scholarly journals Ambulatory Evaluation of ECG Signals Obtained Using Washable Textile-Based Electrodes Made with Chemically Modified PEDOT:PSS

Sensors ◽  
2019 ◽  
Vol 19 (2) ◽  
pp. 416 ◽  
Author(s):  
Amale Ankhili ◽  
Xuyuan Tao ◽  
Cédric Cochrane ◽  
Vladan Koncar ◽  
David Coulon ◽  
...  

A development of washable PEDOT:PSS (poly(3,4-ethylenedioxythiophene) polystyrene sulfonate) polyamide textile-based electrodes is an interesting alternative to the traditional Ag/AgCl disposable electrodes, usually used in clinical practice, helping to improve medical assessment and treatment before apparition or progress of patients’ cardiovascular symptoms. This study was conducted in order to determine whether physical properties of PEDOT:PSS had a significant impact on the coated electrode’s electrocardiogram (ECG) signal quality, particularly after 50 washing cycles in a domestic laundry machine. Tests performed, included the comparison of two PEDOT:PSS solutions, in term of viscosity with emphasis on wetting tests, including surface tension and contact angle measurements. In addition, polyamide textile fabrics were used as substrate to make thirty electrodes and to characterize the amount of PEDOT:PSS absorbed as a function of time. The results showed that surface tension of PEDOT:PSS had a significant impact on the wetting of polyamide textile fabric and consequently on the absorbed amount. In fact, lower values of surface tension of the solution lead to low values contact angles between PEDOT:PSS and textile fabric (good wettability). Before washing, no significant difference has been observed among signal-to-noise ratios measured (SNR) for coated electrodes by the two PEDOT:PSS solutions. However, after 50 washing cycles, SNR decreased strongly for electrodes coated by the solution that had low viscosity, since it contained less solid contents. That was confirmed by scanning electron microscopy images (SEM) and also by analyzing the color change of electrodes based on the calculation of CIELAB color space coordinates. Moreover, spectral power density of recorded ECG signals has been computed and presented. All cardiac waves were still visible in the ECG signals after 50 washing cycles. Furthermore, an experienced cardiologist considered that all the ECG signals acquired were acceptable. Accordingly, our newly developed polyamide textile-based electrodes seem to be suitable for long-term monitoring. The study also provided new insights into the better choice of PEDOT:PSS formulation as a function of a specific process in order to manufacture cheaper electrodes faster.

1979 ◽  
Vol 23 (89) ◽  
pp. 57-66 ◽  
Author(s):  
J.-P. Benoist

Abstract Longitudinal profiles of roches moutonnées have been measured once every centimetre over a total length of more than 100 m. Only wavelengths in the range 3.6 cm < λ < 40 cm have been kept and analysed. Levels and their slopes have a symmetrical, non-Gaussian distribution. The spectral power density varies roughly as γ 0 ν–n (ν ═ wavenumber ═ 1/λ); n being the same for all the profiles (n ═ 2.36) and γ 0 being dependent on the studied area. No significant difference has been found for the shadowing function of the different studied areas. It differs consistently from Smith’s theoretical function.


1979 ◽  
Vol 23 (89) ◽  
pp. 57-66 ◽  
Author(s):  
J.-P. Benoist

AbstractLongitudinal profiles of roches moutonnées have been measured once every centimetre over a total length of more than 100 m. Only wavelengths in the range 3.6 cm < λ < 40 cm have been kept and analysed. Levels and their slopes have a symmetrical, non-Gaussian distribution. The spectral power density varies roughly as γ0ν–n (ν ═ wavenumber ═ 1/λ); n being the same for all the profiles (n ═ 2.36) and γ0 being dependent on the studied area. No significant difference has been found for the shadowing function of the different studied areas. It differs consistently from Smith’s theoretical function.


2020 ◽  
Vol 45 (6) ◽  
pp. 589-597
Author(s):  
BGS Casado ◽  
EP Pellizzer ◽  
JR Souto Maior ◽  
CAA Lemos ◽  
BCE Vasconcelos ◽  
...  

