scholarly journals Visual Measurement System for Wheel–Rail Lateral Position Evaluation

Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1297
Author(s):  
Viktor Skrickij ◽  
Eldar Šabanovič ◽  
Dachuan Shi ◽  
Stefano Ricci ◽  
Luca Rizzetto ◽  
...  

Railway infrastructure must meet safety requirements concerning its construction and operation. Track geometry monitoring is one of the most important activities in maintaining the steady technical conditions of rail infrastructure. Commonly, it is performed using complex measurement equipment installed on track-recording coaches. Existing low-cost inertial sensor-based measurement systems provide reliable measurements of track geometry in vertical directions. However, solutions are needed for track geometry parameter measurement in the lateral direction. In this research, the authors developed a visual measurement system for track gauge evaluation. It involves the detection of measurement points and the visual measurement of the distance between them. The accuracy of the visual measurement system was evaluated in the laboratory and showed promising results. The initial field test was performed in the Vilnius railway station yard, driving at low velocity on the straight track section. The results show that the image point selection method developed for selecting the wheel and rail points to measure distance is stable enough for TG measurement. Recommendations for the further improvement of the developed system are presented.

Author(s):  
Klaus Heinemann ◽  
Helmut Poppa

An electron detector with small detection area for use in the final image plane of a transmission electron microscope has been commercially offered by TEM manufacturers (1). However, little has been reported about the application of such a device. In this report, the construction principle and the operation of a novel microdensitometry device is described which combines precision image point selection with versatility, high sensitivity, ease of operation, and comparatively low cost.The electron microdensitometer system consists of a transparent phosphor screen onto which the electron image is projected, a small “channeltron” electron multiplier (supplied by Galileo/Bendix) underneath, and a closed-circuit TV system (Fig.l). The screen has an effective diameter of 45 mm and contains a 2 mm concentric hole which allows a small beam of electrons to pass unobstructed to the electron multiplier. The multiplier consists of a 3 mm O.D. tube in custom L-shaped configuration and is mounted such that its collector is located outside the screen area to minimize obstruction of the image viewed on the TV monitor.


ROBOT ◽  
2011 ◽  
Vol 33 (3) ◽  
pp. 299-302 ◽  
Author(s):  
Yi WANG ◽  
Changjie LIU ◽  
Xueyou YANG ◽  
Shenghua YE

Sensors ◽  
2021 ◽  
Vol 21 (7) ◽  
pp. 2480
Author(s):  
Isidoro Ruiz-García ◽  
Ismael Navarro-Marchal ◽  
Javier Ocaña-Wilhelmi ◽  
Alberto J. Palma ◽  
Pablo J. Gómez-López ◽  
...  

In skiing it is important to know how the skier accelerates and inclines the skis during the turn to avoid injuries and improve technique. The purpose of this pilot study with three participants was to develop and evaluate a compact, wireless, and low-cost system for detecting the inclination and acceleration of skis in the field based on inertial measurement units (IMU). To that end, a commercial IMU board was placed on each ski behind the skier boot. With the use of an attitude and heading reference system algorithm included in the sensor board, the orientation and attitude data of the skis were obtained (roll, pitch, and yaw) by IMU sensor data fusion. Results demonstrate that the proposed IMU-based system can provide reliable low-drifted data up to 11 min of continuous usage in the worst case. Inertial angle data from the IMU-based system were compared with the data collected by a video-based 3D-kinematic reference system to evaluate its operation in terms of data correlation and system performance. Correlation coefficients between 0.889 (roll) and 0.991 (yaw) were obtained. Mean biases from −1.13° (roll) to 0.44° (yaw) and 95% limits of agreements from 2.87° (yaw) to 6.27° (roll) were calculated for the 1-min trials. Although low mean biases were achieved, some limitations arose in the system precision for pitch and roll estimations that could be due to the low sampling rate allowed by the sensor data fusion algorithm and the initial zeroing of the gyroscope.


