scholarly journals Auditory Cue Based on the Golden Ratio Can Improve Gait Patterns in People with Parkinson’s Disease

Sensors ◽  
2021 ◽  
Vol 21 (3) ◽  
pp. 911
Author(s):  
Valeria Belluscio ◽  
Marco Iosa ◽  
Giuseppe Vannozzi ◽  
Stefano Paravati ◽  
Antonella Peppe

The harmonic structure of walking relies on an irrational number called the golden ratio (ϕ): in healthy subjects, it coincides with the stride-to-stance ratio, and it is associated with a smooth gait modality. This smoothness is lost in people with Parkinson’s disease (PD), due to deficiencies in the execution of movements. However, external auditory cues seem to facilitate movement, by enabling the timing of muscle activation, and helping in initiating and modulating motor output. Based on a harmonic fractal structure of gait, can the administration of an auditory cue based on individual’s ϕ-rhythm improve, in acute, gait patterns in people with PD? A total of 20 participants (16 males, age 70.9 ± 8.4 years, Hoehn and Yahr stage-II) were assessed through stereophotogrammetry: gait spatio-temporal parameters, and stride-to-stance ratio were computed before, during, and after the ϕ-rhythm administration. Results show improvements in terms of stride length (p = 0.018), walking speed (p = 0.014), and toe clearance (p = 0.013) when comparing gait patterns before and after the stimulus. Furthermore, the stride-to-stance ratio seems to correlate with almost all spatio-temporal parameters, but it shows the main changes in the before–during rhythm comparison. In conclusion, ϕ-rhythm seems an effective cue able to compensate for defective internal rhythm of the basal ganglia in PD.

2021 ◽  
Vol 11 (12) ◽  
pp. 1605
Author(s):  
Tauana Callais Franco do Nascimento ◽  
Flavia Martins Gervásio ◽  
Antonia Pignolo ◽  
Guilherme Augusto Santos Bueno ◽  
Aline Araújo do Carmo ◽  
...  

Introduction: Postural abnormalities are common in patients with Parkinson’s disease (PD) and lead to gait abnormalities. Relationships between changes in the trunk posture of PD patients and gait profile score (GPS) and gait spatiotemporal parameters are poorly investigated. The aim of the current study was to investigate the relationships between trunk posture, GPS, and gait spatiotemporal parameters, in patients with PD. Materials and Methods: Twenty-three people with PD and nineteen age-matched healthy people participated in this study. A 3D gait kinematical analysis was applied to all participants using the Plug-In Gait Full BodyTM tool. Trunk and limb kinematics patterns and gait spatio-temporal parameters of patients with PD and the control group were compared. Additionally, correlations between trunk kinematics patterns, gait spatio-temporal parameters, and GPS of the PD group were tested. Results: Cadence, opposite foot off, step time, single support, double support, foot off, gait speed, trunk kinematics, and GPS showed significant differences between the two groups (p ≤ 0.05). Posture of the trunk during gait was not related to the spatio-temporal parameters and gait profile score in the PD group. The trunk flexor pattern influenced GPS domains, mainly of the ankle and the knee. Discussion and Conclusions: Flexed posture of the trunk in patients with PD seems to influence both ankle and knee movement patterns during the gait. The GPS analysis provided direct and simplified kinematic information for the PD group. These results may have implications for understanding the importance of considering the positioning of the trunk during gait.


Diseases ◽  
2019 ◽  
Vol 7 (1) ◽  
pp. 18 ◽  
Author(s):  
Lorenzo Brognara ◽  
Pierpaolo Palumbo ◽  
Bernd Grimm ◽  
Luca Palmerini

: Parkinson’s disease (PD) is a progressive neurodegenerative disorder. Gait impairments are common among people with PD. Wearable sensor systems can be used for gait analysis by providing spatio-temporal parameters useful to investigate the progression of gait problems in Parkinson disease. However, various methods and tools with very high variability have been developed. The aim of this study is to review published articles of the last 10 years (from 2008 to 2018) concerning the application of wearable sensors to assess spatio-temporal parameters of gait in patients with PD. We focus on inertial sensors used for gait analysis in the clinical environment (i.e., we do not cover the use of inertial sensors to monitor walking or general activities at home, in unsupervised environments). Materials and Methods: Relevant articles were searched in the Medline database using Pubmed. Results and Discussion: Two hundred ninety-four articles were initially identified while searching the scientific literature regarding this topic. Thirty-six articles were selected and included in this review. Conclusion: Wearable motion sensors are useful, non-invasive, low-cost, and objective tools that are being extensively used to perform gait analysis on PD patients. Being able to diagnose and monitor the progression of PD patients makes wearable sensors very useful to evaluate clinical efficacy before and after therapeutic interventions. However, there is no uniformity in the use of wearable sensors in terms of: number of sensors, positioning, chosen parameters, and other characteristics. Future research should focus on standardizing the measurement setup and selecting which spatio-temporal parameters are the most informative to analyze gait in PD. These parameters should be provided as standard assessments in all studies to increase replicability and comparability of results.


