scholarly journals Evaluation of Bipolar, Tripolar, and Quadripolar Laplacian Estimates of Electrocardiogram via Concentric Ring Electrodes

Sensors ◽  
2019 ◽  
Vol 19 (17) ◽  
pp. 3780 ◽  
Author(s):  
Javier Garcia-Casado ◽  
Yiyao Ye-Lin ◽  
Gema Prats-Boluda ◽  
Oleksandr Makeyev

Surface Laplacian estimates via concentric ring electrodes (CREs) have proven to enhance spatial resolution compared to conventional disc electrodes, which is of great importance for P-wave analysis. In this study, Laplacian estimates for traditional bipolar configuration (BC), two tripolar configurations with linearly decreasing and increasing inter-ring distances (TCLDIRD and TCLIIRD, respectively), and quadripolar configuration (QC) were obtained from cardiac recordings with pentapolar CREs placed at CMV1 and CMV2 positions. Normalized P-wave amplitude (NAP) was computed to assess the contrast to study atrial activity. Signals were of good quality (20–30 dB). Atrial activity was more emphasized at CMV1 (NAP ≃ 0.19–0.24) compared to CMV2 (NAP ≃ 0.08–0.10). Enhanced spatial resolution of TCLIIRD and QC resulted in higher NAP values than BC and TCLDIRD. Comparison with simultaneous standard 12-lead ECG proved that Laplacian estimates at CMV1 outperformed all the limb and chest standard leads in the contrast to study P-waves. Clinical recordings with CRE at this position could allow more detailed observation of atrial activity and facilitate the diagnosis of associated pathologies. Furthermore, such recordings would not require additional electrodes on limbs and could be performed wirelessly, so it should also be suitable for ambulatory monitoring, for example, using cardiac Holter monitors.

Diagnostics ◽  
2021 ◽  
Vol 11 (9) ◽  
pp. 1694
Author(s):  
Dimitrios Tachmatzidis ◽  
Dimitrios Filos ◽  
Ioanna Chouvarda ◽  
Anastasios Tsarouchas ◽  
Dimitrios Mouselimis ◽  
...  

Early identification of patients at risk for paroxysmal atrial fibrillation (PAF) is essential to attain optimal treatment and a favorable prognosis. We compared the performance of a beat-to-beat (B2B) P-wave analysis with that of standard P-wave indices (SPWIs) in identifying patients prone to PAF. To this end, 12-lead ECG and 10 min vectorcardiogram (VCG) recordings were obtained from 33 consecutive, antiarrhythmic therapy naïve patients, with a short history of low burden PAF, and from 56 age- and sex-matched individuals with no AF history. For both groups, SPWIs were calculated, while the VCG recordings were analyzed on a B2B basis, and the P-waves were classified to a primary or secondary morphology. Wavelet transform was used to further analyze P-wave signals of main morphology. Univariate analysis revealed that none of the SPWIs performed acceptably in PAF detection, while five B2B features reached an AUC above 0.7. Moreover, multivariate logistic regression analysis was used to develop two classifiers—one based on B2B analysis derived features and one using only SPWIs. The B2B classifier was found to be superior to SPWIs classifier; B2B AUC: 0.849 (0.754–0.917) vs. SPWIs AUC: 0.721 (0.613–0.813), p value: 0.041. Therefore, in the studied population, the proposed B2B P-wave analysis outperforms SPWIs in detecting patients with PAF while in sinus rhythm. This can be used in further clinical trials regarding the prognosis of such patients.


Geophysics ◽  
1991 ◽  
Vol 56 (6) ◽  
pp. 859-862 ◽  
Author(s):  
Robert R. Stewart

Multicomponent seismic recordings are currently being analyzed in an attempt to improve conventional P‐wave sections and to find and use rock properties associated with shear waves (e.g. Dohr, 1985; Danbom and Dominico, 1986). Mode‐converted (P-SV) waves hold a special interest for several reasons: They are generated by conventional P‐wave sources and have only a one‐way travel path as a shear wave through the typically low velocity and attenuative near surface. For a given frequency, they will have a shorter wavelength than the original P wave, and thus offer higher spatial resolution; this has been observed in several vertical seismic profiling (VSP) cases (e.g., Geis et al., 1990). However, for surface seismic data, converted waves are often found to be of lower frequency than P-P waves (e.g., Eaton et al., 1991).


2021 ◽  
Vol 42 (Supplement_1) ◽  
Author(s):  
D Tachmatzidis ◽  
D Filos ◽  
A Tsarouchas ◽  
D Mouselimis ◽  
C Bakogiannis ◽  
...  

