scholarly journals A Fast Calibration Method for Photonic Mixer Device Solid-State Array Lidars

Sensors ◽  
2019 ◽  
Vol 19 (4) ◽  
pp. 822 ◽  
Author(s):  
Yayu Zhai ◽  
Ping Song ◽  
Xiaoxiao Chen

The photonic mixer device (PMD) solid-state array lidar, as a three-dimensional imaging technology, has attracted research attention in recent years because of its low cost, high frame rate, and high reliability. To address the disadvantages of traditional PMD solid-state array lidar calibration methods, including low calibration efficiency and accuracy, and serious human error factors, this paper first proposes a calibration method for an array complementary metal–oxide–semiconductor photodetector using a black-box calibration device and an electrical analog delay method; it then proposes a modular lens distortion correction method based on checkerboard calibration and pixel point adaptive interpolation optimization. Specifically, the ranging error source is analyzed based on the PMD solid-state array lidar imaging mechanism; the black-box calibration device is specifically designed for the calibration requirements of anti-ambient light and an echo reflection route; a dynamic distance simulation system integrating the laser emission unit, laser receiving unit, and delay control unit is designed to calibrate the photodetector echo demodulation; the checkerboard calibration method is used to correct external lens distortion in grayscale mode; and the pixel adaptive interpolation strategy is used to reduce distortion of distance images. Through analysis of the calibration process and results, the proposed method effectively reduces the calibration scene requirements and human factors, meets the needs of different users of the lens, and improves both calibration efficiency and measurement accuracy.

Sensors ◽  
2020 ◽  
Vol 20 (13) ◽  
pp. 3695 ◽  
Author(s):  
Carlos Ricolfe-Viala ◽  
Alicia Esparza

Accurate correction of high distorted images is a very complex problem. Several lens distortion models exist that are adjusted using different techniques. Usually, regardless of the chosen model, a unique distortion model is adjusted to undistort images and the camera-calibration template distance is not considered. Several authors have presented the depth dependency of lens distortion but none of them have treated it with highly distorted images. This paper presents an analysis of the distortion depth dependency in strongly distorted images. The division model that is able to represent high distortion with only one parameter is modified to represent a depth-dependent high distortion lens model. The proposed calibration method obtains more accurate results when compared to existing calibration methods.


2021 ◽  
Vol 2021 ◽  
pp. 1-9
Author(s):  
Hao Zhu ◽  
Mulan Wang ◽  
Weiye Xu

In binocular vision inspection system, the calibration of detection equipment is the basis to ensure the subsequent detection accuracy. The current calibration methods have the disadvantages of complex calculation, low precision, and poor operability. In order to solve the above problems, the calibration method of binocular camera, the correction method of lens distortion, and the calibration method of projector in the binocular vision system based on surface structured light are studied in this paper. For lens distortion correction, on the basis of analyzing the traditional correction methods, a distortion correction method based on radial basis function neural network is proposed. Using the excellent nonlinear mapping ability of RBF neural network, the distortion correction models of different lenses can be obtained quickly. It overcomes the defect that the traditional correction model cannot adjust adaptively with the type of lens. The experimental results show that the accuracy of the method can meet the requirements of system calibration.


Sensors ◽  
2020 ◽  
Vol 20 (24) ◽  
pp. 7329
Author(s):  
Xuanquan Wang ◽  
Ping Song ◽  
Wuyang Zhang

As a typical application of indirect-time-of-flight (ToF) technology, photonic mixer device (PMD) solid-state array Lidar has gained rapid development in recent years. With the advantages of high resolution, frame rate and accuracy, the equipment is widely used in target recognition, simultaneous localization and mapping (SLAM), industrial inspection, etc. The PMD Lidar is vulnerable to several factors such as ambient light, temperature and the target feature. To eliminate the impact of such factors, a proper calibration is needed. However, the conventional calibration methods need to change several distances in large areas, which result in low efficiency and low accuracy. To address the problems, this paper presents an improved calibration method based on electrical analog delay. The method firstly eliminates the lens distortion using a self-adaptive interpolation algorithm, meanwhile it calibrates the grayscale image using an integral time simulating based method. Then, the grayscale image is used to estimate the parameters of ambient light compensation in depth calibration. Finally, by combining four types of compensation, the method effectively improves the performance of depth calibration. Through several experiments, the proposed method is more adaptive to multiscenes with targets of different reflectivities, which significantly improves the ranging accuracy and adaptability of PMD Lidar.


