scholarly journals Robust and Accurate Hand–Eye Calibration Method Based on Schur Matric Decomposition

Sensors ◽  
2019 ◽  
Vol 19 (20) ◽  
pp. 4490
Author(s):  
Liu ◽  
Wu ◽  
Li

To improve the accuracy and robustness of hand–eye calibration, a hand–eye calibration method based on Schur matric decomposition is proposed in this paper. The accuracy of these methods strongly depends on the quality of observation data. Therefore, preprocessing observation data is essential. As with traditional two-step hand–eye calibration methods, we first solve the rotation parameters and then the translation vector can be immediately determined. A general solution was obtained from one observation through Schur matric decomposition and then the degrees of freedom were decreased from three to two. Observation data preprocessing is one of the basic unresolved problems with hand–eye calibration methods. A discriminant equation to delete outliers was deduced based on Schur matric decomposition. Finally, the basic problem of observation data preprocessing was solved using outlier detection, which significantly improved robustness. The proposed method was validated by both simulations and experiments. The results show that the prediction error of rotation and translation was 0.06 arcmin and 1.01 mm respectively, and the proposed method performed much better in outlier detection. A minimal configuration for the unique solution was proven from a new perspective.

Author(s):  
Mourad Miled ◽  
Bahman Soheilian ◽  
Emmanuel Habets ◽  
Bruno Vallet

This paper proposes an hybrid online calibration method for a laser scanner mounted on a mobile platform also equipped with an imaging system. The method relies on finding the calibration parameters that best align the acquired points cloud to the images. The quality of this intermodal alignment is measured by Mutual information between image luminance and points reflectance. The main advantage and motivation is ensuring pixel accurate alignment of images and point clouds acquired simultaneously, but it is also much more flexible than traditional laser calibration methods.


2006 ◽  
Vol 23 (7) ◽  
pp. 927-935 ◽  
Author(s):  
Margaret M. Wonsick ◽  
Rachel T. Pinker ◽  
Wen Meng ◽  
Louis Nguyen

Abstract Parameters derived from satellite observations depend on the quality of the calibration method applied to the raw satellite radiance measurements. This study investigates the sensitivity of absolute reflectance, derived cloud cover, and estimated surface shortwave (SW) downward fluxes to two different calibration methods for the visible sensor aboard the eighth Geostationary Operational Environmental Satellite (GOES-8). The first method was developed at NOAA's National Environmental Satellite, Data, and Information Service (NESDIS), and the second at the NASA Langley Research Center. Differences in visible reflectance ranged from −0.5% to 3%. The average difference in monthly mean cloud amount was ∼3%, and the average difference in monthly mean shortwave downward flux was 5 W m−2. Differences in bias and rms of the SW fluxes when evaluated against ground station measurements were less than 3 W m−2. Neither calibration method was shown to consistently outperform the other. This evaluation yields an estimate of the errors in fluxes that can be attributed to calibration.


2011 ◽  
Vol 58-60 ◽  
pp. 1148-1153 ◽  
Author(s):  
Jia Long ◽  
Xiu Mei Zhang ◽  
Long Zhao

A fast and simple calibration method based on vanishing point is carried out to overcome the disadvantage of low efficiency and operation problems which the traditional calibration methods based on standard calibration field has. Focal length and rotation matrix can be calculated by the information of two sets of parallel lines, then translation vector is obtained by the space length and image coordinates of a straight line derived from the origin. The results of experiment indicate the simplicity of this method. At the same time the efficiency is improved with satisfying calibration accuracy in practical application.


Author(s):  
Mourad Miled ◽  
Bahman Soheilian ◽  
Emmanuel Habets ◽  
Bruno Vallet

This paper proposes an hybrid online calibration method for a laser scanner mounted on a mobile platform also equipped with an imaging system. The method relies on finding the calibration parameters that best align the acquired points cloud to the images. The quality of this intermodal alignment is measured by Mutual information between image luminance and points reflectance. The main advantage and motivation is ensuring pixel accurate alignment of images and point clouds acquired simultaneously, but it is also much more flexible than traditional laser calibration methods.


