scholarly journals Impedimetric Determination of Kanamycin in Milk with Aptasensor Based on Carbon Black-Oligolactide Composite

Sensors ◽  
2020 ◽  
Vol 20 (17) ◽  
pp. 4738 ◽  
Author(s):  
Tatiana Kulikova ◽  
Vladimir Gorbatchuk ◽  
Ivan Stoikov ◽  
Alexey Rogov ◽  
Gennady Evtugyn ◽  
...  

The determination of antibiotics in food is important due to their negative effect on human health related to antimicrobial resistance problem, renal toxicity, and allergic effects. We propose an impedimetric aptasensor for the determination of kanamycin A (KANA), which was assembled on the glassy carbon electrode by the deposition of carbon black in a chitosan matrix followed by carbodiimide binding of aminated aptamer mixed with oligolactide derivative of thiacalix[4]arene in a cone configuration. The assembling was monitored by cyclic voltammetry, electrochemical impedance spectroscopy, and scanning electron microscopy. In the presence of the KANA, the charge transfer resistance of the inner interface surprisingly decreased with the analyte concentration within 0.7 and 50 nM (limit of detection 0.3 nM). This was attributed to the partial shielding of the negative charge of the aptamer and of its support, a highly porous 3D structure of the surface layer caused by a macrocyclic core of the carrier. The use of electrostatic assembling in the presence of cationic polyelectrolyte decreased tenfold the detectable concentration of KANA. The aptasensor was successfully tested in the determination of KANA in spiked milk and yogurt with recoveries within 95% and 115%.

Nanomaterials ◽  
2020 ◽  
Vol 10 (5) ◽  
pp. 924
Author(s):  
Anna Porfireva ◽  
Gennady Evtugyn

A DNA sensor has been developed for the determination of doxorubicin by consecutive electropolymerization of an equimolar mixture of Azure B and proflavine and adsorption of native DNA from salmon sperm on a polymer film. Electrochemical investigation showed a difference in the behavior of individual drugs polymerized and their mixture. The use of the copolymer offered some advantages, i.e., a higher roughness of the surface, a wider range of the pH sensitivity of the response, a denser and more robust film, etc. The formation of the polymer film and its redox properties were studied using scanning electron microscopy and electrochemical impedance spectroscopy. For the doxorubicin determination, its solution was mixed with DNA and applied on the polymer surface. After that, charge transfer resistance was assessed in the presence of [Fe(CN)6]3−/4− as the redox probe. Its value regularly grew with the doxorubicin concentration in the range from 0.03 to 10 nM (limit of detection 0.01 nM). The DNA sensor was tested on the doxorubicin preparations and spiked samples mimicking blood serum. The recovery was found to be 98–106%. The DNA sensor developed can find application for the determination of drug residues in blood and for the pharmacokinetics studies.


Sensors ◽  
2021 ◽  
Vol 21 (6) ◽  
pp. 1929
Author(s):  
Alexander Rodríguez ◽  
Francisco Burgos-Flórez ◽  
José D. Posada ◽  
Eliana Cervera ◽  
Valtencir Zucolotto ◽  
...  

Neuronal damage secondary to traumatic brain injury (TBI) is a rapidly evolving condition, which requires therapeutic decisions based on the timely identification of clinical deterioration. Changes in S100B biomarker levels are associated with TBI severity and patient outcome. The S100B quantification is often difficult since standard immunoassays are time-consuming, costly, and require extensive expertise. A zero-length cross-linking approach on a cysteamine self-assembled monolayer (SAM) was performed to immobilize anti-S100B monoclonal antibodies onto both planar (AuEs) and interdigitated (AuIDEs) gold electrodes via carbonyl-bond. Surface characterization was performed by atomic force microscopy (AFM) and specular-reflectance FTIR for each functionalization step. Biosensor response was studied using the change in charge-transfer resistance (Rct) from electrochemical impedance spectroscopy (EIS) in potassium ferrocyanide, with [S100B] ranging 10–1000 pg/mL. A single-frequency analysis for capacitances was also performed in AuIDEs. Full factorial designs were applied to assess biosensor sensitivity, specificity, and limit-of-detection (LOD). Higher Rct values were found with increased S100B concentration in both platforms. LODs were 18 pg/mL(AuES) and 6 pg/mL(AuIDEs). AuIDEs provide a simpler manufacturing protocol, with reduced fabrication time and possibly costs, simpler electrochemical response analysis, and could be used for single-frequency analysis for monitoring capacitance changes related to S100B levels.