Sensors ◽  
2021 ◽  
Vol 21 (3) ◽  
pp. 765
Author(s):  
Hugo Álvarez ◽  
Marcos Alonso ◽  
Jairo R. Sánchez ◽  
Alberto Izaguirre

This paper describes a method for calibrating multi camera and multi laser 3D triangulation systems, particularly for those using Scheimpflug adapters. Under this configuration, the focus plane of the camera is located at the laser plane, making it difficult to use traditional calibration methods, such as chessboard pattern-based strategies. Our method uses a conical calibration object whose intersections with the laser planes generate stepped line patterns that can be used to calculate the camera-laser homographies. The calibration object has been designed to calibrate scanners for revolving surfaces, but it can be easily extended to linear setups. The experiments carried out show that the proposed system has a precision of 0.1 mm.


Robotica ◽  
2021 ◽  
pp. 1-22
Author(s):  
Zhouxiang Jiang ◽  
Min Huang

SUMMARY In typical calibration methods (kinematic or non-kinematic) for serial industrial robot, though measurement instruments with high resolutions are adopted, measurement configurations are optimized, and redundant parameters are eliminated from identification model, calibration accuracy is still limited under measurement noise. This might be because huge gaps still exist among the singular values of typical identification Jacobians, thereby causing the identification models ill conditioned. This paper addresses such problem by using new identification models established in two steps. First, the typical models are divided into the submodels with truncated singular values. In this way, the unknown parameters corresponding to the abnormal singular values are removed, thereby reducing the condition numbers of the new submodels. However, these models might still be ill conditioned. Therefore, the second step is to further centralize the singular values of each submodel by using a matrix balance method. Afterward, all submodels are well conditioned and obtain much higher observability indices compared with those of typical models. Simulation results indicate that significant improvements in the stability of identification results and the identifiability of unknown parameters are acquired by using the new identification submodels. Experimental results indicate that the proposed calibration method increases the identification accuracy without incurring additional hardware setup costs to the typical calibration method.


Sensors ◽  
2020 ◽  
Vol 21 (1) ◽  
pp. 139
Author(s):  
Shengli Chen ◽  
Xiaobing Zheng ◽  
Xin Li ◽  
Wei Wei ◽  
Shenda Du ◽  
...  

To calibrate the low signal response of the ocean color (OC) bands and test the stability of the Fengyun-3D (FY-3D)/Medium Resolution Spectral Imager II (MERSI-II), an absolute radiometric calibration field test of FY-3D/MERSI-II at the Lake Qinghai Radiometric Calibration Site (RCS) was carried out in August 2018. The lake surface and atmospheric parameters were mainly measured by advanced observation instruments, and the MODerate spectral resolution atmospheric TRANsmittance algorithm and computer model (MODTRAN4.0) was used to simulate the multiple scattering radiance value at the altitude of the sensor. The results showed that the relative deviations between bands 9 and 12 are within 5.0%, while the relative deviations of bands 8, and 13 are 17.1%, and 12.0%, respectively. The precision of the calibration method was verified by calibrating the Aqua/Moderate-resolution Imaging Spectroradiometer (MODIS) and National Polar-orbiting Partnership (NPP)/Visible Infrared Imaging Radiometer (VIIRS), and the deviation of the calibration results was evaluated with the results of the Dunhuang RCS calibration and lunar calibration. The results showed that the relative deviations of NPP/VIIRS were within 7.0%, and the relative deviations of Aqua/MODIS were within 4.1% from 400 nm to 600 nm. The comparisons of three on-orbit calibration methods indicated that band 8 exhibited a large attenuation after launch and the calibration results had good consistency at the other bands except for band 13. The uncertainty value of the whole calibration system was approximately 6.3%, and the uncertainty brought by the field surface measurement reached 5.4%, which might be the main reason for the relatively large deviation of band 13. This study verifies the feasibility of the vicarious calibration method at the Lake Qinghai RCS and provides the basis and reference for the subsequent on-orbit calibration of FY-3D/MERSI-II.


