scholarly journals Field Evaluation of Low-Cost Particulate Matter Sensors in Beijing

Sensors ◽  
2020 ◽  
Vol 20 (16) ◽  
pp. 4381 ◽  
Author(s):  
Han Mei ◽  
Pengfei Han ◽  
Yinan Wang ◽  
Ning Zeng ◽  
Di Liu ◽  
...  

Numerous particulate matter (PM) sensors with great development potential have emerged. However, whether the current sensors can be used for reliable long-term field monitoring is unclear. This study describes the research and application prospects of low-cost miniaturized sensors in PM2.5 monitoring. We evaluated five Plantower PMSA003 sensors deployed in Beijing, China, over 7 months (October 2019 to June 2020). The sensors tracked PM2.5 concentrations, which were compared to the measurements at the national control monitoring station of the Ministry of Ecology and Environment (MEE) at the same location. The correlations of the data from the PMSA003 sensors and MEE reference monitors (R2 = 0.83~0.90) and among the five sensors (R2 = 0.91~0.98) indicated a high accuracy and intersensor correlation. However, the sensors tended to underestimate high PM2.5 concentrations. The relative bias reached −24.82% when the PM2.5 concentration was >250 µg/m3. Conversely, overestimation and high errors were observed during periods of high relative humidity (RH > 60%). The relative bias reached 14.71% at RH > 75%. The PMSA003 sensors performed poorly during sand and dust storms, especially for the ambient PM10 concentration measurements. Overall, this study identified good correlations between PMSA003 sensors and reference monitors. Extreme field environments impact the data quality of low-cost sensors, and future corrections remain necessary.

2019 ◽  
Vol 245 ◽  
pp. 932-940 ◽  
Author(s):  
T. Sayahi ◽  
A. Butterfield ◽  
K.E. Kelly

2020 ◽  
Vol 20 (2) ◽  
pp. 242-253 ◽  
Author(s):  
Lu Bai ◽  
Lin Huang ◽  
Zhenglu Wang ◽  
Qi Ying ◽  
Jun Zheng ◽  
...  

Gefahrstoffe ◽  
2019 ◽  
Vol 79 (11-12) ◽  
pp. 443-450
Author(s):  
P. Bächler ◽  
J. Meyer ◽  
A. Dittler

The reduction of fine dust emissions with pulse-jet cleaned filters plays an important role in industrial gas cleaning to meet emission standards and protect the environment. The dust emission of technical facilities is typically measured “end of pipe”, so that no information about the local emission contribution of individual filter elements exists. Cheap and compact low-cost sensors for the detection of particulate matter (PM) concentrations, which have been prominently applied for immission monitoring in recent years have the potential for emission measurement of filters to improve process monitoring. This publication discusses the suitability of a low-cost PM-sensor, the model SPS30 from the manufacturer Sensirion, in terms of the potential for particle emission measurement of surface filters in a filter test rig based on DIN ISO 11057. A Promo® 2000 in combination with a Welas® 2100 sensor serves as the optical reference device for the evaluation of the detected PM2.5 concentration and particle size distribution of the emission measured by the low-cost sensor. The Sensirion sensor shows qualitatively similar results of the detected PM2.5 emission as the low-cost sensor SDS011 from the manufacturer Nova Fitness, which was investigated by Schwarz et al. in a former study. The typical emission peak after jet-pulse cleaning of the filter, due to the penetration of particles through the filter medium, is detected during Δp-controlled operation. The particle size distribution calculated from the size resolved number concentrations of the low-cost sensor yields a distinct distribution for three different employed filter media and qualitatively fits the size distribution detected by the Palas® reference. The emission of these three different types of filter media can be distinguished clearly by the measured PM2.5 concentration and the emitted mass per cycle and filter area, demonstrating the potential for PM emission monitoring by the low-cost PM-sensor. During the period of Δt-controlled filter aging, a decreasing emission, caused by an increasing amount of stored particles in the filter medium, is detected. Due to the reduced particle emission after filter aging, the specified maximum concentration of the low-cost sensor is not exceeded so that coincidence is unlikely to affect the measurement results of the sensor for all but the very first stage of filter life.