2001 ◽  
Vol 66 (11-12) ◽  
pp. 871-880 ◽  
Author(s):  
Vesna Miskovic-Stankovic ◽  
Zorica Lazarevic ◽  
Zorica Kacarevic-Popovic

The corrosion behaviour of epoxy coatings electrodeposited on aluminium, as well as on electrochemically and chemically modified aluminium were investigated during exposure to 3 % NaCl. Electrochemical impedance spectroscopy (EIS) and thermogravimetric analysis (TGA) were used for the determination of the protective properties of epoxy coatings on aluminium, anodized aluminium, phosphatized and chromatized-phosphatized aluminium. The protective properties of epoxy coatings on anodized and chromatized-phosphatized aluminium are significantly improved with respect to the same epoxy coatings on aluminium and phosphatized aluminium: higher values of the pore resitance and charge-transfer resistance, lower values of the coating capacitance, double-layer capacitance and relative permittivity (from EIS) smaller amount of absorbed water inside the coating (From TGA). On the other hand, the lower values of the ipdt temperature indicate a lower thermal stability of the epoxy coatings on anodized and chromatized-phosphatized aluminium.


Biosensors ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 287
Author(s):  
Maria A. Bukharinova ◽  
Natalia Yu. Stozhko ◽  
Elizaveta A. Novakovskaya ◽  
Ekaterina I. Khamzina ◽  
Aleksey V. Tarasov ◽  
...  

The paper describes the development of a carbon veil-based electrode (CVE) for determining uric acid (UA) in saliva. The electrode was manufactured by lamination technology, electrochemically activated and used as a highly sensitive voltammetric sensor (CVEact). Potentiostatic polarization of the electrode at 2.0 V in H2SO4 solution resulted in a higher number of oxygen and nitrogen-containing groups on the electrode surface; lower charge transfer resistance; a 1.5 times increase in the effective surface area and a decrease in the UA oxidation potential by over 0.4 V, compared with the non-activated CVE, which was confirmed by energy dispersive X-ray spectroscopy, electrochemical impedance spectroscopy, chronoamperometry and linear sweep voltammetry. The developed sensor is characterized by a low detection limit of 0.05 µM and a wide linear range (0.09–700 µM). The results suggest that the sensor has perspective applications for quick determination of UA in artificial and human saliva. RSD does not exceed 3.9%, and recovery is 96–105%. UA makes a significant contribution to the antioxidant activity (AOA) of saliva (≈60%). In addition to its high analytical characteristics, the important advantages of the proposed CVEact are the simple, scalable, and cost-effective manufacturing technology and the absence of additional complex and time-consuming modification operations.


2020 ◽  
Vol 20 (11) ◽  
pp. 7163-7168
Author(s):  
Huynh Vu Nguyen ◽  
Anna Go ◽  
Min-Ho Lee

A label-free electrochemical impedimetric immunosensor for the detection of Triiodothyronine—a thyroid hormone that functions as the biomarker for monitoring for thyroid dysfunction was developed. The gold nanoparticle-modified electrode was employed to achieve the sensitive determination of Triiodothyronine at a low concentration level. The gold nanoparticle layer on the gold electrode was generated by chronoamperometry method and its resulting characteristics were investigated by scanning electron microscopy. Redox probe [Fe(CN)6]3−/4− and electrochemical impedance spec-troscopy was used for both evaluation of the immobilization of anti-Triiodothyronine antibody on the electrode surface and quantitative determination of target Triiodothyronine in different concentrations. The electrode with absorbed antibodies showed significant changes in charge transfer resistance upon binding the antigen, which resulted in an increase in normalized impedance change as the addition of antigen concentrations over a dynamic linear range of 0.01–100 ng/ml. These results indicated that the proposed immunosensor could be a potential alternative method for determination of Triiodothyronine in clinics with the advantage of low cost and less time-consuming.


Author(s):  
Mahmoud Fatehy Abdalqader Altahan ◽  
Eric Achterberg ◽  
Asmaa Galal ◽  
Magdi Abdel Azzem

Abstract Here we describe a new electrochemical sensor for PO4 3− detection in seawater. In this work, we prepared a carbon paste electrode (CPE) modified with molybdate and pretreated in 0.1 M NaOH using cyclic voltammetry (CV). The modified CPE was employed for the determination of PO4 3− in artificial seawater (35 g/L NaCl) acidified with sulfuric acid to pH 0.8. An additional cleaning step (cyclic voltammetry (CV)) of 10 cycles in 0.1 M NaOH at −0.5 to 0.5 V was required between PO4 3− determinations to dissolve the phosphomolybdic complex formed on the surface of the working electrode. Electrochemical impedance spectroscopy (EIS) results confirmed that the molybdate-modified CPE (molybdate/CPE) exhibited a low charge-transfer resistance (Rct) toward PO4 3−, and showed an improved analytical performance for different concentrations of PO4 3−. A calibration plot in the range of 0.01–5 µM with a limit of detection (LOD) of 0.003 µM was obtained. The proposed electrode demonstrated good precision (4.3% and 5.8%) for concentrations of 5 and 0.2 µM, respectively. The proposed method was employed to analyze PO4 3− in seawater samples on a research cruise in the North Sea, with results in close agreement to those obtained using conventional colorimetric measuremen


2021 ◽  
Vol 49 (1) ◽  
pp. 1-8
Author(s):  
Zoltán Lukács ◽  
Dávid Baccilieri ◽  
Tamás Kristóf

