scholarly journals Laboratory Calibration of Energy Measurement Systems (EMS) under AC Distorted Waveforms

Sensors ◽  
2020 ◽  
Vol 20 (21) ◽  
pp. 6301
Author(s):  
Daniela Istrate ◽  
Abderrahim Khamlichi ◽  
Soureche Soccalingame ◽  
Jorge Rovira ◽  
Dominique Fortune ◽  
...  

Current standard EN 50463-2 indicates the tests and the requirements to be satisfied for an energy measurement system of a traction unit for railway applications. Some of these tests are to be done with several harmonics superposed on the rated voltage, respectively current. However, no calibration systems satisfying the standard requirements were available few years ago. The work performed in the EURAMET project “MyRailS” leads to the development of fictive power sources and reference measurement systems described in this paper. Therefore, it is possible to generate distorted 25 kV-50 Hz voltages with harmonics up to 5 kHz and 90° phase-fired currents up to 500 A with harmonics up to 5 kHz. The generated power is measured by developed traceable reference systems with accuracy better than 0.5%.

Author(s):  
Hanane Saadeddine ◽  
Mohamed Agazar ◽  
Dominique Fortune

Driven by the need for traceable measurement methods, LNE has developed and characterized new reference measurement systems for the calibration of HV impulses, including lightning impulses (1, 2 µs/ 50 µs) and switching impulses (250 µs/ 2500 µs), according to new requirements of IEC 60060-1 and IEC 60060-2. This paper describes new reference measurement systems, which have been developed and fully characterized at LNE. In addition, the paper describes the test procedure for accurate measurements especially for in-situ calibrations in 5 successive steps; measurements of radiofrequency disturbances, step response of voltage dividers, measurement of the scale factors of voltage dividers, calibration of digitizer’s channels and ranges, measurement of the voltage linearity of the divider under calibration up to maximum voltage.


2020 ◽  
Author(s):  
Christa M Cobbaert ◽  
Harald Althaus ◽  
Ilijana Begcevic Brkovic ◽  
Uta Ceglarek ◽  
Stefan Coassin ◽  
...  

Abstract Current dyslipidemia management in patients with atherosclerotic cardiovascular disease (ASCVD) is based on traditional serum lipids. Yet, there is some indication from basic research that serum apolipoproteins A-I, (a), B, C-I, C-II, C-III, and E may give better pathophysiological insight into the root causes of dyslipidemia. To facilitate the future adoption of clinical serum apolipoprotein (apo) profiling for precision medicine, strategies for accurate testing should be developed in advance. Recent discoveries in basic science and translational medicine set the stage for the IFCC Working Group on Apolipoproteins by Mass Spectrometry. Main drivers were the convergence of unmet clinical needs in cardiovascular disease (CVD) patients with enabling technology and metrology. First, the residual cardiovascular risk after accounting for established risk factors demonstrates that the current lipid panel is too limited to capture the full complexity of lipid metabolism in patients. Second, there is a need for accurate test results in highly polymorphic and atherogenic apolipoproteins such as apo(a). Third, sufficient robustness of mass spectrometry technology allows reproducible protein quantification at the molecular level. Fourth, several calibration hierarchies in the revised ISO 17511:2020 guideline facilitate metrological traceability of test results, the highest achievable standard being traceability to SI. This article outlines the conceptual approach aimed at achieving a novel, multiplexed Reference Measurement System (RMS) for seven apolipoproteins based on isotope dilution mass spectrometry and peptide-based calibration. This RMS should enable standardization of existing and emerging apolipoprotein assays to SI, within allowable limits of measurement uncertainty, through a sustainable network of Reference Laboratories.


Agriculture ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 588
Author(s):  
Benjamin C. Smith ◽  
Brett C. Ramirez ◽  
Steven J. Hoff

Many climate-controlled agricultural buildings use direct gas-fired circulating heaters (DGFCH) for supplement heat. There is no standardized test to calculate thermal efficiency for these heaters. This study aimed to develop a measurement system and analytical analysis for thermal efficiency, quantify the measurement uncertainty, and assess economics of DGFCH efficiency. The measurement system developed was similar to the ASHRAE 103 standard test stand with adaptations to connect the apparatus to the DGFCH. Two different propane measurement systems were used: input ratings < 30 kW used a mass flow system and input ratings > 30 kW used a volumetric gas meter. Three DGFCHs (21.9, 29.3, 73.3 kW) were tested to evaluate the system. Thermal efficiencies ranged from 92.4% to 100.9%. The resulting uncertainty (coverage factor of 2; ~95% Confidence Interval) ranged from 13.1% to 30.7% for input ratings of 56.3 to 11.4 kW. Key sources of uncertainty were propane and mass flow of air measurement. The economic impact of 1% difference in thermal efficiency ranged from USD $61.3 to $72.0 per heating season. Refinement of the testing system and procedures are needed to reduce the uncertainty. The application of this system will aid building designers in selection of DGFCHs for various applications.


Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1440
Author(s):  
Yiran Yuan ◽  
Chenglin Wen ◽  
Yiting Qiu ◽  
Xiaohui Sun

There are three state estimation fusion methods for a class of strong nonlinear measurement systems, based on the characteristic function filter, namely the centralized filter, parallel filter, and sequential filter. Under ideal communication conditions, the centralized filter can obtain the best state estimation accuracy, and the parallel filter can simplify centralized calculation complexity and improve feasibility; in addition, the performance of the sequential filter is very close to that of the centralized filter and far better than that of the parallel filter. However, the sequential filter can tolerate non-ideal conditions, such as delay and packet loss, and the first two filters cannot operate normally online for delay and will be invalid for packet loss. The performance of the three designed fusion filters is illustrated by three typical cases, which are all better than that of the most popular Extended Kalman Filter (EKF) performance.


