scholarly journals Speed Calibration and Traceability for Train-Borne 24 GHz Continuous-Wave Doppler Radar Sensor

Sensors ◽  
2020 ◽  
Vol 20 (4) ◽  
pp. 1230
Author(s):  
Lei Du ◽  
Qiao Sun ◽  
Jie Bai ◽  
Xiaolei Wang ◽  
Tianqi Xu

The 24 GHz continuous-wave (CW) Doppler radar sensor (DRS) is widely used for measuring the instantaneous speed of moving objects by using a non-contact approach, and has begun to be used in train-borne movable speed measurements in recent years in China because of its advanced performance. The architecture and working principle of train-borne DRSs with different structures including single-channel DRSs used for freight train speed measurements in railway freight dedicated lines and dual-channel DRSs used for speed measurements of high-speed and urban rail trains in railway passenger dedicated lines, are first introduced. Then, the disadvantages of two traditional speed calibration methods for train-borne DRS are described, and a new speed calibration method based on the Doppler shift signal simulation by imposing a signal modulation on the incident CW microwave signal is proposed. A 24 GHz CW radar target simulation system for a train-borne DRS was specifically realized to verify the proposed speed calibration method for a train-borne DRS, and traceability and performance evaluation on simulated speed were taken into account. The simulated speed range of the simulation system was up to (5~500) km/h when the simulated incident angle range was within the range of (45 ± 8)°, and the maximum permissible error (MPE) of the simulated speed was ±0.05 km/h. Finally, the calibration and uncertainty evaluation results of two typical train-borne dual-channel DRS samples validated the effectiveness and feasibility of the proposed speed calibration approach for a train-borne DRS with full range in the laboratory as well as in the field.

Electronics ◽  
2019 ◽  
Vol 8 (8) ◽  
pp. 855 ◽  
Author(s):  
Park ◽  
Jeong ◽  
Lee ◽  
Oh ◽  
Yang

The authors wish to make the following corrections to the published paper [...]


2019 ◽  
Vol 11 (10) ◽  
pp. 1237 ◽  
Author(s):  
Hyunjae Lee ◽  
Byung-Hyun Kim ◽  
Jin-Kwan Park ◽  
Jong-Gwan Yook

A novel non-contact vital-sign sensing algorithm for use in cases of multiple subjects is proposed. The approach uses a 24 GHz frequency-modulated continuous-wave Doppler radar with the parametric spectral estimation method. Doppler processing and spectral estimation are concurrently implemented to detect vital signs from more than one subject, revealing excellent results. The parametric spectral estimation method is utilized to clearly identify multiple targets, making it possible to distinguish multiple targets located less than 40 cm apart, which is beyond the limit of the theoretical range resolution. Fourier transformation is used to extract phase information, and the result is combined with the spectral estimation result. To eliminate mutual interference, the range integration is performed when combining the range and phase information. By considering breathing and heartbeat periodicity, the proposed algorithm can accurately extract vital signs in real time by applying an auto-regressive algorithm. The capability of a contactless and unobtrusive vital sign measurement with a millimeter wave radar system has innumerable applications, such as remote patient monitoring, emergency surveillance, and personal health care.


Resuscitation ◽  
2015 ◽  
Vol 96 ◽  
pp. 53-54
Author(s):  
Jens Muehlsteff ◽  
Ralph Wijshoff ◽  
Marek Bartula ◽  
Marc Fuller ◽  
Dawn B. Jorgenson ◽  
...  

Electronics ◽  
2019 ◽  
Vol 8 (5) ◽  
pp. 561 ◽  
Author(s):  
Jae-Hyun Park ◽  
Yeo-Jin Jeong ◽  
Ga-Eun Lee ◽  
Jun-Taek Oh ◽  
Jong-Ryul Yang

A miniaturized continuous-wave Doppler radar sensor operating at 915 MHz to remotely detect both respiration and heart rate (beats per minute) is presented. The proposed radar sensor comprises a front-end module including an implemented complementary metal-oxide semiconductor low-noise amplifier (LNA) and fractal-slot patch antennas, whose area was reduced by 15.2%. The two-stage inverter-based LNA was designed with an interstage capacitor and a feedback resistor to acquire ultrawide bandwidth. Two operating frequencies, 915 MHz and 2.45 GHz, were analyzed with regard to path loss for efficient operation because frequency affects detection sensitivity, reflected signal power from the human body, and measurement distance in a far-field condition. Path-loss calculation based on the simplified layer model indicates that the reflected power of the 915 MHz radar could be higher than that of the 2.45 GHz radar. The implemented radar front-end module excluding the LNA occupies 35 × 55 mm2. Vital signs were obtained via a fast Fourier transform and digital filtering using raw signals. In an experiment with six subjects, the respiration and heart rate obtained at 0.8 m using the proposed radar sensor exhibited mean accuracies of 99.4% and 97.6% with respect to commercialized reference sensors, respectively.


IEEE Access ◽  
2019 ◽  
Vol 7 ◽  
pp. 74721-74733 ◽  
Author(s):  
Vladimir L. Petrovic ◽  
Milica M. Jankovic ◽  
Anita V. Lupsic ◽  
Veljko R. Mihajlovic ◽  
Jelena S. Popovic-Bozovic

2013 ◽  
Vol 5 (3) ◽  
pp. 309-317 ◽  
Author(s):  
Christian Bredendiek ◽  
Nils Pohl ◽  
Timo Jaeschke ◽  
Sven Thomas ◽  
Klaus Aufinger ◽  
...  

In this paper a monostatic frequency-modulated continuous-wave (FMCW) radar system around a center frequency of 24 GHz with a wide tuning range of 8 GHz (≈33%) is presented. It is based on a fully integrated single-channel SiGe transceiver chip. The chip architecture consists of a fundamental VCO, a receive mixer, a divider chain, and coupling/matching networks. All circuits, except for the divider, are designed with the extensive use of on-chip monolithic integrated spiral inductors. The chip is fabricated in a SiGe bipolar production technology which offers an fT of 170 GHz and fmax of 250 GHz. The phase noise at 1 MHz offset is better than −100 dBc/Hz over the full-tuning range of 8 GHz and a phase noise of better than −111 dBc/Hz is achieved at 27 GHz. The peak output power of the chip is −1 dBm while the receive mixer offers a 1 dBm input referred compression point to keep it from being saturated. The chip has a power consumption of 245 mW and uses an area of 1.51 mm2. The FMCW radar system achieves a power consumption below 1.6 W. Owing to the high stability of the sensor, high accuracy mesaurements with a range error <±250 µm were achieved. The standard deviation between repeated measurements of the same target is 0.6 µm and the spatial resolution is 28 mm.


Sign in / Sign up

Export Citation Format

Share Document