scholarly journals Is the Use of a Low-Cost sEMG Sensor Valid to Measure Muscle Fatigue?

Sensors ◽  
2019 ◽  
Vol 19 (14) ◽  
pp. 3204 ◽  
Author(s):  
Sergio Fuentes del Toro ◽  
Silvia Santos-Cuadros ◽  
Ester Olmeda ◽  
Carolina Álvarez-Caldas ◽  
Vicente Díaz ◽  
...  

Injuries caused by the overstraining of muscles could be prevented by means of a system which detects muscle fatigue. Most of the equipment used to detect this is usually expensive. The question then arises whether it is possible to use a low-cost surface electromyography (sEMG) system that is able to reliably detect muscle fatigue. With this main goal, the contribution of this work is the design of a low-cost sEMG system that allows assessing when fatigue appears in a muscle. To that aim, low-cost sEMG sensors, an Arduino board and a PC were used and afterwards their validity was checked by means of an experiment with 28 volunteers. This experiment collected information from volunteers, such as their level of physical activity, and invited them to perform an isometric contraction while an sEMG signal of their quadriceps was recorded by the low-cost equipment. After a wavelet filtering of the signal, root mean square (RMS), mean absolute value (MAV) and mean frequency (MNF) were chosen as representative features to evaluate fatigue. Results show how the behaviour of these parameters across time is shown in the literature coincides with past studies (RMS and MAV increase while MNF decreases when fatigue appears). Thus, this work proves the feasibility of a low-cost system to reliably detect muscle fatigue. This system could be implemented in several fields, such as sport, ergonomics, rehabilitation or human-computer interactions.

Sensors ◽  
2021 ◽  
Vol 21 (16) ◽  
pp. 5378
Author(s):  
Silvia Santos-Cuadros ◽  
Sergio Fuentes del Fuentes del Toro ◽  
Ester Olmeda ◽  
José Luis San San Román

Deaths and serious injuries caused by traffic accidents is a concerning public health problem. However, the problem can be mitigated by the Autonomous Emergency Braking (AEB) system, which can avoid the impact. The market penetration of AEB is exponentially growing, and non-impact situations are expected to become more frequent. Thus, new injury patterns must be analysed, and the neck is particularly sensitive to sudden acceleration changes. Abrupt braking would be enough to be a potential risk for cervical spine injury. There is controversy about whether or not there are differences in cervical behaviour depending on whether passengers are relaxed or contract their muscles before the imminent accident. In the present manuscript, 18 volunteers were subjected to two different levels of awareness during an emergency braking test. Cervical muscles (sternocleidomastoid and trapezius) were analysed by the sEMG signal captured by means of a low-cost system. The differences observed in the muscle response according to gender and age were notable when passengers are warned. Gender differences were more significant in the post-braking phase. When passengers were relaxed, subjects older than 35 registered higher sEMG values. Meanwhile, when passengers contract their muscles, subjects who were younger than or equal to 35 years old experienced an increment in the values of the sEMG signals.


2016 ◽  
Vol 120 (9) ◽  
pp. 1097-1103 ◽  
Author(s):  
Clovis Chabert ◽  
Pierre Bottelin ◽  
Christophe Pison ◽  
Hervé Dubouchaud

Spontaneous physical activity (SPA) can be responsible for variations of a lot of physiological parameters at the molecular, cellular, tissue, and systemic levels. It is increasingly recognized that good understanding of a large part of experimental results requires weighting them by SPA in order to reduce variability and thus to decrease the number of animals necessary to conduct a study. However, because of the high cost of this equipment, only a few laboratories are equipped with such equipment to measure the SPA of their animals. Here we present an effective, adaptable, and affordable system to measure SPA in rodents based on video acquisition of the animal in its own environment. We compared results obtained with our system to those collected at the same time with a commercial system of actimetry recording, and we found a high degree of correlation between these two approaches ( r = 0.93; P < 0.001). We also were able to detect small variations of SPA induced by a special environment like chronic hypoxia exposure (25% less spontaneous activity compared with animals in normoxia, P < 0.05) or during the circadian cycle (107% more activity during the nocturnal phase compared with the diurnal phase, P < 0.05).


2007 ◽  
Vol 40 (11) ◽  
pp. 53
Author(s):  
BRUCE K. DIXON
Keyword(s):  
Low Cost ◽  

Author(s):  
Ramin Sattari ◽  
Stephan Barcikowski ◽  
Thomas Püster ◽  
Andreas Ostendorf ◽  
Heinz Haferkamp

2020 ◽  
Vol 65 (4) ◽  
pp. 461-468
Author(s):  
Jannatul Naeem ◽  
Nur Azah Hamzaid ◽  
Amelia Wong Azman ◽  
Manfred Bijak

