scholarly journals The Validity of MotionSense HRV in Estimating Sedentary Behavior and Physical Activity under Free-Living and Simulated Activity Settings

Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1411
Author(s):  
Sunku Kwon ◽  
Neng Wan ◽  
Ryan D. Burns ◽  
Timothy A. Brusseau ◽  
Youngwon Kim ◽  
...  

MotionSense HRV is a wrist-worn accelerometery-based sensor that is paired with a smartphone and is thus capable of measuring the intensity, duration, and frequency of physical activity (PA). However, little information is available on the validity of the MotionSense HRV. Therefore, the purpose of this study was to assess the concurrent validity of the MotionSense HRV in estimating sedentary behavior (SED) and PA. A total of 20 healthy adults (age: 32.5 ± 15.1 years) wore the MotionSense HRV and ActiGraph GT9X accelerometer (GT9X) on their non-dominant wrist for seven consecutive days during free-living conditions. Raw acceleration data from the devices were summarized into average time (min/day) spent in SED and moderate-to-vigorous PA (MVPA). Additionally, using the Cosemed K5 indirect calorimetry system (K5) as a criterion measure, the validity of the MotionSense HRV was examined in simulated free-living conditions. Pearson correlations, mean absolute percent errors (MAPE), Bland–Altman (BA) plots, and equivalence tests were used to examine the validity of the MotionSense HRV against criterion measures. The correlations between the MotionSense HRV and GT9X were high and the MAPE were low for both the SED (r = 0.99, MAPE = 2.4%) and MVPA (r = 0.97, MAPE = 9.1%) estimates under free-living conditions. BA plots illustrated that there was no systematic bias between the MotionSense HRV and criterion measures. The estimates of SED and MVPA from the MotionSense HRV were significantly equivalent to those from the GT9X; the equivalence zones were set at 16.5% for SED and 29% for MVPA. The estimates of SED and PA from the MotionSense HRV were less comparable when compared with those from the K5. The MotionSense HRV yielded comparable estimates for SED and PA when compared with the GT9X accelerometer under free-living conditions. We confirmed the promising application of the MotionSense HRV for monitoring PA patterns for practical and research purposes.

Sensors ◽  
2019 ◽  
Vol 19 (24) ◽  
pp. 5344
Author(s):  
Wouter Bijnens ◽  
Jos Aarts ◽  
An Stevens ◽  
Darcy Ummels ◽  
Kenneth Meijer

Due to a lack of transparency in both algorithm and validation methodology, it is difficult for researchers and clinicians to select the appropriate tracker for their application. The aim of this work is to transparently present an adjustable physical activity classification algorithm that discriminates between dynamic, standing, and sedentary behavior. By means of easily adjustable parameters, the algorithm performance can be optimized for applications using different target populations and locations for tracker wear. Concerning an elderly target population with a tracker worn on the upper leg, the algorithm is optimized and validated under simulated free-living conditions. The fixed activity protocol (FAP) is performed by 20 participants; the simulated free-living protocol (SFP) involves another 20. Data segmentation window size and amount of physical activity threshold are optimized. The sensor orientation threshold does not vary. The validation of the algorithm is performed on 10 participants who perform the FAP and on 10 participants who perform the SFP. Percentage error (PE) and absolute percentage error (APE) are used to assess the algorithm performance. Standing and sedentary behavior are classified within acceptable limits (±10% error) both under fixed and simulated free-living conditions. Dynamic behavior is within acceptable limits under fixed conditions but has some limitations under simulated free-living conditions. We propose that this approach should be adopted by developers of activity trackers to facilitate the activity tracker selection process for researchers and clinicians. Furthermore, we are convinced that the adjustable algorithm potentially could contribute to the fast realization of new applications.


Author(s):  
Shohei Yano ◽  
Mohammad Javad Koohsari ◽  
Ai Shibata ◽  
Kaori Ishii ◽  
Suzanne Mavoa ◽  
...  

Various accelerometers have been used in research measuring physical activity (PA) and sedentary behavior (SB). This study compared two triaxial accelerometers—Active style Pro (ASP) and ActiGraph (AG)—in measuring PA and SB during work and nonwork days in free-living conditions. A total of 50 working participants simultaneously wore these two accelerometers on one work day and one nonwork day. The difference and agreement between the ASP and AG were analyzed using paired t-tests, Bland–Altman plots, and intraclass coefficients, respectively. Correction factors were provided by linear regression analysis. The agreement in intraclass coefficients was high among all PA intensities between ASP and AG. SB in the AG vertical axis was approximately 103 min greater than ASP. Regarding moderate-to-vigorous-intensity PA (MVPA), ASP had the greatest amount, followed by AG. There were significant differences in all variables among these devices across all day classifications, except for SB between ASP and AG vector magnitude. The correction factors decreased the differences of SB and MVPA. PA time differed significantly between ASP and AG. However, SB and MVPA differences between these two devices can be decreased using correction factors, which are useful methods for public health researchers.