Abstract Introduction Atrial fibrillation (AF) is the most common arrhythmia and is associated with high risk of morbidity and mortality. In many patients, AF is of episodic character (paroxysmal AF – PAF), which makes the identification of these patients during sinus rhythm (SR) challenging. Purpose The aim of the present study is to compare the performance of beat-to-beat P-wave analysis with P-wave indices used as predictors of PAF, such as P-wave duration, area, voltage, axis, terminal force in V1, inter-atrial block or orthogonal type, in identifying patients with history of PAF during sinus rhythm. Methods Standard 12-lead ECG and 10-minute orthogonal ECG recordings were obtained from 40 consecutive patients with short history of PAF under no antiarrhythmic medication and 60 age- and sex- matched healthy controls. The P-waves on the 10-minute recordings were analyzed on a beat-to-beat basis and classified as belonging to a primary or secondary morphology according to previous study. Wavelet transform used to further analyze P-wave orthogonal signals of main morphology on a beat-to-beat basis. Results 38 out of 327 studied features were found to differ significantly among the two groups. These features were tested for their diagnostic ability and receiver operating characteristic curves were ploted. Only 3 of them performed adequetly, with an area under curve (AUC) above 0.65; Two of them came from morphology analysis (percentage of beats following main morphology in axis X and Y) and one from wavelet analysis (max energy in high frequency zone -Y axis). Among standard P-wave indices, P-wave area in lead II was the one with the highest AUC (0.64). Conclusion Novel indices derived from beat-to-beat analysis outperform stadard P-wave markers in identifying patients with PAF history during sinus rhythm. FUNDunding Acknowledgement Type of funding sources: None. ROC curves of most significant features AUC characteristics of P-wave indices


1975 ◽  
Vol 65 (6) ◽  
pp. 1667-1680
Author(s):  
Ronald W. Ward ◽  
Keiiti Aki

abstract A wave theory method is used to determine the effect of a sinking lithospheric slab on short-period and long-period waves. We consider a simplified model of the lithospheric slab with a 10 per cent velocity contrast and compute both short-period and long-period theoretical seismograms from a P-wave source located in or near the slab. For this model, the ray-theoretical amplitude agrees quite well with the short-period amplitude. In the ray-theoretical shadow zone the long-period seismograms (15- to 25-sec dominant period) typically have amplitudes 50 per cent (or greater) of the direct P-wave amplitude and exhibit wave-form broadening. Similar wave-form broadening has been attributed to the dynamics of earthquake faulting. The effect of the lithosphere on long-period waves from nearby sources must be taken into account in studies which utilize the observed variation in wave-form broadening to infer earthquake source dynamics.


EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
D Tachmatzidis ◽  
D Filos ◽  
I Chouvarda ◽  
A Tsarouchas ◽  
D Mouselimis ◽  
...  

Abstract Background A manually beat-to-beat P-wave analysis has previously revealed the existence of multiple P-wave morphologies in patients with paroxysmal Atrial Fibrillation (AF) while on sinus rhythm, distinguishing them from healthy, AF free patients. Purpose The aim of this study was to investigate the effectiveness of an Automated Beat Exclusion algorithm (ABE) that excludes noisy or ectopic beats, replacing manual beat evaluation during beat-to-beat P-wave analysis, by assessing its effect on inter-rater variability and reproducibility. Methods Beat-to-beat P-wave morphology analysis was performed on 34 ten-minute ECG recordings of patients with a history of AF. Each recording was analyzed independently by two clinical experts for a total of four analysis runs; once with ABE and once again with the manual exclusion of ineligible beats. The inter-rater variability and reproducibility of the analysis with and without ABE were assessed by comparing the agreement of analysis runs with respect to secondary morphology detection, primary morphology ECG template and the percentage of both, as these aspects have been previously used to discriminate PAF patients from controls. Results Comparing ABE to manual exclusion in detecting secondary P-wave morphologies displayed substantial (Cohen"s k = 0.69) to almost perfect (k = 0.82) agreement. Area difference among auto and manually calculated main morphology templates was in every case <5% (p < 0.01) and the correlation coefficient was >0.99 (p < 0.01). Finally, the percentages of beats classified to the primary or secondary morphology per recording by each analysis were strongly correlated, for both main and secondary P-wave morphologies, ranging from ρ=0.756 to ρ=0.940 (picture) Conclusion The use of the ABE algorithm does not diminish inter-rater variability and reproducibility of the analysis. The primary and secondary P-wave morphologies produced by all analyses were similar, both in terms of their template and their frequency. Based on the results of this study, the ABE algorithm incorporated in the beat-to-beat P-wave morphology analysis drastically reduces operator workload without influencing the quality of the analysis. Abstract Figure.


Geophysics ◽  
2021 ◽  
Vol 86 (3) ◽  
pp. T155-T164
Author(s):  
Wanting Hou ◽  
Li-Yun Fu ◽  
José M. Carcione ◽  
Zhiwei Wang ◽  
Jia Wei

Thermoelasticity is important in seismic propagation due to the effects related to wave attenuation and velocity dispersion. We have applied a novel finite-difference (FD) solver of the Lord-Shulman thermoelasticity equations to compute synthetic seismograms that include the effects of the thermal properties (expansion coefficient, thermal conductivity, and specific heat) compared with the classic forward-modeling codes. We use a time splitting method because the presence of a slow quasistatic mode (the thermal mode) makes the differential equations stiff and unstable for explicit time-stepping methods. The spatial derivatives are computed with a rotated staggered-grid FD method, and an unsplit convolutional perfectly matched layer is used to absorb the waves at the boundaries, with an optimal performance at the grazing incidence. The stability condition of the modeling algorithm is examined. The numerical experiments illustrate the effects of the thermoelasticity properties on the attenuation of the fast P-wave (or E-wave) and the slow thermal P-wave (or T-wave). These propagation modes have characteristics similar to the fast and slow P-waves of poroelasticity, respectively. The thermal expansion coefficient has a significant effect on the velocity dispersion and attenuation of the elastic waves, and the thermal conductivity affects the relaxation time of the thermal diffusion process, with the T mode becoming wave-like at high thermal conductivities and high frequencies.