AbstractFunctional electrical stimulation (FES) has been used to produce force-related activities on the paralyzed muscle among spinal cord injury (SCI) individuals. Early muscle fatigue is an issue in all FES applications. If not properly monitored, overstimulation can occur, which can lead to muscle damage. A real-time mechanomyography (MMG)-based FES system was implemented on the quadriceps muscles of three individuals with SCI to generate an isometric force on both legs. Three threshold drop levels of MMG-root mean square (MMG-RMS) feature (thr50, thr60, and thr70; representing 50%, 60%, and 70% drop from initial MMG-RMS values, respectively) were used to terminate the stimulation session. The mean stimulation time increased when the MMG-RMS drop threshold increased (thr50: 22.7 s, thr60: 25.7 s, and thr70: 27.3 s), indicating longer sessions when lower performance drop was allowed. Moreover, at thr70, the torque dropped below 50% from the initial value in 14 trials, more than at thr50 and thr60. This is a clear indication of muscle fatigue detection using the MMG-RMS value. The stimulation time at thr70 was significantly longer (p = 0.013) than that at thr50. The results demonstrated that a real-time MMG-based FES monitoring system has the potential to prevent the onset of critical muscle fatigue in individuals with SCI in prolonged FES sessions.


Forests ◽  
2021 ◽  
Vol 12 (8) ◽  
pp. 1020
Author(s):  
Yanqi Dong ◽  
Guangpeng Fan ◽  
Zhiwu Zhou ◽  
Jincheng Liu ◽  
Yongguo Wang ◽  
...  

The quantitative structure model (QSM) contains the branch geometry and attributes of the tree. AdQSM is a new, accurate, and detailed tree QSM. In this paper, an automatic modeling method based on AdQSM is developed, and a low-cost technical scheme of tree structure modeling is provided, so that AdQSM can be freely used by more people. First, we used two digital cameras to collect two-dimensional (2D) photos of trees and generated three-dimensional (3D) point clouds of plot and segmented individual tree from the plot point clouds. Then a new QSM-AdQSM was used to construct tree model from point clouds of 44 trees. Finally, to verify the effectiveness of our method, the diameter at breast height (DBH), tree height, and trunk volume were derived from the reconstructed tree model. These parameters extracted from AdQSM were compared with the reference values from forest inventory. For the DBH, the relative bias (rBias), root mean square error (RMSE), and coefficient of variation of root mean square error (rRMSE) were 4.26%, 1.93 cm, and 6.60%. For the tree height, the rBias, RMSE, and rRMSE were—10.86%, 1.67 m, and 12.34%. The determination coefficient (R2) of DBH and tree height estimated by AdQSM and the reference value were 0.94 and 0.86. We used the trunk volume calculated by the allometric equation as a reference value to test the accuracy of AdQSM. The trunk volume was estimated based on AdQSM, and its bias was 0.07066 m3, rBias was 18.73%, RMSE was 0.12369 m3, rRMSE was 32.78%. To better evaluate the accuracy of QSM’s reconstruction of the trunk volume, we compared AdQSM and TreeQSM in the same dataset. The bias of the trunk volume estimated based on TreeQSM was −0.05071 m3, and the rBias was −13.44%, RMSE was 0.13267 m3, rRMSE was 35.16%. At 95% confidence interval level, the concordance correlation coefficient (CCC = 0.77) of the agreement between the estimated tree trunk volume of AdQSM and the reference value was greater than that of TreeQSM (CCC = 0.60). The significance of this research is as follows: (1) The automatic modeling method based on AdQSM is developed, which expands the application scope of AdQSM; (2) provide low-cost photogrammetric point cloud as the input data of AdQSM; (3) explore the potential of AdQSM to reconstruct forest terrestrial photogrammetric point clouds.


Sensors ◽  
2021 ◽  
Vol 21 (11) ◽  
pp. 3774
Author(s):  
Pavlos Topalidis ◽  
Cristina Florea ◽  
Esther-Sevil Eigl ◽  
Anton Kurapov ◽  
Carlos Alberto Beltran Leon ◽  
...  

The purpose of the present study was to evaluate the performance of a low-cost commercial smartwatch, the Xiaomi Mi Band (MB), in extracting physical activity and sleep-related measures and show its potential use in addressing questions that require large-scale real-time data and/or intercultural data including low-income countries. We evaluated physical activity and sleep-related measures and discussed the potential application of such devices for large-scale step and sleep data acquisition. To that end, we conducted two separate studies. In Study 1, we evaluated the performance of MB by comparing it to the GT3X (ActiGraph, wGT3X-BT), a scientific actigraph used in research, as well as subjective sleep reports. In Study 2, we distributed the MB across four countries (Austria, Germany, Cuba, and Ukraine) and investigated physical activity and sleep among these countries. The results of Study 1 indicated that MB step counts correlated highly with the scientific GT3X device, but did display biases. In addition, the MB-derived wake-up and total-sleep-times showed high agreement with subjective reports, but partly deviated from GT3X predictions. Study 2 revealed similar MB step counts across countries, but significant later wake-up and bedtimes for Ukraine than the other countries. We hope that our studies will stimulate future large-scale sensor-based physical activity and sleep research studies, including various cultures.


2021 ◽  
Vol 1826 (1) ◽  
pp. 012082
Author(s):  
G F Bassous ◽  
R F Calili ◽  
C R H Barbosa

Author(s):  
Wilver Auccahuasi ◽  
Mónica Diaz ◽  
Fernando Sernaque ◽  
Edward Flores ◽  
Justiniano Aybar ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document