2008 ◽  
Vol 132 (5) ◽  
pp. 838-846
Author(s):  
W. Greg Miller ◽  
Gary L. Myers ◽  
Edward R. Ashwood ◽  
Anthony A. Killeen ◽  
Edward Wang ◽  
...  

Abstract Context.—Harmonization and standardization of results among different clinical laboratories is necessary for clinical practice guidelines to be established. Objective.—To evaluate the state of the art in measuring 10 routine chemistry analytes. Design.—A specimen prepared as off-the-clot pooled sera and 4 conventionally prepared specimens were sent to participants in the College of American Pathologists Chemistry Survey. Analyte concentrations were assigned by reference measurement procedures. Participants.—Approximately 6000 clinical laboratories. Results.—For glucose, iron, potassium, and uric acid, more than 87.5% of peer groups meet the desirable bias goals based on biologic variability criteria. The remaining 6 analytes had less than 52% of peer groups that met the desirable bias criteria. Conclusions.—Routine measurement procedures for some analytes had acceptable traceability to reference systems. Conventionally prepared proficiency testing specimens were not adequately commutable with a fresh frozen specimen to be used to evaluate trueness of methods compared with a reference measurement procedure.


2019 ◽  
pp. 155-168
Author(s):  
Murukesan Loganathan ◽  
Thennarasan Sabapathy ◽  
Mohamed Elobaid Elshaikh ◽  
Mohamed Nasrun Osman ◽  
Rosemizi Abd Rahim ◽  
...  

Efficient collision arbitration protocol facilitates fast tag identification in radio frequency identification (RFID) systems. EPCGlobal-Class1-Generation2 (EPC-C1G2) protocol is the current standard for collision arbitration in commercial RFID systems. However, the main drawback of this protocol is that it requires excessive message exchanges between tags and the reader for its operation. This wastes energy of the already resource-constrained RFID readers. Hence, in this work, reinforcement learning based anti-collision protocol (RL-DFSA) is proposed to address the energy efficient collision arbitration problem in the RFID system. The proposed algorithm continuously learns and adapts to the changes in the environment by devising an optimal policy. The proposed RL-DFSA was evaluated through extensive simulations and compared with the variants of EPC-C1G2 algorithms that are currently being used in the commercial readers. Based on the results, it is concluded that RL-DFSA performs equal or better than EPC-C1G2 protocol in delay, throughput and time system efficiency when simulated for sparse and dense environments while requiring one order of magnitude lesser control message exchanges between the reader and the tags.


2021 ◽  
Vol 2021 ◽  
pp. 1-13
Author(s):  
Lei Xu ◽  
Ning Zhang ◽  
Liqing Fang ◽  
Huadong Chen ◽  
Pengfei Lin ◽  
...  

The magnetic gradient full-tensor measurement system is diverse, and the magnetometer array structure is complex. Aimed at the problem, seven magnetic gradient full-tensor measurement system models are studied in detail. The full-tensor measurement theories of the tensor measurement arrays are analyzed. Under the same baseline distance, the magnetic dipole model is used to simulate the measurement system. Based on different measurement systems, the paper quantitatively compares and analyzes the error of the structure. A more optimized magnetic gradient full-tensor measurement system is suggested. The simulation results show that the measurement accuracy of the planar measurement system is slightly higher than that of the stereo measurement system. Among them, the cross-shaped and square measurement systems have relatively smaller structural errors and higher measurement accuracy.


Author(s):  
Алексей Николаевич Самойлов ◽  
Юрий Михайлович Бородянский ◽  
Александр Валерьевич Волошин

В процессе автоматизации решения прикладных измерительных задач, в том числе на базе фотограмметрических методов, возникает проблема соответствия измерительной системы объекту и условиям измерения. Для того чтобы измерительная система позволяла заранее оценить возможность получения достоверных результатов, а также наилучшим образом подстраивалась под условия измерения, необходимо наличие специализированных алгоритмов и моделей. В общем случае такие модели ориентированы на квалифицированных технических специалистов, обладающих необходимыми знаниями в области информационных технологий. Особенностью применения фотограмметрических измерительных систем в лесной и металлургической промышленности является низкая квалификация пользователей в сфере информационных технологий, что обуславливается характером выполняемых работ и условиями привлечения. Данный фактор не позволяет решить задачу подстройки системы традиционными методами, в которых процессом настройки управляет пользователь. В этой связи в статье предлагается модель и алгоритм формирования измерительной системы по первичным входным данным, в котором процессом настройки управляет сама система. In the process of automating the solution of applied measurement tasks, including on the basis of photogrammetric methods, there is a problem of compliance of the measurement system with the object and measurement conditions. In order for the measuring system to assess in advance the possibility of obtaining reliable results, as well as to best adapt to the conditions of measurement, it is necessary to have specialized algorithms and models. In general, such models are aimed at qualified technicians with the necessary knowledge in the field of information technology. A feature of the application of photogrammetric measurement systems in the forestry and metallurgical industry is the low qualification of users in the field of information technology, which is determined by the nature of the work performed and the conditions of attraction. This factor does not solve the problem of adjusting the system by traditional methods in which the user controls the configuration process. In this regard, the article proposes a model and algorithm for forming a measuring system from primary input data, in which the system itself controls the adjustment process.