2012 ◽  
Vol 61 (5) ◽  
pp. 1231-1236 ◽  
Author(s):  
Bruno Ando ◽  
Salvatore Baglio ◽  
Angela Beninato

2013 ◽  
Vol 30 (10) ◽  
pp. 2352-2366 ◽  
Author(s):  
Dale A. Lawrence ◽  
Ben B. Balsley

Abstract The DataHawk small airborne measurement system provides in situ atmospheric measurement capabilities for documenting scales as small as 1 m and can access reasonably large volumes in and above the atmospheric boundary layer at low cost. The design of the DataHawk system is described, beginning with the atmospheric measurement requirements, and articulating five key challenges that any practical measurement system must overcome. The resulting characteristics of the airborne and ground support components of the DataHawk system are outlined, along with its deployment, operating, and recovery modes. Typical results are presented to illustrate the types and quality of data provided by the current system, as well as the need for more of these finescale measurements. Particular focus is given to the DataHawk's ability to make very-high-resolution measurements of a variety of atmospheric variables simultaneously, with emphasis given to the measurement of two important finescale turbulence parameters, (the temperature turbulence structure constant) and ɛ (the turbulent energy dissipation rate). Future sensing possibilities and limitations using this approach are also discussed.


2021 ◽  
Vol 7 (2) ◽  
pp. 496-499
Author(s):  
Stadler B. Eng. Sebastian ◽  
Herbert Plischke ◽  
Christian Hanshans

Abstract Bioimpedance analysis is a label-free and easy approach to obtain information on cellular barrier integrity and cell viability more broadly. In this work, we introduce a small, low-cost, portable in vitro impedance measurement system for studies where a shadow-free exposure of the cells is a requirement. It can be controlled by a user-friendly web interface and can perform measurements automated and autonomously at short intervals. The system can be integrated into an existing IoT network for remote monitoring and indepth analyses. A single-board computer (SBC) serves as the central unit, to control, analyze, store and forward the measurement data from the single-chip impedance analyzer. Various materials and manufacturing methods were used to produce a purpose-built lid on top of a modified 24-well microtiter plate in a “do it yourself” fashion. Furthermore, three different sensor designs were developed utilizing anodic aluminum oxide (AAO) membranes and gold-plated electrodes. Preliminary tests with potassium chloride (KCl) showed first promising results.


2003 ◽  
Vol 15 (02) ◽  
pp. 61-67 ◽  
Author(s):  
MENG-HSIANG YANG ◽  
K. N. HUANG ◽  
C. F. HUANG ◽  
S. S. HUANG ◽  
M. S. YOUNG

A highly accurate Binary Amplitude-Shift-Keyed (BASK) ultrasonic tremor measurement system for use in isothermal air is developed. In this paper, we present a simple but efficient algorithm based upon phase shifts generated by three ultrasonic waves of different frequencies. By the proposed method, we can conduct larger range measurement than the phase-shift method and also get higher accuracy compared with the time-of-flight (TOF) method. Our microcomputer-based system includes two important parts. One of which is BASK modulation signal generator. The other is a phase meter designed to record and compute the phase shifts of the three different frequencies and the result motion is then sent to either an LCD for display or a PC for calibration. Experiments are done in the laboratory using BASK modulation for the frequencies of 200 Hz and 1 kHz with a 40 kHz carrier. The measurement accuracy of this measurement system in the reported experiments is within +/- 0.98 mm. The main advantages of this ultrasonic tremor measurement system are high resolution, narrow bandwidth requirement, low cost, and easy to be implemented.


2019 ◽  
Author(s):  
Renaud Hage ◽  
Christine Detrembleur ◽  
Frédéric Dierick ◽  
Laurent Pitance ◽  
Laurent Jojczyk ◽  
...  

Various noninvasive measurement devices can be used to assess cervical motion. Size, complexity and cost of gold-standard systems make them not suited in clinical practice, and actually difficult to use outside dedicated laboratory. Nowadays, ultra-low-cost inertial measurement units are available but without any packaging nor user-friendly interface. DYSKIMOT is a home- designed, small-sized, motion sensor based on the latter technology, aiming at being used by clinicians in “real-life situations”. In the present study. DYSKIMOT was compared with a gold- standard optoelectronic system (Elite). Our goal was to evaluate the accuracy of DYSKIMOT in assessing the kinematics in fast head rotations. Kinematics was simultaneously recorded by the DYSKIMOT and Elite systems during the execution of the DidRen Laser test and performed by 15 participants and 9 patients. Kinematic variables were computed from the position, speed and acceleration time series. Two-way ANOVA, Passing-Bablok regressions and Dynamic Time Warping analysis showed good to excellent agreement between Elite and DYSKIMOT, both at the qualitative level of the time series shape and at the quantitative level of peculiar kinematical events’ measured values. In conclusion, DYSKIMOT sensor is as relevant as a gold-standard system to assess kinematical features during fast head rotations in participants and patients, demonstrating its usefulness in clinical practice or research in ecological environment.


Sign in / Sign up

Export Citation Format

Share Document