scholarly journals Self-Powered Point-of-Care Device for Galvanic Cell-Based Sample Concentration Measurement

Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2665
Author(s):  
Albert Álvarez-Carulla ◽  
Yaiza Montes-Cebrián ◽  
Jordi Colomer-Farrarons ◽  
Pere Lluís Miribel-Català

A novel self-powered point-of-care low-power electronics approach for galvanic cell-based sample concentration measurement is presented. The electronic system harvests and senses at the same time from the single cell. The system implements a solution that is suitable in those scenarios where extreme low power is generated from the fuel cell. The proposed approach implements a capacitive-based method to perform a non-linear sweep voltammetry to the cell, but without the need to implement a potentiostat amplifier for that purpose. It provides a digital-user readable result without the need for external non-self-powered devices or instruments compared with other solutions. The system conception was validated for a particular case. The scenario consisted of the measurement of a NaCl solution as the electrolyte, which was related to the conductivity of the sample. The electronic reader continuously measured the current with a transfer function gain of 1.012 V mA−1. The overall system exhibited a maximum coefficient of variation of 6.1%, which was an improvement compared with the state-of-the-art. The proof of concept of this electronics system was validated with a maximum power consumption of 5.8 μW using commercial-off-the-self parts.

Sensors ◽  
2019 ◽  
Vol 19 (17) ◽  
pp. 3715 ◽  
Author(s):  
Yaiza Montes-Cebrián ◽  
Albert Álvarez-Carulla ◽  
Jordi Colomer-Farrarons ◽  
Manel Puig-Vidal ◽  
Pere Ll. Miribel-Català

In this work, we present a self-powered electronic reader (e-reader) for point-of-care diagnostics based on the use of a fuel cell (FC) which works as a power source and as a sensor. The self-powered e-reader extracts the energy from the FC to supply the electronic components concomitantly, while performing the detection of the fuel concentration. The designed electronics rely on straightforward standards for low power consumption, resulting in a robust and low power device without needing an external power source. Besides, the custom electronic instrumentation platform can process and display fuel concentration without requiring any type of laboratory equipment. In this study, we present the electronics system in detail and describe all modules that make up the system. Furthermore, we validate the device’s operation with different emulated FCs and sensors presented in the literature. The e-reader can be adjusted to numerous current ranges up to 3 mA, with a 13 nA resolution and an uncertainty of 1.8%. Besides, it only consumes 900 µW in the low power mode of operation, and it can operate with a minimum voltage of 330 mV. This concept can be extended to a wide range of fields, from biomedical to environmental applications.


2019 ◽  
Vol 2019 ◽  
pp. 1-10 ◽  
Author(s):  
Daniel Ayala-Ruiz ◽  
Alejandro Castillo Atoche ◽  
Erica Ruiz-Ibarra ◽  
Edith Osorio de la Rosa ◽  
Javier Vázquez Castillo

Long power wide area networks (LPWAN) systems play an important role in monitoring environmental conditions for smart cities applications. With the development of Internet of Things (IoT), wireless sensor networks (WSN), and energy harvesting devices, ultra-low power sensor nodes (SNs) are able to collect and monitor the information for environmental protection, urban planning, and risk prevention. This paper presents a WSN of self-powered IoT SNs energetically autonomous using Plant Microbial Fuel Cells (PMFCs). An energy harvesting device has been adapted with the PMFC to enable a batteryless operation of the SN providing power supply to the sensor network. The low-power communication feature of the SN network is used to monitor the environmental data with a dynamic power management strategy successfully designed for the PMFC-based LoRa sensor node. Environmental data of ozone (O3) and carbon dioxide (CO2) are monitored in real time through a web application providing IoT cloud services with security and privacy protocols.