2018 ◽  
Vol 10 (2) ◽  
Author(s):  
Massimiliano Pau ◽  
Federica Corona ◽  
Roberta Pili ◽  
Carlo Casula ◽  
Marco Guicciardi ◽  
...  

This study aimed to investigate possible differences in spatio-temporal gait parameters of people with Parkinson’s Disease (pwPD) when they are tested either in laboratory using 3D Gait Analysis or in a clinical setting using wearable accelerometers. The main spatio-temporal gait parameters (speed, cadence, stride length, stance, swing and double support duration) of 31 pwPD were acquired: i) using a wearable accelerometer in a clinical setting while wearing shoes (ISS); ii) same as condition 1, but barefoot (ISB); iii) using an optoelectronic system (OES) undressed and barefoot. While no significant differences were found for cadence, stance, swing and double support duration, the experimental setting affected speed and stride length that decreased (by 17% and 12% respectively, P<0.005) when passing from the clinical (ISS) to the laboratory (OES) setting. These results suggest that gait assessment should be always performed in the same conditions to avoid errors, which may lead to inaccurate patient’s evaluations.


2018 ◽  
Vol 2018 ◽  
pp. 1-10
Author(s):  
Micaela Porta ◽  
Giuseppina Pilloni ◽  
Roberta Pili ◽  
Carlo Casula ◽  
Mauro Murgia ◽  
...  

Background. Although physical activity (PA) is known to be beneficial in improving motor symptoms of people with Parkinson’s disease (pwPD), little is known about the relationship between gait patterns and features of PA performed during daily life. Objective. To verify the existence of possible relationships between spatiotemporal and kinematic parameters of gait and amount/intensity of PA, both instrumentally assessed. Methods. Eighteen individuals affected by PD (10F and 8M, age 68.0 ± 10.8 years, 1.5 ≤ Hoehn and Yahr (H&Y) < 3) were required to wear a triaxial accelerometer 24 h/day for 3 consecutive months. They also underwent a 3D computerized gait analysis at the beginning and end of the PA assessment period. The number of daily steps and PA intensity were calculated on the whole day, and the period from 6:00 to 24:00 was grouped into 3 time slots, using 3 different cut-point sets previously validated in the case of both pwPD and healthy older adults. 3D gait analysis provided spatiotemporal and kinematic parameters of gait, including summary indexes of quality (Gait Profile Score (GPS) and Gait Variable Score (GVS)). Results. The analysis of hourly trends of PA revealed the existence of two peaks located in the morning (approximately at 10) and in the early evening (between 18 and 19). However, during the morning time slot (06:00–12:00), pwPD performed significantly higher amounts of steps (4313 vs. 3437 in the 12:00–18:00 time slot, p<0.001, and vs. 2889 in the 18:00–24:00 time slot, p=0.021) and of moderate-to-vigorous PA (43.2% vs. 36.3% in the 12:00–18:00 time slot, p=0.002, and vs. 31.4% in the 18:00–24:00 time slot, p=0.049). The correlation analysis shows that several PA intensity parameters are significantly associated with swing-phase duration (rho = −0.675 for sedentary intensity, rho = 0.717 for moderate-to-vigorous intensity, p<0.001), cadence (rho = 0.509 for sedentary intensity, rho = −0.575 for moderate-to-vigorous intensity, p<0.05), and overall gait pattern quality as expressed by GPS (rho = −0.498 to −0.606 for moderate intensity, p<0.05) and GVS of knee flexion-extension (rho = −0.536 for moderate intensity, p<0.05). Conclusions. Long-term monitoring of PA integrated by the quantitative assessment of spatiotemporal and kinematic parameters of gait may represent a useful tool in supporting a better-targeted prescription of PA and rehabilitative treatments in pwPD.


Author(s):  
Armando Coccia ◽  
Bernardo Lanzillo ◽  
Leandro Donisi ◽  
Federica Amitrano ◽  
Giuseppe Cesarelli ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document