2021 ◽  
Author(s):  
Kaja Kastelic ◽  
Marina Dobnik ◽  
Stefan Loefler ◽  
Christian Hofer ◽  
Nejc Šarabon

BACKGROUND Wrist worn consumer-grade activity trackers are popular devices, developed mainly for personal use, but with the potential to be used also for clinical and research purposes. OBJECTIVE The objective of this study was to explore the validity, reliability and sensitivity to change of movement behaviours metrics from three popular activity trackers (POLAR Vantage M, Garmin Vivosport and Garmin Vivoactive 4s) in controlled and free-living conditions when worn by older adults. METHODS Participants (n = 28; 74 ± 5 years) underwent a videotaped laboratory protocol while wearing all three activity trackers. On a separate occasion, participants wore one (randomly assigned) activity tracker and a research grade physical activity monitor ActiGraph wGT3X-BT simultaneously for six consecutive days for comparisons. RESULTS Both Garmin activity trackers showed excellent performance for step counts, with mean absolute percentage error (MAPE) below 20 % and intraclass correlation coefficient (ICC2,1) above 0.90 (P < .05), while Polar Vantage M substantially over counted steps (MAPE = 84 % and ICC2,1 = 0.37 for free-living conditions). MAPE for sleep time was within 10 % for all the trackers tested, while far beyond 20 % for all the physical activity and calories burned outputs. Both Garmin trackers showed fair agreement (ICC2,1 = 0.58–0.55) for measuring calories burned when compared with ActiGraph. CONCLUSIONS Garmin Vivoactive 4s showed overall best performance, especially for measuring steps and sleep time in healthy older adults. Minimal detectible change was consistently lower for an average day measures than for a single day measure, but still relatively high. The results provided in this study could be used to guide choice on activity trackers aiming for different purposes – individual use/care, longitudinal monitoring or in clinical trial setting.


2020 ◽  
Vol 3 (2) ◽  
pp. 100-109
Author(s):  
Christopher P. Connolly ◽  
Jordana Dahmen ◽  
Robert D. Catena ◽  
Nigel Campbell ◽  
Alexander H.K. Montoye

Purpose: We aimed to determine the step-count validity of commonly used physical activity monitors for pregnancy overground walking and during free-living conditions. Methods: Participants (n = 39, 12–38 weeks gestational age) completed six 100-step overground walking trials (three self-selected “normal pace”, three “brisk pace”) while wearing five physical activity monitors: Omron HJ-720 (OM), New Lifestyles 2000 (NL), Fitbit Flex (FF), ActiGraph Link (AG), and Modus StepWatch (SW). For each walking trial, monitor-recorded steps and criterion-measured steps were assessed. Participants also wore all activity monitors for an extended free-living period (72 hours), with the SW used as the criterion device. Mean absolute percent error (MAPE) was calculated for overground walking and free-living protocols and compared across monitors. Results: For overground walking, the OM, NL, and SW performed well (<5% MAPE) for normal and brisk pace walking trials, and also when trials were analyzed by actual speeds. The AG and FF had significantly greater MAPE for overground walking trials (11.9–14.7%). Trimester did affect device accuracy to some degree for the AG, FF, and SW, with error being lower in the third trimester compared to the second. For the free-living period, the OM, NL, AG, and FF significantly underestimated (>32% MAPE) actual steps taken per day as measured by the criterion SW (M [SD] = 9,350 [3,910]). MAPE for the OM was particularly high (45.3%). Conclusion: The OM, NL, and SW monitors are valid measures for overground step-counting during pregnancy walking. However, the OM and NL significantly underestimate steps by second and third trimester pregnant women in free-living conditions.


2004 ◽  
Vol 36 (Supplement) ◽  
pp. S329
Author(s):  
Jennifer L. Caputo ◽  
Richard S. Farley ◽  
Wayland Tseh

2013 ◽  
Vol 2 ◽  
Author(s):  
Marie Löf ◽  
Hanna Henriksson ◽  
Elisabet Forsum

AbstractActivity energy expenditure (AEE) during free-living conditions can be assessed using devices based on different principles. To make proper comparisons of different devices' capacities to assess AEE, they should be evaluated in the same population. Thus, in the present study we evaluated, in the same group of subjects, the ability of three devices to assess AEE in groups and individuals during free-living conditions. In twenty women, AEE was assessed using RT3 (three-axial accelerometry) (AEERT3), Actiheart (a combination of heart rate and accelerometry) (AEEActi) and IDEEA (a multi-accelerometer system) (AEEIDEEA). Reference AEE (AEEref) was assessed using the doubly labelled water method and indirect calorimetry. Average AEEActi was 5760 kJ per 24 h and not significantly different from AEEref (5020 kJ per 24 h). On average, AEERT3 and AEEIDEEA were 2010 and 1750 kJ per 24 h lower than AEEref, respectively (P < 0·001). The limits of agreement (± 2 sd) were 2940 (Actiheart), 1820 (RT3) and 2650 (IDEEA) kJ per 24 h. The variance for AEERT3 was lower than for AEEActi (P = 0·006). The RT3 classified 60 % of the women in the correct activity category while the corresponding value for IDEEA and Actiheart was 30 %. In conclusion, the Actiheart may be useful for groups and the RT3 for individuals while the IDEEA requires further development. The results are likely to be relevant for a large proportion of Western women of reproductive age and demonstrate that the procedure selected to assess physical activity can greatly influence the possibilities to uncover important aspects regarding interactions between physical activity, diet and health.


Author(s):  
NICOLE Y. J. M. LEENDERS ◽  
W. MICHAEL SHERMAN ◽  
H. N. NAGARAJA ◽  
C. LAWRENCE KIEN

2013 ◽  
Vol 31 (16) ◽  
pp. 1805-1814 ◽  
Author(s):  
Makoto Ayabe ◽  
Peter H. Brubaker ◽  
Yoshiyuki Sunami ◽  
Hideaki Kumahara ◽  
Yves Schutz ◽  
...  