scholarly journals In Vivo Quantitative Vasculature Segmentation and Assessment for Photodynamic Therapy Process Monitoring Using Photoacoustic Microscopy

Sensors ◽  
2021 ◽  
Vol 21 (5) ◽  
pp. 1776
Author(s):  
Thi Thao Mai ◽  
Su Woong Yoo ◽  
Suhyun Park ◽  
Jin Young Kim ◽  
Kang-Ho Choi ◽  
...  

Vascular damage is one of the therapeutic mechanisms of photodynamic therapy (PDT). In particular, short-term PDT treatments can effectively destroy malignant lesions while minimizing damage to nonmalignant tissue. In this study, we investigate the feasibility of label-free quantitative photoacoustic microscopy (PAM) for monitoring the vasculature changes under the effect of PDT in mouse ear melanoma tumors. In particular, quantitative vasculature evaluation was conducted based on Hessian filter segmentation. Three-dimensional morphological PAM and depth-resolved images before and after PDT treatment were acquired. In addition, five quantitative vasculature parameters, including the PA signal, vessel diameter, vessel density, perfused vessel density, and vessel complexity, were analyzed to evaluate the influence of PDT on four different areas: Two melanoma tumors, and control and normal vessel areas. The quantitative and qualitative results successfully demonstrated the potential of the proposed PAM-based quantitative approach to evaluate the effectiveness of the PDT method.

Nanophotonics ◽  
2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Keegan Guidolin ◽  
Lili Ding ◽  
Juan Chen ◽  
Brian C. Wilson ◽  
Gang Zheng

Abstract Porphysomes (PS) are liposome-like nanoparticles comprising pyropheophorbide-conjugated phospholipids that have demonstrated potential as multimodal theranostic agents for applications that include phototherapies, targeted drug delivery and in vivo fluorescence, photoacoustic, magnetic resonance or positron emission imaging. Previous therapeutic applications focused primarily on photothermal therapy (PTT) and suggested that PSs require target-triggered activation for use as photodynamic therapy (PDT) sensitizers. Here, athymic nude mice bearing subcutaneous A549 human lung tumors were randomized into treatment and control groups: PS-PDT at various doses, PS-only and no treatment negative controls, as well as positive controls using the clinical photosensitizer Photofrin. Animals were followed for 30 days post-treatment. PS-PDT at all doses demonstrated a significant tumor ablative effect, with the greatest effect seen with 10 mg/kg PS at a drug-light interval of 24 h. By comparison, negative controls (PS-only, Photofrin-only, and no treatment) showed uncontrolled tumor growth. PDT with Photofrin at 5 mg/kg and PS at 10 mg/kg demonstrated similar tumor growth suppression and complete tumor response rates (15 vs. 25%, p = 0.52). Hence, porphysome nanoparticles are an effective PDT agent and have the additional advantages of multimodal diagnostic and therapeutic applications arising from their intrinsic structure. Porphysomes may also be the first single all-organic agent capable of concurrent PDT and PTT.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Javier Caviedes-Bucheli ◽  
Nestor Rios-Osorio ◽  
Diana Usme ◽  
Cristian Jimenez ◽  
Adriana Pinzon ◽  
...  

Abstract Background The purpose of this study was to evaluate the changes in canal volume after root canal preparation in vivo with 3 different single-file techniques (Reciproc-Blue®, WaveOne-Gold® and XP-EndoShaper®), with a new method using CBCT and 3D reconstruction. Methods In this prospective study, thirty human lower premolars from healthy patients were used, in which extraction was indicated for orthodontic reasons. All the teeth used were caries- and restoration-free with complete root development, without signs of periodontal disease or traumatic occlusion, and with only one straight canal (up to 25º curvature). Teeth were randomly divided into three different groups: Reciproc-Blue, WaveOne-Gold and XP-EndoShaper. CBCT scans before root canal preparation were used to create a 3D reconstruction with RHINOCEROS 5.0 software to assess the initial canal volume, and then compared with 3D reconstructions after canal preparation to measure the increase in canal volume. Student’s t test for paired data were used to determine statistically significant differences between the before and after canal volumes. Anova test was used to determine statistically significant differences in the percentage of canal volume increase between the groups and Tukey's post-hoc test were used to paired comparison. Results Reciproc-Blue showed the higher increase in canal volume, followed by WaveOne-Gold and XP-EndoShaper (p = 0.003). XP-EndoShaper did not show a statistically significant increase in canal volume after root canal preparation (p = 0.06). Conclusion With this model, Reciproc-Blue showed higher increase in root canal volume, followed by WaveOne-Gold, while XP-EndoShaper did not significantly increase root canal volume during preparation.


Author(s):  
Yinhao Pan ◽  
Ningbo Chen ◽  
Liangjian Liu ◽  
Chengbo Liu ◽  
Zhiqiang Xu ◽  
...  