Robotics ◽  
2021 ◽  
Vol 10 (1) ◽  
pp. 45
Author(s):  
Roberto Pagani ◽  
Cristina Nuzzi ◽  
Marco Ghidelli ◽  
Alberto Borboni ◽  
Matteo Lancini ◽  
...  

Since cobots are designed to be flexible, they are frequently repositioned to change the production line according to the needs; hence, their working area (user frame) needs to be often calibrated. Therefore, it is important to adopt a fast and intuitive user frame calibration method that allows even non-expert users to perform the procedure effectively, reducing the possible mistakes that may arise in such contexts. The aim of this work was to quantitatively assess the performance of different user frame calibration procedures in terms of accuracy, complexity, and calibration time, to allow a reliable choice of which calibration method to adopt and the number of calibration points to use, given the requirements of the specific application. This has been done by first analyzing the performances of a Rethink Robotics Sawyer robot built-in user frame calibration method (Robot Positioning System, RPS) based on the analysis of a fiducial marker distortion obtained from the image acquired by the wrist camera. This resulted in a quantitative analysis of the limitations of this approach that only computes local calibration planes, highlighting the reduction of performances observed. Hence, the analysis focused on the comparison between two traditional calibration methods involving rigid markers to determine the best number of calibration points to adopt to achieve good repeatability performances. The analysis shows that, among the three methods, the RPS one resulted in very poor repeatability performances (1.42 mm), while the three and five points calibration methods achieve lower values (0.33 mm and 0.12 mm, respectively) which are closer to the reference repeatability (0.08 mm). Moreover, comparing the overall calibration times achieved by the three methods, it is shown that, incrementing the number of calibration points to more than five, it is not suggested since it could lead to a plateau in the performances, while increasing the overall calibration time.


2013 ◽  
Vol 475-476 ◽  
pp. 184-187
Author(s):  
Wen Guo Li ◽  
Shao Jun Duan

We present a camera calibration method based on circle plane board. The centres of circles on plane are regarded as the characteristic points, which are used to implement camera calibration. The proposed calibration is more accurate than many previous calibration algorithm because of the merit of the coordinate of circle centre being obtained from thousand of of edge pionts of ellipse, which is very reliable to image noise caused by edge extraction algorithm. Experiments shows the proposed algorithm can obtain high precise inner parameters, and lens distortion parameters.


2012 ◽  
Vol 496 ◽  
pp. 281-284
Author(s):  
Wen Wen Liu ◽  
Zhi Wang ◽  
Yun Hai Du ◽  
Xian Zhong Xu ◽  
Da Quan Liu ◽  
...  

An improved accurate speckle projection method is used for study the mechanical properties of the composite material film in the paper. A system for deformation measurement is developed with the telecentric lenses, in which such conventional lens’ disadvantages such as lens distortion and perspective error will be diminished. Experiments are performed to validate the availability and reliability of the calibration method. The system can also be used to measure the dynamic deformation and then results are also given.


2000 ◽  
Vol 407 (1-2) ◽  
pp. 23-39 ◽  
Author(s):  
John-Erik Haugen ◽  
Oliver Tomic ◽  
Knut Kvaal

Sign in / Sign up

Export Citation Format

Share Document