scholarly journals A Highly Sensitive Impedimetric DNA Biosensor Based on Hollow Silica Microspheres for Label-Free Determination of E. coli

Sensors ◽  
2020 ◽  
Vol 20 (5) ◽  
pp. 1279 ◽  
Author(s):  
Eda Yuhana Ariffin ◽  
Lee Yook Heng ◽  
Ling Ling Tan ◽  
Nurul Huda Abd Karim ◽  
Siti Aishah Hasbullah

A novel label-free electrochemical DNA biosensor was constructed for the determination of Escherichia coli bacteria in environmental water samples. The aminated DNA probe was immobilized onto hollow silica microspheres (HSMs) functionalized with 3-aminopropyltriethoxysilane and deposited onto a screen-printed electrode (SPE) carbon paste with supported gold nanoparticles (AuNPs). The biosensor was optimized for higher specificity and sensitivity. The label-free E. coli DNA biosensor exhibited a dynamic linear response range of 1 × 10−10 µM to 1 × 10−5 µM (R2 = 0.982), with a limit of detection at 1.95 × 10−15 µM, without a redox mediator. The sensitivity of the developed DNA biosensor was comparable to the non-complementary and single-base mismatched DNA. The DNA biosensor demonstrated a stable response up to 21 days of storage at 4 ℃ and pH 7. The DNA biosensor response was regenerable over three successive regeneration and rehybridization cycles.

Nanomaterials ◽  
2020 ◽  
Vol 10 (3) ◽  
pp. 537 ◽  
Author(s):  
Chrys. O. Chikere ◽  
Nadimul Haque Faisal ◽  
Paul Kong-Thoo-Lin ◽  
Carlos Fernandez

Amorphous zirconium oxide nanoparticles (ZrO2) have been used for the first time, to modify carbon paste electrode (CPE) and used as a sensor for the electrochemical determination of gallic acid (GA). The voltammetric results of the ZrO2 nanoparticles-modified CPE showed efficient electrochemical oxidation of gallic acid, with a significantly enhanced peak current from 261 µA ± 3 to about 451 µA ± 1. The modified surface of the electrode and the synthesised zirconia nanoparticles were characterised by scanning electrode microscopy (SEM), Energy-dispersive x-ray spectroscopy (EDXA), X-ray powdered diffraction (XRD) and Fourier-transform infrared spectroscopy (FTIR). Meanwhile, the electrochemical behaviour of GA on the surface of the modified electrode was studied using differential pulse voltammetry (DPV), showing a sensitivity of the electrode for GA determination, within a concentration range of 1 × 10−6 mol L−1 to 1 × 10−3 mol L−1 with a correlation coefficient of R2 of 0.9945 and a limit of detection of 1.24 × 10−7 mol L−1 (S/N = 3). The proposed ZrO2 nanoparticles modified CPE was successfully used for the determination of GA in red and white wine, with concentrations of 0.103 mmol L−1 and 0.049 mmol L−1 respectively.


2020 ◽  
Vol 187 (5) ◽  
Author(s):  
Jagriti Sethi ◽  
Michiel Van Bulck ◽  
Ahmed Suhail ◽  
Mina Safarzadeh ◽  
Ana Perez-Castillo ◽  
...  

AbstractA label-free biosensor is developed for the determination of plasma-based Aβ1–42 biomarker in Alzheimer’s disease (AD). The platform is based on highly conductive dual-layer of graphene and electrochemically reduced graphene oxide (rGO). The modification of dual-layer with 1-pyrenebutyric acid N-hydroxysuccinimide ester (Pyr-NHS) is achieved to facilitate immobilization of H31L21 antibody. The effect of these modifications were studied with morphological, spectral and electrochemical techniques. The response of the biosensor was evaluated using differential pulse voltammetry (DPV). The data was acquired at a working potential of ~ 180 mV and a scan rate of 50 mV s−1. A low limit of detection (LOD) of 2.398 pM is achieved over a wide linear range from 11 pM to 55 nM. The biosensor exhibits excellent specificity over Aβ1–40 and ApoE ε4 interfering species. Thus, it provides a viable tool for electrochemical determination of Aβ1–42. Spiked human and mice plasmas were used for the successful validation of the sensing platform in bio-fluidic samples. The results obtained from mice plasma analysis concurred with the immunohistochemistry (IHC) and magnetic resonance imaging (MRI) data obtained from brain analysis.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Mona Yaghoubi ◽  
Fereshteh Rahimi ◽  
Babak Negahdari ◽  
Ali Hossein Rezayan ◽  
Azizollah Shafiekhani

