scholarly journals An Advanced First Aid System Based on an Unmanned Aerial Vehicles and a Wireless Body Area Sensor Network for Elderly Persons in Outdoor Environments

Sensors ◽  
2019 ◽  
Vol 19 (13) ◽  
pp. 2955 ◽  
Author(s):  
Saif Saad Fakhrulddin ◽  
Sadik Kamel Gharghan ◽  
Ali Al-Naji ◽  
Javaan Chahl

For elderly persons, a fall can cause serious injuries such as a hip fracture or head injury. Here, an advanced first aid system is proposed for monitoring elderly patients with heart conditions that puts them at risk of falling and for providing first aid supplies using an unmanned aerial vehicle. A hybridized fall detection algorithm (FDB-HRT) is proposed based on a combination of acceleration and a heart rate threshold. Five volunteers were invited to evaluate the performance of the heartbeat sensor relative to a benchmark device, and the extracted data was validated using statistical analysis. In addition, the accuracy of fall detections and the recorded locations of fall incidents were validated. The proposed FDB-HRT algorithm was 99.16% and 99.2% accurate with regard to heart rate measurement and fall detection, respectively. In addition, the geolocation error of patient fall incidents based on a GPS module was evaluated by mean absolute error analysis for 17 different locations in three cities in Iraq. Mean absolute error was 1.08 × 10−5° and 2.01 × 10−5° for latitude and longitude data relative to data from the GPS Benchmark system. In addition, the results revealed that in urban areas, the UAV succeeded in all missions and arrived at the patient’s locations before the ambulance, with an average time savings of 105 s. Moreover, a time saving of 31.81% was achieved when using the UAV to transport a first aid kit to the patient compared to an ambulance. As a result, we can conclude that when compared to delivering first aid via ambulance, our design greatly reduces delivery time. The proposed advanced first aid system outperformed previous systems presented in the literature in terms of accuracy of heart rate measurement, fall detection, and information messages and UAV arrival time.

Sensors ◽  
2021 ◽  
Vol 21 (11) ◽  
pp. 3719
Author(s):  
Aoxin Ni ◽  
Arian Azarang ◽  
Nasser Kehtarnavaz

The interest in contactless or remote heart rate measurement has been steadily growing in healthcare and sports applications. Contactless methods involve the utilization of a video camera and image processing algorithms. Recently, deep learning methods have been used to improve the performance of conventional contactless methods for heart rate measurement. After providing a review of the related literature, a comparison of the deep learning methods whose codes are publicly available is conducted in this paper. The public domain UBFC dataset is used to compare the performance of these deep learning methods for heart rate measurement. The results obtained show that the deep learning method PhysNet generates the best heart rate measurement outcome among these methods, with a mean absolute error value of 2.57 beats per minute and a mean square error value of 7.56 beats per minute.


2021 ◽  
Vol 1831 (1) ◽  
pp. 012020
Author(s):  
Parth Kansara ◽  
Ritwik Dhar ◽  
Riddhi Shah ◽  
Devansh Mehta ◽  
Purva Raut

IEEE Access ◽  
2019 ◽  
Vol 7 ◽  
pp. 158492-158502 ◽  
Author(s):  
Pengfei Wang ◽  
Fugui Qi ◽  
Miao Liu ◽  
Fulai Liang ◽  
Huijun Xue ◽  
...  

2016 ◽  
Vol 23 (4) ◽  
pp. 579-592 ◽  
Author(s):  
Jaromir Przybyło ◽  
Eliasz Kańtoch ◽  
Mirosław Jabłoński ◽  
Piotr Augustyniak

Abstract Videoplethysmography is currently recognized as a promising noninvasive heart rate measurement method advantageous for ubiquitous monitoring of humans in natural living conditions. Although the method is considered for application in several areas including telemedicine, sports and assisted living, its dependence on lighting conditions and camera performance is still not investigated enough. In this paper we report on research of various image acquisition aspects including the lighting spectrum, frame rate and compression. In the experimental part, we recorded five video sequences in various lighting conditions (fluorescent artificial light, dim daylight, infrared light, incandescent light bulb) using a programmable frame rate camera and a pulse oximeter as the reference. For a video sequence-based heart rate measurement we implemented a pulse detection algorithm based on the power spectral density, estimated using Welch’s technique. The results showed that lighting conditions and selected video camera settings including compression and the sampling frequency influence the heart rate detection accuracy. The average heart rate error also varies from 0.35 beats per minute (bpm) for fluorescent light to 6.6 bpm for dim daylight.


Sign in / Sign up

Export Citation Format

Share Document