scholarly journals In-Situ Wireless Pressure Measurement Using Zero-Power Packaged Microwave Sensors

Sensors ◽  
2019 ◽  
Vol 19 (6) ◽  
pp. 1263 ◽  
Author(s):  
Julien Philippe ◽  
Maria De Paolis ◽  
Dominique Henry ◽  
Alexandre Rumeau ◽  
Antony Coustou ◽  
...  

This paper reports the indoor wireless measurement of pressure from zero-power (or passive) microwave (24 GHz) sensors. The sensors are packaged and allow the remote measurement of overpressure up to 2.1 bars. Their design, fabrication process and packaging are detailed. From the measurement of sensor scattering parameters, the outstanding sensitivity of 995 MHz/bar between 0.8 and 2.1 bars was achieved with the full-scale measurement range of 1.33 GHz. Moreover, the 3D radar imagery technique was applied for the remote interrogation of these sensors in electromagnetic reverberant environments. The full-scale dynamic range of 4.9 dB and the sensitivity of 4.9 dB/bar between 0.7 and 1.7 bars were achieved with radar detection in a highly reflective environment. These measurement results demonstrate for the first time the ability of the radar imagery technique to interrogate fully passive pressure sensors in electromagnetic reverberant environments.

2020 ◽  
pp. 3-8
Author(s):  
L.F. Vitushkin ◽  
F.F. Karpeshin ◽  
E.P. Krivtsov ◽  
P.P. Krolitsky ◽  
V.V. Nalivaev ◽  
...  

The State special primary acceleration measurement standard for gravimetry (GET 190-2019), its composition, principle of operation and basic metrological characteristics are presented. This standard is on the upper level of reference for free-fall acceleration measurements. Its accuracy and reliability were improved as a result of optimisation of the adjustment procedures for measurement systems and its integration within the upgraded systems, units and modern hardware components. A special attention was given to adjusting the corrections applied to measurement results with respect to procedural, physical and technical limitations. The used investigation methods made it possibled to confirm the measurement range of GET 190-2019 and to determine the contributions of main sources of errors and the total value of these errors. The measurement characteristics and GET 90-2019 were confirmed by the results obtained from measurements of the absolute value of the free fall acceleration at the gravimetrical site “Lomonosov-1” and by their collation with the data of different dates obtained from measurements by high-precision foreign and domestic gravimeters. Topicality of such measurements ensues from the requirements to handle the applied problems that need data on parameters of the Earth gravitational field, to be adequately faced. Geophysics and navigation are the main fields of application for high-precision measurements in this field.


Sensors ◽  
2019 ◽  
Vol 19 (9) ◽  
pp. 1968 ◽  
Author(s):  
Sylvie Bilent ◽  
Thi Hong Nhung Dinh ◽  
Emile Martincic ◽  
Pierre-Yves Joubert

This paper reports on the study of microporous polydimethylsiloxane (PDMS) foams as a highly deformable dielectric material used in the composition of flexible capacitive pressure sensors dedicated to wearable use. A fabrication process allowing the porosity of the foams to be adjusted was proposed and the fabricated foams were characterized. Then, elementary capacitive pressure sensors (15 × 15 mm2 square shaped electrodes) were elaborated with fabricated foams (5 mm or 10 mm thick) and were electromechanically characterized. Since the sensor responses under load are strongly non-linear, a behavioral non-linear model (first order exponential) was proposed, adjusted to the experimental data, and used to objectively estimate the sensor performances in terms of sensitivity and measurement range. The main conclusions of this study are that the porosity of the PDMS foams can be adjusted through the sugar:PDMS volume ratio and the size of sugar crystals used to fabricate the foams. Additionally, the porosity of the foams significantly modified the sensor performances. Indeed, compared to bulk PDMS sensors of the same size, the sensitivity of porous PDMS sensors could be multiplied by a factor up to 100 (the sensitivity is 0.14 %.kPa−1 for a bulk PDMS sensor and up to 13.7 %.kPa−1 for a porous PDMS sensor of the same dimensions), while the measurement range was reduced from a factor of 2 to 3 (from 594 kPa for a bulk PDMS sensor down to between 255 and 177 kPa for a PDMS foam sensor of the same dimensions, according to the porosity). This study opens the way to the design and fabrication of wearable flexible pressure sensors with adjustable performances through the control of the porosity of the fabricated PDMS foams.


Nanoscale ◽  
2021 ◽  
Vol 13 (12) ◽  
pp. 6076-6086
Author(s):  
Gen-Wen Hsieh ◽  
Shih-Rong Ling ◽  
Fan-Ting Hung ◽  
Pei-Hsiu Kao ◽  
Jian-Bin Liu

Zinc oxide tetrapod is introduced for the first time within a poly(dimethylsiloxane) dielectric matrix for the formation of ultrasensitive piezocapacitive pressure sensors.


Author(s):  
Masaki Michihata ◽  
Zhao Zheng ◽  
Daiki Funaiwa ◽  
Sojiro Murakami ◽  
Shotaro Kadoya ◽  
...  

AbstractIn this paper, we propose an in-process measurement method of the diameter of micro-optical fiber such as a tapered optical fiber. The proposed technique is based on analyzing optically scattered light generated by standing wave illumination. The proposed method is significant in that it requires an only limited measurement range and does not require a high dynamic range sensor. These properties are suitable for in-process measurement. This experiment verified that the proposed method could measure a fiber diameter as stable as ± 0.01 μm under an air turbulence environment. As a result of comparing the measured diameter distribution with those by scanning electron microscopy, it was confirmed that the proposed method has a measurement accuracy better than several hundred nanometers.


