scholarly journals Laboratory Calibration and Performance Evaluation of Low-Cost Capacitive and Very Low-Cost Resistive Soil Moisture Sensors

Sensors ◽  
2020 ◽  
Vol 20 (2) ◽  
pp. 363 ◽  
Author(s):  
Soham Adla ◽  
Neeraj Kumar Rai ◽  
Sri Harsha Karumanchi ◽  
Shivam Tripathi ◽  
Markus Disse ◽  
...  

Soil volumetric water content ( V W C ) is a vital parameter to understand several ecohydrological and environmental processes. Its cost-effective measurement can potentially drive various technological tools to promote data-driven sustainable agriculture through supplemental irrigation solutions, the lack of which has contributed to severe agricultural distress, particularly for smallholder farmers. The cost of commercially available V W C sensors varies over four orders of magnitude. A laboratory study characterizing and testing sensors from this wide range of cost categories, which is a prerequisite to explore their applicability for irrigation management, has not been conducted. Within this context, two low-cost capacitive sensors—SMEC300 and SM100—manufactured by Spectrum Technologies Inc. (Aurora, IL, USA), and two very low-cost resistive sensors—the Soil Hygrometer Detection Module Soil Moisture Sensor (YL100) by Electronicfans and the Generic Soil Moisture Sensor Module (YL69) by KitsGuru—were tested for performance in laboratory conditions. Each sensor was calibrated in different repacked soils, and tested to evaluate accuracy, precision and sensitivity to variations in temperature and salinity. The capacitive sensors were additionally tested for their performance in liquids of known dielectric constants, and a comparative analysis of the calibration equations developed in-house and provided by the manufacturer was carried out. The value for money of the sensors is reflected in their precision performance, i.e., the precision performance largely follows sensor costs. The other aspects of sensor performance do not necessarily follow sensor costs. The low-cost capacitive sensors were more accurate than manufacturer specifications, and could match the performance of the secondary standard sensor, after soil specific calibration. SMEC300 is accurate ( M A E , R M S E , and R A E of 2.12%, 2.88% and 0.28 respectively), precise, and performed well considering its price as well as multi-purpose sensing capabilities. The less-expensive SM100 sensor had a better accuracy ( M A E , R M S E , and R A E of 1.67%, 2.36% and 0.21 respectively) but poorer precision than the SMEC300. However, it was established as a robust, field ready, low-cost sensor due to its more consistent performance in soils (particularly the field soil) and superior performance in fluids. Both the capacitive sensors responded reasonably to variations in temperature and salinity conditions. Though the resistive sensors were less accurate and precise compared to the capacitive sensors, they performed well considering their cost category. The YL100 was more accurate ( M A E , R M S E , and R A E of 3.51%, 5.21% and 0.37 respectively) than YL69 ( M A E , R M S E , and R A E of 4.13%, 5.54%, and 0.41, respectively). However, YL69 outperformed YL100 in terms of precision, and response to temperature and salinity variations, to emerge as a more robust resistive sensor. These very low-cost sensors may be used in combination with more accurate sensors to better characterize the spatiotemporal variability of field scale soil moisture. The laboratory characterization conducted in this study is a prerequisite to estimate the effect of low- and very low-cost sensor measurements on the efficiency of soil moisture based irrigation scheduling systems.

2019 ◽  
Vol 14 (No. 4) ◽  
pp. 195-199 ◽  
Author(s):  
Iftikhar Ahmed Saeed ◽  
Minjuan Wang ◽  
Yanzhao Ren ◽  
Qinglan Shi ◽  
Muhammad Hammad Malik ◽  
...  

Soil moisture (SM) varies greatly in the soil profile. We developed a low-cost sensor for SM monitoring at three vertical depths. The sensor function was based on dielectric theory to monitor SM. Three linear calibration models were established using different soils. The sensor for each depth showed acceptable statistics of validations. The linear fit coefficient of determination (R<sup>2</sup>) ranged from 0.95 to 0.99. Root mean square error (RMSE) ranged from 1.35 to 4.30. The sensor performed consistently for at least 4 months, and is suitable for continuous monitoring of in situ SM and irrigation scheduling.


Sensors ◽  
2021 ◽  
Vol 21 (16) ◽  
pp. 5387
Author(s):  
Abdelaziz M. Okasha ◽  
Hasnaa G. Ibrahim ◽  
Adel H. Elmetwalli ◽  
Khaled Mohamed Khedher ◽  
Zaher Mundher Yaseen ◽  
...  

Precise and quick estimates of soil moisture content for the purpose of irrigation scheduling are fundamentally important. They can be accomplished through the continuous monitoring of moisture content in the root zone area, which can be accomplished through automatic soil moisture sensors. Commercial soil moisture sensors are still expensive to be used by famers, particularly in developing countries, such as Egypt. This research aimed to design and calibrate a locally manufactured low-cost soil moisture sensor attached to a smart monitoring unit operated by Solar Photo Voltaic Cells (SPVC). The designed sensor was evaluated on clay textured soils in both lab and controlled greenhouse environments. The calibration results demonstrated a strong correlation between sensor readings and soil volumetric water content (θV). Higher soil moisture content was associated with decreased sensor output voltage with an average determination coefficient (R2) of 0.967 and a root-mean-square error (RMSE) of 0.014. A sensor-to-sensor variability test was performed yielding a 0.045 coefficient of variation. The results obtained from the real conditions demonstrated that the monitoring system for real-time sensing of soil moisture and environmental conditions inside the greenhouse could be a robust, accurate, and cost-effective tool for irrigation management.