The determination of typical parameters of electrochemical systems, e.g. the polarization or charge transfer resistances, can be critical with regard to the application of Electrochemical Impedance Spectroscopy (EIS) if the lower frequency range is biased as a result of transport and/or adsorption/desorption processes. In such cases, the charge transfer resistance should be assessed from the higher frequency range which is typically inadequate in itself as an input for nonlinear parameter fitting. In earlier publications, an alternative mathematical treatment of both the Equivalent Circuit (EC) and of the parameter dispersion was provided using a generalized model of ECs and also a dispersion-invariant model of the electrochemical interface. In the present work, the previously presented experimental EIS results were crosschecked to verify the performance of the generalized model against a series of redox and corrosion systems. The results proved that the applied method is consistent and provides a fairly good correlation between the principal resistance data assessed by different methods.


2021 ◽  
Vol 188 (10) ◽  
Author(s):  
Radosław Porada ◽  
Katarzyna Fendrych ◽  
Bogusław Baś

Abstract The utilization of environmentally friendly nanoporous natural zeolite exchanged with Ni2+ ions (NiZ) and conductive carbon black (CB) in the fabrication of a novel and selective voltammetric sensor of vitamin B6 (VB6) is presented. The used clinoptilolite-rich zeolite material and CB were characterized in terms of morphology and textural properties. The superior properties of Ni-zeolite/carbon black modified glassy carbon electrode (NiZCB-GCE), arising from the synergistic effect of combining the unique features of zeolite and conductive carbon black, were confirmed by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) measurements. In the determination of VB6 with the use of differential pulse voltammetry (DPV), the optimization of the pH value of supporting electrolyte and instrumental parameters, as well as the interference study were performed. Under optimized conditions, the oxidation peak current at the potential +0.72 V vs. Ag | AgCl | 3 M KCl reference electrode was linear to the VB6 concentration in the range 0.050 to 1.0 mg L−1 (0.30–5.9 μmol L−1) (R = 0.9993). The calculated limit of detection (LOD, S/N = 3), equal to 15 μg L−1 (0.09 μmol L−1), was much better compared to chemically modified electrodes with other carbon-based materials. The RSD for 0.5 mg L−1 was in the range 2.5–5.4% (n = 4). The developed NiZCB-GCE was successfully applied to the determination of VB6 in commercially available multivitamin dietary supplements, food, and water samples. The obtained recoveries ranged from 95 to 106%. Graphical abstract


2021 ◽  
Vol 26 (1) ◽  
pp. 8-21
Author(s):  
Emad A. Khudaish ◽  
Arwa Al-Maskari

A solid-state sensor was fabricated by a spontaneous electrochemical deposition of polytyramine (Ptyr) film onto a glassy carbon electrode (GCE) which was further peripherally supported by gold nanoparticles (AuNPs). The surface materials of the developed sensor (AuNPs.Ptyr-GCE) were characterized by X-ray photoelectron spectroscopy (XPS), electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The rate constant of charge transfers (kct) of the as-prepared sensor (8.77 × 10-4 cm/s) was evaluated by fitting the charge transfer resistance (Rct) data in the presence of ferric-ferrous hexacyanide redox couple solution, [Fe(CN)6]3-/4-. The voltammetric behavior of norepinephrine (NOR) was confirmed to follow an irreversible reaction mechanism at which the estimated diffusion coefficient value was 7.39 × 10-5 cm2/s. The sensor showed a large enhancement on NOR oxidation and comparatively lowered its detection limit (DL3s) to 0.130 mM (22 ppb). It was also applied for selective determination of NOR in the presence of high concentrations of ascorbic acid (AA) and uric acid (UA). The interference study highlighted the great stability of the proposed sensor by generating a similar sensitivity as in the pure NOR solution. The analytical performance of the proposed system was validated successfully for pharmaceutical and biological samples with tolerable recovery percentages.


Micromachines ◽  
2019 ◽  
Vol 10 (9) ◽  
pp. 575 ◽  
Author(s):  
Gorachand Dutta ◽  
Abdoulie A. Jallow ◽  
Debjani Paul ◽  
Despina Moschou

This paper reports for the first time printed-circuit-board (PCB)-based label-free electrochemical detection of bacteria. The demonstrated immunosensor was implemented on a PCB sensing platform which was designed and fabricated in a standard PCB manufacturing facility. Bacteria were directly captured on the PCB sensing surface using a specific, pre-immobilized antibody. Electrochemical impedance spectra (EIS) were recorded and used to extract the charge transfer resistance (Rct) value for the different bacteria concentrations under investigation. As a proof-of-concept, Streptococcus mutans (S. mutans) bacteria were quantified in a phosphate buffered saline (PBS) buffer, achieving a limit of detection of 103 CFU/mL. Therefore, the proposed biosensor is an attractive candidate for the development of a simple and robust point-of-care diagnostic platform for bacteria identification, exhibiting good sensitivity, high selectivity, and excellent reproducibility.