Water ◽  
2021 ◽  
Vol 13 (13) ◽  
pp. 1842
Author(s):  
Ziv Mor ◽  
Hallel Lutzky ◽  
Eyal Shalev ◽  
Nadav G. Lensky

Density, temperature, salinity, and hydraulic head are physical scalars governing the dynamics of aquatic systems. In coastal aquifers, lakes, and oceans, salinity is measured with conductivity sensors, temperature is measured with thermistors, and density is calculated. However, in hypersaline brines, the salinity (and density) cannot be determined by conductivity measurements due to its high ionic strength. Here, we resolve density measurements using a hydrostatic densitometer as a function of an array of pressure sensors and hydrostatic relations. This system was tested in the laboratory and was applied in the Dead Sea and adjacent aquifer. In the field, we measured temporal variations of vertical profiles of density and temperature in two cases, where water density varied vertically from 1.0 × 103 kg·m−3 to 1.24 × 103 kg·m−3: (i) a borehole in the coastal aquifer, and (ii) an offshore buoy in a region with a diluted plume. The density profile in the borehole evolved with time, responding to the lowering of groundwater and lake levels; that in the lake demonstrated the dynamics of water-column stratification under the influence of freshwater discharge and atmospheric forcing. This method allowed, for the first time, continuous monitoring of density profiles in hypersaline bodies, and it captured the dynamics of density and temperature stratification.


2017 ◽  
Vol 2017 ◽  
pp. 1-7
Author(s):  
Mazhyn K. Skakov ◽  
Nurzhan Ye. Mukhamedov ◽  
Alexander D. Vurim ◽  
Ilya I. Deryavko

For the first time the paper determines thermophysical properties (specific heat capacity, thermal diffusivity, and heat conductivity) of the full-scale corium of the fast energy nuclear reactor within the temperature range from ~30°С to ~400°С. Obtained data are to be used in temperature fields calculations during modeling the processes of corium melt retention inside of the fast reactor vessel.


2007 ◽  
Vol 233 ◽  
pp. 584-591 ◽  
Author(s):  
Julien De Rouck ◽  
Björn Van de Walle ◽  
Peter Troch ◽  
Jentsje van der Meer ◽  
Luc Van Damme ◽  
...  

2008 ◽  
Vol 54 (6) ◽  
pp. 956-963 ◽  
Author(s):  
Michael Hartmann ◽  
Monika Schrenk ◽  
Anette Döttinger ◽  
Sarah Nagel ◽  
Johan Roeraade ◽  
...  

Abstract Background: The concurrent detection and quantification of analytes that vary widely in concentration present a principal problem in multiplexed assay systems. Combining competitive and sandwich immunoassays permits coverage of a wide concentration range, and both highly abundant molecules and analytes present in low concentration can be quantified within the same assay. Methods: The use of different fluorescence readout channels allows the parallel use of a competitive system and a sandwich configuration. The 2 generated assay signals are combined and used to calculate the amount of analyte. The measurement range can be adjusted by varying the competitor concentration, and an extension of the assay system’s dynamic range is possible. Results: We implemented the method in a planar protein microarray–based autoimmune assay to detect autoantibodies against 13 autoantigens and to measure the concentration of a highly abundant protein, total human IgG, in one assay. Our results for autoantibody detection and IgG quantification agreed with results obtained with commercially available assays. The use of 2 readout channels in the protein microarray–based system reduced spot-to-spot variation and intraassay variation. Conclusions: By combining a direct immunoassay with a competitive system, analytes present in widely varying concentrations can be quantified within a single multiplex assay. Introducing a second readout channel for analyte quantification is an effective tool for spot-to-spot normalization and helps to lower intraassay variation.


1998 ◽  
Vol 14 (04) ◽  
pp. 265-276
Author(s):  
Ivo Senjanovic

This review paper covers extensive investigations which were undertaken in order to verify the idea of launching of ships and other floating structures from a horizontal berth by a set of turning pads. This includes structural dynamics during launching, model tests and strength analysis of the structure and the launching system. The most important results, which were used for the design of the launching system, are presented. The preparation of a barge for side launching is described, and the full-scale measurement results are compared with the test results. The advantages of building ships and offshore structures on a horizontal berth are pointed out in the conclusion.


2014 ◽  
Vol 23 (01) ◽  
pp. 1450004 ◽  
Author(s):  
XIAOBO XUE ◽  
XIAOLEI ZHU ◽  
QIFENG SHI ◽  
LENIAN HE

In this paper, a 12-bit current-steering digital-to-analog converter (DAC) employing a deglitching technique is proposed. The deglitching technique is realized by lowering the voltage swing of the control signal as well as by using a method of glitch counteraction (GC). A new switch–driver structure is designed to enable the effectiveness of the GC and provide sufficient driving capability under a low supply voltage. Moreover, the control signal's rise/fall asymmetry which increases the glitch error can be suppressed by using the proposed switch–driver structure. The 12-bit DAC is implemented in 180 nm CMOS technology. The measurement results show that the spurious free dynamic range (SFDR) at low signal frequency is 78.8 dB, and it is higher than 70 dB up to 60 MHz signal frequency at 400 MS/s. The measured INL and DNL are both less than ±0.6 LSB.


Sign in / Sign up

Export Citation Format

Share Document