Abstract Accuracy and speed of detection, along with technical and instrumental simplicity, are indispensable for the bacterial detection methods. Porous silicon (PSi) has unique optical and chemical properties which makes it a good candidate for biosensing applications. On the other hand, lectins have specific carbohydrate-binding properties and are inexpensive compared to popular antibodies. We propose a lectin-conjugated PSi-based biosensor for label-free and real-time detection of Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus) by reflectometric interference Fourier transform spectroscopy (RIFTS). We modified meso-PSiO2 (10–40 nm pore diameter) with three lectins of ConA (Concanavalin A), WGA (Wheat Germ Agglutinin), and UEA (Ulex europaeus agglutinin) with various carbohydrate specificities, as bioreceptor. The results showed that ConA and WGA have the highest binding affinity for E. coli and S. aureus respectively and hence can effectively detect them. This was confirmed by 6.8% and 7.8% decrease in peak amplitude of fast Fourier transform (FFT) spectra (at 105 cells mL−1 concentration). A limit of detection (LOD) of about 103 cells mL−1 and a linear response range of 103 to 105 cells mL−1 were observed for both ConA-E. coli and WGA-S. aureus interaction platforms that are comparable to the other reports in the literature. Dissimilar response patterns among lectins can be attributed to the different bacterial cell wall structures. Further assessments were carried out by applying the biosensor for the detection of Klebsiella aerogenes and Bacillus subtilis bacteria. The overall obtained results reinforced the conjecture that the WGA and ConA have a stronger interaction with Gram-positive and Gram-negative bacteria, respectively. Therefore, it seems that specific lectins can be suggested for bacterial Gram-typing or even serotyping. These observations were confirmed by the principal component analysis (PCA) model.


2019 ◽  
Vol 0 (0) ◽  
Author(s):  
T. Venu Gopal ◽  
Tukiakula Madhusudana Reddy ◽  
P. Shaikshavali ◽  
G. Venkataprasad ◽  
P. Gopal

Abstract A small scale of environmentally hazardous 4-aminophenol can show significant impact on human health. Hence, in the present work, we have designed L-Valine film (Vf) modified carbon paste electrode (Vf/CPE) for the determination of 4-aminophenol. Herein, a facile in-situ L-Valine film was developed by electrochemical polymerization method onto the surface of bare carbon paste electrode (BCPE) with the help of cyclic voltammetry (CV) technique. A two-folds of electrochemical peak current enhancement was achieved at Vf/CPE in comparison with BCPE towards the determination of 4-aminophenol in optimum pH 7.0 of phosphate buffer solution (PBS). This was achieved due to the large surface area and conductive nature of Vf/CPE, which was concluded through the techniques of cyclic voltammetry and electrochemical impedance spectroscopy (EIS). The effect of pH of buffer and scan rate studies were successfully studied. Morphological changes of BCPE and Vf/CPE was studied with the help of scanning electron microscopy (SEM). The formation of Vf on CPE was also analyzed by Fourier transform infrared (FTIR) spectra. Under the optimized conditions, the limit of detection (LOD) and limit of quantification (LOQ) values of 4-aminophenol were estimated with the aid of chronoamperometry (CA) technique and was found to be 9.8 μM and 32 μM, respectively. Finally the proposed method was found to have satisfactory repeatability, reproducibility and stability results with low relative standard deviation (RSD) values.


Author(s):  
Peyman Mohammadzadeh Jahani

The electrochemical sensor was fabricated for the simultaneous determination of levodopa and cabergoline using carbon paste electrode (CPE) modified with graphene quantum dots (GQD), 2-chlorobenzoyl ferrocene (2CBF) and ionic liquid (IL). Then, the electrochemical behavior of levodopa alone and simultaneously with cabergoline at the surface of GQDs/2CBF/IL/CPE was investigated in phosphate buffer solution (PBS). Under optimal PBS, pH=7 condition, oxidation peak current has been found proportional to levodopa concentration in the range between 0.07 μM and 500.0 μM, with the limit of detection (LOD) of 0.02 μM (S/N=3). Outputs showed that at GQDs/2CBF/IL/CPE surface, the levodopa and cabergoline oxidation peaks are separated by the potential difference of 200 mV. In addition, it was found that this modified electrode possesses acceptable sensitivity, selectivity, stability and repeatability. All these properties were sufficient to allow simultaneous detection of levodopa and cabergoline in real samples at the surface of GQDs/2CBF/IL/CPE. This was supported by the successful application of this electro­chemical sensor electrode for the determination of levodopa and cabergoline in urine, serum, and cabergoline tablets.


Chemosensors ◽  
2020 ◽  
Vol 8 (1) ◽  
pp. 10 ◽  
Author(s):  
Wang ◽  
Guo ◽  
Hu ◽  
Liang ◽  
Li ◽  
...  

