heart rate in the subjects varied from 56 to 94 beats/min, and in 15 % it exceeded the norm. After the OC the heart rate corresponded to the norm in all patients. The heart rate and the respiratory rate significantly decreased after the OC (р<0,0001).Conclusion. The described biorhythm changes after the OC session may be indicative of the improvement of the nervous regulation, of the normalization of the autonomic balance, of the improvement of the biomechanical properties of body tissues and of the increase of their mobility. The assessed parameters can be measured quickly without any additional equipment and can be used in order to study the results of the OC.


Author(s):  
A.M. Satarkulova

The assessment and dynamic control over students’ status is a very important task. It allows timely detection of prenosological status prior to pathology and health maintenance in students. The objective of the paper is to assess the adaptive abilities of the body, to analyze changes in heart rate variability indicators in students with various types of autonomic regulation, to identify prenosological status and precursory pathological symptoms. Materials and Methods. The study enrolled 302 students from India, aged 21.54±1.43. Programming complex «Psychophysiologist» was used to register the main HRV parameters within 5 minutes. Health status was evaluated according to the index of functional changes and the scale of functional states. Results. N.I. Shlyk (2009) distinguished two groups of students with different types of autonomic regulation: type 1 (53 %) with moderate and type 2 (5 %) with marked characteristics of central regulation profile, type 3 (35 %) with moderate and type 4 (7 %) with marked characteristics of autonomous regulation profile. Main parameters of HRV and adaptation potential were defined for each student.All the parameters characterized functional and health status. Conclusions. It was shown that 82 % of trial subjects (type 1), 53 % (type 2), 94 % (type 3) and 95 % (type 4) demonstrated satisfactory adaptation and their physiological processes were at an optimal level. 18 % of students (type 1) demonstrated reduced adaptive abilities of the body. Moreover, they were under moderate stress. 47 % of subjects (type 2) were also under a significant stress, which was proven by excessively high SI, low SDNN and TP, and an increased index of functional changes. 5 % of students (type 4) revealed dysfunctional characteristics in the heart rhythm, peculiar to pathology. Keywords: foreign students, heart rate variability, types of autonomic regulation, adaptation potential, functional status. Оценка состояния студентов и динамический контроль за ним является важной задачей, поскольку позволяет своевременно выявлять у студентов донозологические состояния, предшествующие патологии, и способствовать сохранению здоровья. Цель. Оценка адаптивных возможностей организма, анализ изменений показателей вариабельности сердечного ритма у студентов с различными типами вегетативной регуляции, выявление донозологических состояний и ранних признаков патологии. Материалы и методы. В исследовании участвовало 302 студента в возрасте 21,54+1,43 года из Индии. Регистрировались основные параметры ВСР в течение 5 мин с использованием программно-аппаратного комплекса «Психофизиолог». Состояние и уровень здоровья оценивались по индексу функциональных изменений и шкале функциональных состояний. Результаты. По способу, предложенному Н.И. Шлык, выделены группы студентов с различными типами вегетативной регуляции: I (53 %) и II типы (5 %) – с умеренным и выраженным преобладанием центрального контура регуляции соответственно, III (35 %) и IV типы (7 %) – с умеренным и выраженным преобладанием автономного контура регуляции соответственно. У каждого из студентов определены основные параметры ВСР и адаптационного потенциала, характеризующие функциональное состояние и уровень здоровья. Выводы. Показано, что для 82 % обследуемых с I типом, 53 % со II типом, 94 % c III типом и 95 % с IV типом регуляции характерно состояние удовлетворительной адаптации, физиологические процессы сохраняются на оптимальном уровне. В группе студентов I типа у 18 % студентов адаптивные возможности организма снижены, выявлено состояние умеренного напряжения. У 47 % обследуемых II типа также зафиксировано состояние резко выраженного напряжения, индикатором которого является чрезмерно высокое значение SI, низкие величины SDNN и ТP, повышенное значение индекса функциональных изменений. В группе студентов с IV типом у 5 % учащихсяв регуляции ритма сердца выявлены дисфункциональные признаки, характерные для патологии. Ключевые слова: иностранные студенты, вариабельность сердечного ритма, типы вегетативной регуляции, адаптационный потенциал, функциональное состояние.


Author(s):  
Алексей Дмитриевич Акишин ◽  
Иван Павлович Семчук ◽  
Александр Петрович Николаев

Постоянно растущий интерес к разработке новых неинвазивных и безманжетных методов измерения параметров сердечной деятельности, использование которых давало бы возможность непрерывного и удаленного контроля сердечно-сосудистой системы, обуславливает актуальность данной работы. В многочисленных публикациях продолжаются обсуждения преимуществ и недостатков различных методов ранней диагностики сердечно-сосудистых заболеваний. Однако артефакты движения являются сильной помехой, мешающей точной оценке показателей функционирования сердечно-сосудистой системы. Одним из перспективных методов контроля является метод оценки физиологических параметров с использованием фотоплетизмографии. Данная статья посвящена разработке устройства для фотоплетизмографических исследований и алгоритмических методов обработки регистрируемых сигналов для обеспечения мониторинга сердечного ритма с заданной точностью. В работе используются технологии цифровой адаптивной фильтрации полученных сигналов для мониторинга сердечного ритма в условиях внешних механических и электрических помеховых воздействий, ухудшающих точностные характеристики системы, а также разработана архитектура системы и изготовлен макет устройства, который позволил провести измерения для определения оптимального алгоритма цифровой обработки сигналов. При использовании устройства применялись методы адаптивной фильтрации на основе фильтров Винера, фильтров на основе метода наименьших квадратов и Калмановской фильтрации. Разработанное устройство для фотоплетизмографических исследований обеспечило возможность мониторинга сердечного ритма с заданной точностью, контроля текущего состояния организма и может быть использовано в качестве средства диагностики заболеваний сердца The constantly growing interest in the development of new non-invasive and cuff-free methods for measuring the parameters of cardiac activity, the use of which would give the possibility of continuous and remote monitoring of the cardiovascular system, determines the relevance of this work. Numerous publications continue to discuss the advantages and disadvantages of various methods of early diagnosis of cardiovascular disease. However, motion artifacts are a strong hindrance to the accurate assessment of the performance of the cardiovascular system. One of the promising control methods is the method for assessing physiological parameters using photoplethysmography. This article is devoted to the development of a device for photoplethysmographic studies and algorithmic methods for processing recorded signals to ensure monitoring of the heart rate with a given accuracy. The work uses technologies of digital adaptive filtering of the received signals to monitor the heart rate in conditions of external mechanical and electrical interference, which worsen the accuracy characteristics of the system, as well as the architecture of the system and a prototype of the device, which made it possible to carry out measurements to determine the optimal algorithm for digital signal processing. When using the device, the methods of adaptive filtering based on Wiener filters, filters based on the least squares method and Kalman filtering were used. The developed device for photoplethysmographic studies provided the ability to monitor the heart rate with a given accuracy, control the current state of the body and can be used as a means of diagnosing heart diseases


Sign in / Sign up

Export Citation Format

Share Document