Micromachines ◽  
2021 ◽  
Vol 12 (3) ◽  
pp. 337
Author(s):  
Navneet Soin ◽  
Sam J. Fishlock ◽  
Colin Kelsey ◽  
Suzanne Smith

The use of rapid point-of-care (PoC) diagnostics in conjunction with physiological signal monitoring has seen tremendous progress in their availability and uptake, particularly in low- and middle-income countries (LMICs). However, to truly overcome infrastructural and resource constraints, there is an urgent need for self-powered devices which can enable on-demand and/or continuous monitoring of patients. The past decade has seen the rapid rise of triboelectric nanogenerators (TENGs) as the choice for high-efficiency energy harvesting for developing self-powered systems as well as for use as sensors. This review provides an overview of the current state of the art of such wearable sensors and end-to-end solutions for physiological and biomarker monitoring. We further discuss the current constraints and bottlenecks of these devices and systems and provide an outlook on the development of TENG-enabled PoC/monitoring devices that could eventually meet criteria formulated specifically for use in LMICs.


Sensors ◽  
2019 ◽  
Vol 19 (10) ◽  
pp. 2260 ◽  
Author(s):  
Francesca Criscuolo ◽  
Irene Taurino ◽  
Van Dam ◽  
Francky Catthoor ◽  
Marcel Zevenbergen ◽  
...  

Nanostructured materials have attracted considerable interest over the last few decades to enhance sensing capabilities thanks to their unique properties and large surface area. In particular, noble metal nanostructures offer several advantages including high stability, non-toxicity and excellent electrochemical behaviour. However, in recent years the great expansion of point-of-care (POC) and wearable systems and the attempt to perform measurements in tiny spaces have also risen the need of increasing sensors miniaturization. Fast constant potential electrodeposition techniques have been proven to be an efficient way to obtain conformal platinum and gold nanostructured layers on macro-electrodes. However, this technique is not effective on micro-electrodes. In this paper, we investigate an alternative one-step deposition technique of platinum nanoflowers on micro-electrodes by linear sweep voltammetry (LSV). The effective deposition of platinum nanoflowers with similar properties to the ones deposited on macro-electrodes is confirmed by morphological analysis and by the similar roughness factor (~200) and capacitance (~18 μ F/mm 2 ). The electrochemical behaviour of the nanostructured layer is then tested in an solid-contact (SC) L i + -selective micro-electrode and compared to the case of macro-electrodes. The sensor offers Nernstian calibration with same response time (~15 s) and a one-order of magnitude smaller limit of detection (LOD) ( 2.6 × 10 − 6 ) with respect to the macro-ion-selective sensors (ISE). Finally, sensor reversibility and stability in both wet and dry conditions is proven.


Nano Energy ◽  
2015 ◽  
Vol 14 ◽  
pp. 111-125 ◽  
Author(s):  
Seung Hyun Lee ◽  
Chang Kyu Jeong ◽  
Geon-Tae Hwang ◽  
Keon Jae Lee

2014 ◽  
Vol 67 (1) ◽  
Author(s):  
Wong How Hwan ◽  
Vinny Lam Siu Fan ◽  
Yusmeeraz Yusof

The purpose of this research is to design a low power integrated complementary metal oxide semiconductor (CMOS) detection circuit for charge-modulated field-effect transistor (CMFET) and it is used for the detection of deoxyribonucleic acid (DNA) hybridization. With the available CMOS technology, it allows the realization of complete systems which integrate the sensing units and transducing elements in the same device. Point-of-care (POC) testing device is a device that allows anyone to operate anywhere and obtain immediate results. One of the important features of POC device is low power consumption because it is normally battery-operated. The power consumption of the proposed integrated CMOS detection circuit requires only 14.87 mW. The detection circuit will amplify the electrical signal that comes from the CMFET to a specified level in order to improve the recording characteristics of the biosensor. Self-cascode topology was used in the drain follower circuit in order to reduce the channel length modulation effect. The proposed detection circuit was designed with 0.18µm Silterra CMOS fabrication process and simulated under Cadence Simulation Tool. 


2013 ◽  
Vol 9 (1) ◽  
pp. 103-117 ◽  
Author(s):  
Salah-Eddine Adami ◽  
Nicolas Degrenne ◽  
Walid Haboubi ◽  
Hakim Takhedmit ◽  
Denis Labrousse ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document