In this work, a label-free colorimetric assay was developed for the determination of urine glucose using smartphone ambient-light sensor (ALS). Using horseradish peroxidase—hydrogen peroxide—3,3′,5,5′-tetramethylbenzidine (HRP-H2O2-TMB) colored system, quantitative H2O2 was added to samples to-be-determined for deepest color. The presence of glucose oxidase in urine led to the formation of H2O2 and the reduction of TMBred. As a result of this, the color of the urine faded and the solution changed from deep blue to light blue. We measured the illuminance of the transmitted light by a smartphone ambient light sensor, and thereby color changes were used to calculate the content of urine glucose. After method validation, this colorimetric assay was practically applied for the determination of urine samples from diabetic patients. Good linearity was obtained in the range of 0.039–10.000 mg/mL (R2 = 0.998), and a limit of detection was 0.005 mg/mL. Our method was had high accuracy, sensitivity, simplicity, rapidity, and visualization, providing a new sensor to be potentially applicable for point-of-care detection of urine glucose.


2019 ◽  
Author(s):  
Chem Int

In this study voltammetric behaviour of secnidazole (SCZ) at 1, 4-Benzoquinone Modified Carbon Paste Electrode (1,4-BQMCPE) was investigated in Britton Robinson buffer solution using cyclic voltammetric technique. A well-defined cathodic peak was observed for the SCZ in the entire pH range. The current increases steadily with scan rate and the results indicated that the process is irreversible reduction and adsorption controlled. The number of electrons transferred and different kinetic parameters like transfer coefficient and rate constant were calculated by using cyclic voltammetry technique. Differential pulse voltammetric method has been used for the determination of SCZ content in pharmaceutical tablet. This method enabled to determine SCZ in the concentration range 1.0 × 10-8 to 4.0 × 10-4 M. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 2.13 × 10-9 and 2.85 × 10-9 respectively. The method was applied to determine the content of SCZ in different sample solutions of SCZ tablet with excellent recovery and relative standard deviation results (99.892±1.53 respectively) for spiked standard SCZ in tablet sample solutions. The selectivity of the method for SCZ was further studied in the presence of selected potential interferents such as fluconazole, azithromycin etc and confirmed the potential applicability of the developed method for the determination of SCZ in real pharmaceutical tablets.


2019 ◽  
Vol 9 (3) ◽  
pp. 408-413 ◽  
Author(s):  
Amir H. Keihan ◽  
Ghader Hosseinzadeh ◽  
Sharareh Sajjadi ◽  
Danial Ashiani ◽  
Fariba Dashtestani ◽  
...  

Background: Escherichia coli (E. coli) bacteria is one of the hazardous human pathogens. Consequently, developing the rapid and effective method for identification and quantization of E. coli is popular in biotechnological researches in recent years. Experimental: In this research, a label-free capacitance E. coli biosensor was fabricated based on immobilizing bacteriophage on the carbon paste electrode (Cp). Reduced graphene (RGr) was synthesized and used as a substrate for immobilization of bacteriophage on the Cp surface. E. coli bacteriophage was trapped in graphene modified carbon paste electrodes. The immobilization accuracy was confirmed via electrochemical techniques. The modified electrodes were applied as indicator electrodes for capacitance measurements of E. coli. Results: Through this method, E. coli was detected in a concentration range of 33×10-3 to 330×10-3 N L-1 (number of E. coli per Liter) with a correlation coefficient of 0.99 and a detection limit of 12×10-3 N L-1. Conclusion: The proposed biosensor has a fast response time of about 5 s and good selectivity over other bacteria.


Author(s):  
Ashraf Mahmoud ◽  
Mater Mahnashi ◽  
Samer Abu-Alrub ◽  
Saad Kahatani ◽  
Mohamed El-Wekil

Abstract An innovative and reliable electrochemical sensor was proposed for simple, sensitive and selective determination of F- ions. The sensor is based on the fabrication of porous and electroactive Fe-based metal organic frameworks [MIL-101(Fe)]. It was blended with graphite powder and liquid paraffin oil to from carbon paste electrode (CPE). The MIL-101(Fe)@CPE was characterized using different techniques such as scanning electron microscope, powder X-ray diffraction spectroscopy, Fourier transform infrared spectroscopy, energy dispersive X-ray, cyclic voltammetry, electrochemical impedance spectroscopy, differential pulse voltammetry. The MIL-101(Fe)@CPE exhibited two redox peaks (anodic and cathodic) corresponding to Fe3+ and Fe2+, respectively. The determination of F- ions based on the formation of a stable fluoroferric complex with Fe3+/ Fe2+, decreasing the currents of redox species. It was found that the anodic peak current (Ipa) is linearly proportional to the concentration of F- in the range of 0.67-130 µM with a limit of detection (S/N=3) of 0.201 µM. The electrode exhibited good selectivity towards F- detection with no significant interferences from common anions. The as-fabricated sensor was applied for the determination of F- in environmental water samples with recoveries % and RSDs % in the range of 98.1-102.4 % and 2.4-3.7 %, respectively.