AbstractPhotoacoustic microscopy is an in vivo imaging technology based on the photoacoustic effect. It is widely used in various biomedical studies because it can provide high-resolution images while being label-free, safe, and harmless to biological tissue. Polygon-scanning is an effective scanning method in photoacoustic microscopy that can realize fast imaging of biological tissue with a large field of view. However, in polygon-scanning, fluctuations of the rotating motor speed and the geometric error of the rotating mirror cause image distortions, which seriously affect the photoacoustic-microscopy imaging quality. To improve the image quality of photoacoustic microscopy using polygon-scanning, an image correction method is proposed based on accurate ultrasound positioning. In this method, the photoacoustic and ultrasound imaging data of the sample are simultaneously obtained, and the angle information of each mirror used in the polygon-scanning is extracted from the ultrasonic data to correct the photoacoustic images. Experimental results show that the proposed method can significantly reduce image distortions in photoacoustic microscopy, with the image dislocation offset decreasing from 24.774 to 10.365 μm.


2010 ◽  
Vol 35 (19) ◽  
pp. 3195 ◽  
Author(s):  
Chi Zhang ◽  
Konstantin Maslov ◽  
Lihong V. Wang

Author(s):  
Xiufeng Li ◽  
Victor T C Tsang ◽  
Lei Kang ◽  
Yan Zhang ◽  
Terence T W Wong

AbstractLaser diodes (LDs) have been considered as cost-effective and compact excitation sources to overcome the requirement of costly and bulky pulsed laser sources that are commonly used in photoacoustic microscopy (PAM). However, the spatial resolution and/or imaging speed of previously reported LD-based PAM systems have not been optimized simultaneously. In this paper, we developed a high-speed and high-resolution LD-based PAM system using a continuous wave LD, operating at a pulsed mode, with a repetition rate of 30 kHz, as an excitation source. A hybrid scanning mechanism that synchronizes a one-dimensional galvanometer mirror and a two-dimensional motorized stage is applied to achieve a fast imaging capability without signal averaging due to the high signal-to-noise ratio. By optimizing the optical system, a high lateral resolution of 4.8 μm has been achieved. In vivo microvasculature imaging of a mouse ear has been demonstrated to show the high performance of our LD-based PAM system.


Author(s):  
Karen Perta ◽  
Eileen Kalmar ◽  
Youkyung Bae

Purpose The aim of the study was to update our information regarding the salpingopharyngeus (SP) muscle using cadaveric and in vivo magnetic resonance imaging (MRI) data. Primary objectives were to (a) observe the presence/absence of the muscle and (b) quantify and describe its dimensions and course. Method SP specimens from 19 cadavers (10 women, nine men) were analyzed. Following head bisection, measurements of SP, including width of the cartilaginous attachment (CW) and width of the superior muscle base (SMW), were taken before and after removal of the overlying mucosa. In addition, SP was analyzed in 15 healthy subjects (eight men, seven women) using high-resolution three-dimensional MRI data. CW and SMW measures were replicated in the paraxial MRI view. Results The presence of the salpingopharyngeal fold and muscle was confirmed bilaterally in all cadaveric and living subjects. Following mucosa removal, mean cadaveric CW and SMW measurements were 5.6 and 3.8 mm, respectively. Mean in vivo CW and SMW were 6.1 and 3.7 mm, respectively. Results from the hierarchical regression analyses revealed that, in both cadaveric and living groups, SMW is dependent on the relationship between age and body weight, after controlling for sex. Conclusions The salpingopharyngeal fold and SP muscle are always present bilaterally and can be quantified at the superior origin using both cadaveric and in vivo three-dimensional MRI data. Though both the superior origin and inferior course of SP are highly variable, the size of the SP muscle is dependent on characteristics known to affect muscle fibers, such as the relationship between age and body weight. Given the consistent and quantifiable presence of the SP muscle, its potential role in velopharyngeal function for speech and swallowing is reconsidered. Supplemental Material https://doi.org/10.23641/asha.14347859


2006 ◽  
Vol 11 (3) ◽  
pp. 034032 ◽  
Author(s):  
Jung-Taek Oh ◽  
Meng-Lin Li ◽  
Hao F. Zhang ◽  
Konstantin Maslov ◽  
George Stoica ◽  
...  

2003 ◽  
Vol 96 (1) ◽  
pp. 127-136 ◽  
Author(s):  
Chiarella Sforza ◽  
Gian Piero Grassi ◽  
Michela Turci ◽  
Nicola Fragnito ◽  
Giuliano Pizzini ◽  
...  

To assess the influence of training on the maintenance of equilibrium on a tilting platform, 13 young healthy male athletes aged 19 to 33 years were randomly divided into experimental ( n = 7) and control ( n = 6) groups. Two experimental sessions were performed before and after a specific 4-wk. training by the experimental group. Subjects stood upright on a tilting platform. The athletes were asked to maintain the platform as horizontal as possible during a 30-sec. test. The three-dimensional movements of the platform versus the ground were recorded by using a computerized optoelectronic digitiser. The platform plane was calculated and its directrix computed. The area of oscillation and instantaneous angular velocity of the directrix at standardized height were calculated. In both groups the area of oscillation and the angular velocity were reduced in Session 2, but the reduction was significant only in the experimental group. Specific training can significantly improve skill at maintaining equilibrium in young healthy sport performers.


Sign in / Sign up

Export Citation Format

Share Document