2020 ◽  
Vol 34 (8) ◽  
pp. 938-948
Author(s):  
Sarah McKenna ◽  
Alison Hassall ◽  
Richard O'Kearney ◽  
Dave Pasalich

Author(s):  
Yudong Qiu ◽  
Daniel Smith ◽  
Chaya Stern ◽  
mudong feng ◽  
Lee-Ping Wang

<div>The parameterization of torsional / dihedral angle potential energy terms is a crucial part of developing molecular mechanics force fields.</div><div>Quantum mechanical (QM) methods are often used to provide samples of the potential energy surface (PES) for fitting the empirical parameters in these force field terms.</div><div>To ensure that the sampled molecular configurations are thermodynamically feasible, constrained QM geometry optimizations are typically carried out, which relax the orthogonal degrees of freedom while fixing the target torsion angle(s) on a grid of values.</div><div>However, the quality of results and computational cost are affected by various factors on a non-trivial PES, such as dependence on the chosen scan direction and the lack of efficient approaches to integrate results started from multiple initial guesses.</div><div>In this paper we propose a systematic and versatile workflow called \textit{TorsionDrive} to generate energy-minimized structures on a grid of torsion constraints by means of a recursive wavefront propagation algorithm, which resolves the deficiencies of conventional scanning approaches and generates higher quality QM data for force field development.</div><div>The capabilities of our method are presented for multi-dimensional scans and multiple initial guess structures, and an integration with the MolSSI QCArchive distributed computing ecosystem is described.</div><div>The method is implemented in an open-source software package that is compatible with many QM software packages and energy minimization codes.</div>


2012 ◽  
Vol 6 (1) ◽  
pp. 5-15 ◽  
Author(s):  
Michael R Dawson ◽  
Farbod Fahimi ◽  
Jason P Carey

The objective of above-elbow myoelectric prostheses is to reestablish the functionality of missing limbs and increase the quality of life of amputees. By using electromyography (EMG) electrodes attached to the surface of the skin, amputees are able to control motors in myoelectric prostheses by voluntarily contracting the muscles of their residual limb. This work describes the development of an inexpensive myoelectric training tool (MTT) designed to help upper limb amputees learn how to use myoelectric technology in advance of receiving their actual myoelectric prosthesis. The training tool consists of a physical and simulated robotic arm, signal acquisition hardware, controller software, and a graphical user interface. The MTT improves over earlier training systems by allowing a targeted muscle reinnervation (TMR) patient to control up to two degrees of freedom simultaneously. The training tool has also been designed to function as a research prototype for novel myoelectric controllers. A preliminary experiment was performed in order to evaluate the effectiveness of the MTT as a learning tool and to identify any issues with the system. Five able-bodied participants performed a motor-learning task using the EMG controlled robotic arm with the goal of moving five balls from one box to another as quickly as possible. The results indicate that the subjects improved their skill in myoelectric control over the course of the trials. A usability survey was administered to the subjects after their trials. Results from the survey showed that the shoulder degree of freedom was the most difficult to control.


Healthcare ◽  
2021 ◽  
Vol 9 (6) ◽  
pp. 656
Author(s):  
Vladimir Bulatnikov ◽  
Cristinel Petrişor Constantin

This paper aims at finding the most dominant ideas about the marketing of healthcare systems highlighted in the mainstream literature, with a focus on Russia and Romania. To reach this goal, a systematic analysis of literature was conducted and various competitive advantages and disadvantages of the medical models that require special attention from the governments are considered. In this respect we examined 106 papers published during 2006 to 2020 found on four scientific databases. They were selected using inclusion and exclusion criteria according to PRISMA methodology. The main findings of the research consist of the opportunity to use marketing tools in order to improve the quality of healthcare systems in the named countries. Thus, using market orientation, the managers of healthcare systems could stimulate the innovation, the efficiency of funds allocation and the quality of medical services. The results will lead to a better quality of population life and to an increasing of life expectancy. As this paper reviews some articles from Russian literature, it can add a new perspective to the topic. These outcomes have implications for government, business environment, and academia, which should cooperate in order to develop the healthcare system using marketing strategies.


Measurement ◽  
2021 ◽  
Vol 174 ◽  
pp. 109067
Author(s):  
Zhi-Feng Lou ◽  
Li Liu ◽  
Ji-Yun Zhang ◽  
Kuang-chao Fan ◽  
Xiao-Dong Wang

Sensors ◽  
2021 ◽  
Vol 21 (3) ◽  
pp. 765
Author(s):  
Hugo Álvarez ◽  
Marcos Alonso ◽  
Jairo R. Sánchez ◽  
Alberto Izaguirre

This paper describes a method for calibrating multi camera and multi laser 3D triangulation systems, particularly for those using Scheimpflug adapters. Under this configuration, the focus plane of the camera is located at the laser plane, making it difficult to use traditional calibration methods, such as chessboard pattern-based strategies. Our method uses a conical calibration object whose intersections with the laser planes generate stepped line patterns that can be used to calculate the camera-laser homographies. The calibration object has been designed to calibrate scanners for revolving surfaces, but it can be easily extended to linear setups. The experiments carried out show that the proposed system has a precision of 0.1 mm.


Sign in / Sign up

Export Citation Format

Share Document