scholarly journals A Portable Tunable Diode Laser Absorption Spectroscopy System for Dissolved CO2 Detection Using a High-Efficiency Headspace Equilibrator

Sensors ◽  
2021 ◽  
Vol 21 (5) ◽  
pp. 1723
Author(s):  
Zhihao Zhang ◽  
Meng Li ◽  
Jinjia Guo ◽  
Baolu Du ◽  
Ronger Zheng

Continuous observation of aquatic pCO2  at the ocean surface, with a sensitive response time and high spatiotemporal resolution, is essential for research into the carbon biogeochemical cycle. In this work, a portable tunable diode laser absorption spectroscopy (TDLAS) system for dissolved CO2 detection in surface seawater, coupled with a home-made headspace equilibrator, allowing real time underway measurements, is described. Both the optical detection part and sample extraction part were integrated together into a compact chamber. An empirical equation suitable for this system was acquired, which can convert the concentration from the gas-phase to the aqueous-phase. A monitoring precision of 0.5% was obtained with time-series measurement, and the detection limits of 2.3 ppmv and 0.1 ppmv were determined with 1 s and 128 s averaging time, respectively. Sampling device used in this work was ameliorated so that the response time of system reduced by about 50% compared to the traditional ‘shower head’ system. The fast response time reached the order of 41 s when the final concentration span was 3079 ppmv. For1902 ppmv, this figure was as short as 20 s. Finally, a field underway measurement campaign was carried out and the results were briefly analyzed. Our work proved the feasibility of the TDLAS system for dissolved CO2 rapid detection.

2021 ◽  
Vol 16 (2) ◽  
pp. 222-229
Author(s):  
Lin Feng ◽  
Jian Wang ◽  
Chao Ding

Tunable diode laser absorption spectroscopy (TDLAS) technology is adopted herein to detect fire gas produced in the early stage of the fire. Based on this technology, a fire warning detection system with multiple lasers and detectors is proposed. Multiple drivers input laser’s temperature and injected current data, making its output wavelength consistent with the measured gas’ absorption peak wavelengths in absorption spectroscopy. Multiple light beams are coupled to the same optical fiber. After the light beams pass through the long optical path absorption cell filled with fire gas, the beams are separated by a converter. The signals are demodulated by different detectors and further analyzed for fire warnings. After the fire warning system’s design, the system’s various hardware modules are designed, including the light source module, TDLAS controller, gas chamber module, photoelectric detector, and data collection. When the temperature remains unchanged, the output wavelength is linearly related to the injected current. When the injected current remains unchanged, the output wavelength is linearly related to the operating temperature. With a semiconductor laser’s injected current of 40 mA, the initial temperature of 38.6 °C, and the output wavelength of 1578.16 nm, the output wavelength increases continuously as the temperature increases. The harmonic signal amplitude after gas absorption is positively correlated with the measured gas concentration, indicating that the second harmonic signals can estimate the fire gas concentration.


2013 ◽  
Vol 38 (14) ◽  
pp. 2428 ◽  
Author(s):  
P. Adámek ◽  
J. Olejníček ◽  
M. Čada ◽  
Š. Kment ◽  
Z. Hubička

Sign in / Sign up

Export Citation Format

Share Document