Agriculture ◽  
2019 ◽  
Vol 9 (7) ◽  
pp. 141 ◽  
Author(s):  
Ekanayaka Achchillage Ayesha Dilrukshi Nagahage ◽  
Isura Sumeda Priyadarshana Nagahage ◽  
Takeshi Fujino

Readily available moisture in the root zone is very important for optimum plant growth. The available techniques to determine soil moisture content have practical limitations owing to their high cost, dependence on labor, and time consumption. We have developed a prototype for automated soil moisture monitoring using a low-cost capacitive soil moisture sensor (SKU:SEN0193) for data acquisition, connected to the internet. A soil-specific calibration was performed to integrate the sensor with the automated soil moisture monitoring system. The accuracy of the soil moisture measurements was compared with those of a gravimetric method and a well-established soil moisture sensor (SM-200, Delta-T Devices Ltd, Cambridge, UK). The root-mean-square error (RMSE) of the soil water contents obtained with the SKU:SEN0193 sensor function, the SM-200 manufacturer’s function, and the SM-200 soil-specific calibration function were 0.09, 0.07, and 0.06 cm3 cm−3, for samples in the dry to saturated range, and 0.05, 0.08, and 0.03 cm3 cm−3, for samples in the field capacity range. The repeatability of the measurements recorded with the developed calibration function support the potential use of the SKU:SEN0193 sensor to minimize the risk of soil moisture stress or excess water application.


2007 ◽  
Vol 47 (2) ◽  
pp. 215 ◽  
Author(s):  
S. M. Pathan ◽  
L. Barton ◽  
T. D. Colmer

This study evaluated water application rates, leaching and quality of couch grass (Cynodon dactylon cv. Wintergreen) under a soil moisture sensor-controlled irrigation system, compared with plots under conventional irrigation scheduling as recommended for domestic lawns in Perth, Western Australia by the State’s water supplier. The cumulative volume of water applied during summer to the field plots of turfgrass with the sensor-controlled system was 25% less than that applied to plots with conventional irrigation scheduling. During 154 days over summer and autumn, about 4% of the applied water drained from lysimeters in sensor-controlled plots, and about 16% drained from lysimeters in plots with conventional irrigation scheduling. Even though losses of mineral nitrogen via leaching were extremely small (representing only 1.1% of the total nitrogen applied to conventionally irrigated plots), losses were significantly lower in the sensor-controlled plots. Total clippings produced were 18% lower in sensor-controlled plots. Turfgrass colour in sensor-controlled plots was reduced during summer, but colour remained acceptable under both treatments. The soil moisture sensor-controlled irrigation system enabled automatic implementation of irrigation events to match turfgrass water requirements.


Sensors ◽  
2019 ◽  
Vol 19 (3) ◽  
pp. 491 ◽  
Author(s):  
Juan González-Teruel ◽  
Roque Torres-Sánchez ◽  
Pedro Blaya-Ros ◽  
Ana Toledo-Moreo ◽  
Manuel Jiménez-Buendía ◽  
...  

Water is the main limiting factor in agricultural production as well as a scarce resource that needs to be optimized. The measurement of soil water with sensors is an efficient way for optimal irrigation management. However, commercial sensors are still too expensive for most farmers. This paper presents the design, development and calibration of a new capacitive low-cost soil moisture sensor that incorporates SDI-12 communication, allowing one to select the calibration equation for different soils. The sensor was calibrated in three different soils and its variability and accuracy were evaluated. Lower but cost-compensated accuracy was observed in comparing it with commercial sensors. Field tests have demonstrated the temperature influence on the sensor and its capability to efficiently detect irrigation and rainfall events.


2016 ◽  
Vol 8 (4) ◽  
pp. 1959-1965 ◽  
Author(s):  
Jitendra Kumar ◽  
Neelam Patel ◽  
T. B. S. Rajput

Soil moisture sensor is an instrument for quick measurements of soil moisture content in the crop root zone on real time basis. The main objective of this research was development and evaluation of an indigenous sensor for precise irrigation scheduling. The various parts of sensor developed were ceramic cup, acrylic pipe, level sensor, tee, reducer, gland, cork, and end cap. The designed system was successfully tested on okra crop and calibrated with frequency domain reflectometry (FDR) by three methods of irrigation, i.e. check basin, furrow and drip, respectively. The average depth of water depletion in modified tensiometer by these methods was 27 to 35 cm at 50% management allowable depletion (MAD) of field capacity. This depth was useful for the level sensor to be installed inside modified tensiometer for real time irrigation scheduling. The correlation coefficient (R2) between soil moisture content obtained from the developed sensor and FDR was 0.963. Sensor network was integrated with global system for mobile communication (GSM), short message service (SMS) and drip head work to develop an automated irrigation system. This would enable farmers to effectively monitor and control water application in the field by sending command through SMS and receiving pumping status through the mobile phone.