scholarly journals Performance Analysis of Non-Interferometry Based Surface Plasmon Resonance Microscopes

Sensors ◽  
2021 ◽  
Vol 21 (15) ◽  
pp. 5230
Author(s):  
Sorawit Tontarawongsa ◽  
Sarinporn Visitsattapongse ◽  
Suejit Pechprasarn

Surface plasmon microscopy has been of interest to the science and engineering community and has been utilized in broad aspects of applications and studies, including biochemical sensing and biomolecular binding kinetics. The benefits of surface plasmon microscopy include label-free detection, high sensitivity, and quantitative measurements. Here, a theoretical framework to analyze and compare several non-interferometric surface plasmon microscopes is proposed. The scope of the study is to (1) identify the strengths and weaknesses in each surface plasmon microscopes reported in the literature; (2) quantify their performance in terms of spatial imaging resolution, imaging contrast, sensitivity, and measurement accuracy for quantitative and non-quantitative imaging modes of the microscopes. Six types of non-interferometric microscopes were included in this study: annulus aperture scanning, half annulus aperture scanning, single-point scanning, double-point scanning, single-point scanning, at 45 degrees azimuthal angle, and double-point scanning at 45 degrees azimuthal angle. For non-quantitative imaging, there is a substantial tradeoff between the image contrast and the spatial resolution. For the quantitative imaging, the half annulus aperture provided the highest sensitivity of 127.058 rad/μm2 RIU−1, followed by the full annulus aperture of 126.318 rad/μm2 RIU−1. There is a clear tradeoff between spatial resolution and sensitivity. The annulus aperture and half annulus aperture had an optimal resolution, sensitivity, and crosstalk compared to the other non-interferometric surface plasmon resonance microscopes. The resolution depends strongly on the propagation length of the surface plasmons rather than the numerical aperture of the objective lens. For imaging and sensing purposes, the recommended microfluidic channel size and protein stamping size for surface plasmon resonance experiments is at least 25 μm for accurate plasmonic measurements.

Biosensors ◽  
2018 ◽  
Vol 8 (4) ◽  
pp. 102 ◽  
Author(s):  
Richard Schasfoort ◽  
Fikri Abali ◽  
Ivan Stojanovic ◽  
Gestur Vidarsson ◽  
Leon Terstappen

SPR cytometry entails the measurement of parameters from intact cells using the surface plasmon resonance (SPR) phenomenon. Specific real-time and label-free binding of living cells to sensor surfaces has been made possible through the availability of SPR imaging (SPRi) instruments and researchers have started to explore its potential in the last decade. Here we will discuss the mechanisms of detection and additionally describe the problems and issues of mammalian cells in SPR biosensing, both from our own experience and with information from the literature. Finally, we build on the knowledge and applications that has already materialized in this field to give a forecast of some exciting applications for SPRi cytometry.


Author(s):  
Manuel Fuentes ◽  
Sanjeeva Svrivastava ◽  
Nirosahan Ramachandran ◽  
Eugenie Hainsworth ◽  
Josh LaBaer

2010 ◽  
Vol 82 (24) ◽  
pp. 10110-10115 ◽  
Author(s):  
Hana Šípová ◽  
Shile Zhang ◽  
Aimée M. Dudley ◽  
David Galas ◽  
Kai Wang ◽  
...  

Author(s):  
Masixole Y. Lugongolo ◽  
Sello Manoto ◽  
Charles Maphanga ◽  
Saturnin Ombinda-Lemboumba ◽  
Lebogang Thobakgale ◽  
...  

2019 ◽  
Vol 12 (4) ◽  
pp. 1007-1016 ◽  
Author(s):  
Mingfei Pan ◽  
Jingying Yang ◽  
Shijie Li ◽  
Wenjun Wen ◽  
Junping Wang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document