Author(s):  
Kaja Karczewska ◽  
Leszek Kolendowicz ◽  
Marek Półrolniczak ◽  
Hanna Forycka–Ławniczak

The subject of the paper is the influence of atmospheric circulation on the content of suspended PM10 in the air in Konin. For this purpose dust concentrations from the period 2012–2016 were generally characterized. PM10 particulate matter concentration average hourly data were obtained from the Main Inspectorate of Environmental Protection website. Based on these data, long-term, seasonal and daily changes in the PM10 concentration in the atmosphere were investigated. The study analysed the daily variability of the PM10 suspended particulate matter concentration to present seasonal differences (in hot and cold seasons). In order to determine the influence of atmospheric circulation on the PM10 particulate matter concentration, the concentration levels data were compared with the types of circulation prevailing on the same day. In this study according to synoptic maps the days with maximum and minimum concentrations PM levels were analysed. It was found which type of meteorological circulation is conducive to higher levels concentrations of particulate matter PM10, and which has a positive effect on the quality of the air in Konin.


Sensors ◽  
2020 ◽  
Vol 20 (24) ◽  
pp. 7290
Author(s):  
Miron Kaliszewski ◽  
Maksymilian Włodarski ◽  
Jarosław Młyńczak ◽  
Krzysztof Kopczyński

This study shows the results of air monitoring in high- and low-occupancy rooms using two combinations of sensors, AeroTrak8220(TSI)/OPC-N3 (AlphaSense, Great Notley, UK) and OPC-N3/PMS5003 (Plantower, Beijing, China), respectively. The tests were conducted in a flat in Warsaw during the restrictions imposed due to the COVID-19 lockdown. The results showed that OPC-N3 underestimates the PN (particle number concentration) by about 2–3 times compared to the AeroTrak8220. Subsequently, the OPC-N3 was compared with another low-cost sensor, the PMS5003. Both devices showed similar efficiency in PN estimation, whereas PM (particulate matter) concentration estimation differed significantly. Moreover, the relationship among the PM1–PM2.5–PM10 readings obtained with the PMS5003 appeared improbably linear regarding the natural indoor conditions. The correlation of PM concentrations obtained with the PMS5003 suggests an oversimplified calculation method of PM. The studies also demonstrated that PM1, PM2.5, and PM10 concentrations in the high- to low-occupancy rooms were about 3, 2, and 1.5 times, respectively. On the other hand, the use of an air purifier considerably reduced the PM concentrations to similar levels in both rooms. All the sensors showed that frying and toast-making were the major sources of particulate matter, about 10 times higher compared to average levels. Considerably lower particle levels were measured in the low-occupancy room.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Florentin M. J. Bulot ◽  
Steven J. Johnston ◽  
Philip J. Basford ◽  
Natasha H. C. Easton ◽  
Mihaela Apetroaie-Cristea ◽  
...  

An amendment to this paper has been published and can be accessed via a link at the top of the paper.


2018 ◽  
Vol 28 (4) ◽  
pp. 365-373 ◽  
Author(s):  
Alexander Persoskie ◽  
Elisabeth A Donaldson ◽  
Chase Ryant

IntroductionPackage quantity refers to the number of cigarettes or amount of other tobacco product in a package. Many countries restrict minimum cigarette package quantities to avoid low-cost packs that may lower barriers to youth smoking.MethodsWe reviewed Truth Tobacco Industry Documents to understand tobacco companies’ rationales for introducing new package quantities, including companies’ expectations and research regarding how package quantity may influence consumer behaviour. A snowball sampling method (phase 1), a static search string (phase 2) and a follow-up snowball search (phase 3) identified 216 documents, mostly from the 1980s and 1990s, concerning cigarettes (200), roll-your-own tobacco (9), smokeless tobacco (6) and ‘smokeless cigarettes’ (1).ResultsCompanies introduced small and large packages to motivate brand-switching and continued use among current users when faced with low market share or threats such as tax-induced price increases or competitors’ use of price promotions. Companies developed and evaluated package quantities for specific brands and consumer segments. Large packages offered value-for-money and matched long-term, heavy users’ consumption rates. Small packages were cheaper, matched consumption rates of newer and lighter users, and increased products’ novelty, ease of carrying and perceived freshness. Some users also preferred small packages as a way to try to limit consumption or quit.ConclusionIndustry documents speculated about many potential effects of package quantity on appeal and use, depending on brand and consumer segment. The search was non-exhaustive, and we could not assess the quality of much of the research or other information on which the documents relied.


2003 ◽  
Vol 24 (1) ◽  
pp. 83-103 ◽  
Author(s):  
Chessa K. Lutter

Large numbers of infants and young children suffer from the short- and long-term health effects of poor breastfeeding and complementary feeding practices. Strategies to improve the availability of and access to low-cost fortified complementary foods can play an important corresponding role to that of behavior change in improving nutritional status of young children. However, the nutritional quality of complementary foods used in publicly funded programs is not always optimal, and such programs are costly and reach only a tiny fraction of those who could benefit. To broadly reach the target population, such foods need to be commercially available at affordable prices and promoted in a way that generates demand for their purchase. A sensible long-term policy for the promotion of low-cost fortified complementary foods calls for attention to their nutritional formulations and cost, the economics of production, and the legislative, regulatory, and competitive framework in which marketing occurs. This paper provides information on how to improve the nutritional formulations of fortified complementary foods and outlines the necessary conditions for a market approach to their production and promotion.


2014 ◽  
Vol 14 (24) ◽  
pp. 13411-13422 ◽  
Author(s):  
P. Dagsson-Waldhauserova ◽  
O. Arnalds ◽  
H. Olafsson

Abstract. The long-term frequency of atmospheric dust observations was investigated for the southern part of Iceland and interpreted together with earlier results obtained from northeastern (NE) Iceland (Dagsson-Waldhauserova et al., 2013). In total, over 34 dust days per year on average occurred in Iceland based on conventionally used synoptic codes for dust observations. However, frequent volcanic eruptions, with the re-suspension of volcanic materials and dust haze, increased the number of dust events fourfold (135 dust days annually). The position of the Icelandic Low determined whether dust events occurred in the NE (16.4 dust days annually) or in the southern (S) part of Iceland (about 18 dust days annually). The decade with the most frequent dust days in S Iceland was the 1960s, but the 2000s in NE Iceland. A total of 32 severe dust storms (visibility < 500 m) were observed in Iceland with the highest frequency of events during the 2000s in S Iceland. The Arctic dust events (NE Iceland) were typically warm, occurring during summer/autumn (May–September) and during mild southwesterly winds, while the subarctic dust events (S Iceland) were mainly cold, occurring during winter/spring (March–May) and during strong northeasterly winds. About half of the dust events in S Iceland occurred in winter or at sub-zero temperatures. A good correlation was found between particulate matter (PM10) concentrations and visibility during dust observations at the stations Vík and Stórhöfði. This study shows that Iceland is among the dustiest areas of the world and that dust is emitted year-round.


Sensors ◽  
2021 ◽  
Vol 21 (18) ◽  
pp. 6036
Author(s):  
Vincenzo Randazzo ◽  
Jacopo Ferretti ◽  
Eros Pasero

Every year cardiovascular diseases kill the highest number of people worldwide. Among these, pathologies characterized by sporadic symptoms, such as atrial fibrillation, are difficult to be detected as state-of-the-art solutions, e.g., 12-leads electrocardiogram (ECG) or Holter devices, often fail to tackle these kinds of pathologies. Many portable devices have already been proposed, both in literature and in the market. Unfortunately, they all miss relevant features: they are either not wearable or wireless and their usage over a long-term period is often unsuitable. In addition, the quality of recordings is another key factor to perform reliable diagnosis. The ECG WATCH is a device designed for targeting all these issues. It is inexpensive, wearable (size of a watch), and can be used without the need for any medical expertise about positioning or usage. It is non-invasive, it records single-lead ECG in just 10 s, anytime, anywhere, without the need to physically travel to hospitals or cardiologists. It can acquire any of the three peripheral leads; results can be shared with physicians by simply tapping a smartphone app. The ECG WATCH quality has been tested on 30 people and has successfully compared with an electrocardiograph and an ECG simulator, both certified. The app embeds an algorithm for automatically detecting atrial fibrillation, which has been successfully tested with an official ECG simulator on different severity of atrial fibrillation. In this sense, the ECG WATCH is a promising device for anytime cardiac health monitoring.


Sign in / Sign up

Export Citation Format

Share Document