Clinical Relevance The use of laser light during bleaching will not reduce the incidence or severity of sensitivity and will not increase the degree of color change compared with nonlaser light sources. SUMMARY Objective: To evaluate whether the use of laser during in-office bleaching promotes a reduction in dental sensitivity after bleaching compared with other light sources. Methods: The present review was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) and is registered with PROSPERO (CDR42018096591). Searches were conducted in the PubMed/Medline, Web of Science, and Cochrane Library databases for relevant articles published up to August 2018. Only randomized clinical trials among adults that compared the use of laser during in-office whitening and other light sources were considered eligible. Results: After analysis of the texts retrieved during the database search, six articles met the eligibility criteria and were selected for the present review. For the outcome dental sensitivity, no significant difference was found favoring any type of light either for intensity (mean difference [MD]: −1.60; confidence interval [CI]: −3.42 to 0.22; p=0.09) or incidence (MD: 1.00; CI: 0.755 to 1.33; p=1.00). Regarding change in tooth color, no significant differences were found between the use of the laser and other light sources (MD: −2.22; CI: −6.36 to 1.93; p=0.29). Conclusions: Within the limitations of the present study, laser exerts no influence on tooth sensitivity compared with other light sources when used during in-office bleaching. The included studies demonstrated that laser use during in-office bleaching may have no influence on tooth color change.


Author(s):  
Rami Benkreif ◽  
Fatima Zohra Brahmia ◽  
Csilla Csiha

AbstractSurface tension of solid wood surfaces affects the wettability and thus the adhesion of various adhesives and wood coatings. By measuring the contact angle of the wood, the surface tension can be calculated based on the Young-Dupré equation. Several publications have reported on contact angle measured with different test liquids, under different conditions. Results can only be compared if the test conditions are similar. While the roles of the drop volume, image shooting time etc., are widely recognized, the role of the wood surface moisture content (MC) is not evaluated in detail. In this study, the effect of wood moisture content on contact angle values, measured with distilled water and diiodomethane, on sanded birch (Betula pendula) surfaces was investigated, in order to find the relationship between them. With increasing MC from approximately 6% to 30%, increasing contact angle (decreasing surface tension) values were measured according to a logarithmic function. The function makes possible the calculation of contact angles that correspond to different MCs.


Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4215
Author(s):  
Radosław Wróbel ◽  
Lech Sitnik ◽  
Monika Andrych-Zalewska ◽  
Łukasz Łoza ◽  
Radostin Dimitrov ◽  
...  

The article presents the results of research on the vibroacoustic response of internal combustion engines mounted in a vehicle. The vehicles studied belong to popular models, which became available in successive versions. Each group included vehicles of the same model of an older generation (equipped with a naturally aspirated engine) and of a newer generation, including downsized (and turbocharged) engines. Tests in each group were carried out under repeatable conditions on a chassis-load dynamometer. The vibrations were measured using single-axis accelerometers mounted on the steering wheel, engine, and driver’s head restraint mounting. The primary purpose of the study was to verify whether the new generations of vehicles equipped with additional high-speed elements (compressors) generate additional harmonics (especially those within the range potentially affecting travel comfort and human health) and whether there are significant changes in the distribution of spectral power density in the new generations. As the study showed, new generations of vehicles are characterized by a different vibroacoustic response, and the trend of change is the same in each of the families studied.


2020 ◽  
Vol 42 (2) ◽  
Author(s):  
Thomas Leitner ◽  
Anna Werkovits ◽  
Siegfried Kleber ◽  
Gernot Pottlacher

AbstractW360 is a hot work tool steel produced by voestalpine BÖHLER Edelstahl GmbH & Co KG, a special steel producer located in Styria, Austria. Surface tension and density of liquid W360 were studied as a function of temperature in a non-contact, containerless fashion using the oscillating drop method inside an electromagnetic levitation setup. For both, surface tension and density, a linear model was adapted to present the temperature dependence of these measures, including values for the uncertainties of the fit parameters found. The data obtained are compared to pure iron (with 91 wt% the main component of W360), showing an overlap for the liquid density while there is a significant difference in surface tension (− 5.8 % at the melting temperature of pure iron of 1811 K).


2015 ◽  
Vol 44 (5) ◽  
pp. 262-267 ◽  
Author(s):  
José Vitor Quinelli Mazaro ◽  
Luiz Miguel Minani ◽  
Adriana Cristina Zavanelli ◽  
Caroline Cantieri de Mello ◽  
Cleidiel Aparecido Araújo Lemos

AbstractIntroductionTemporary restorative materials are widely used, however, little is know about their color stability.Objectiveto evaluate the color stability of the following temporary restorative materials: acrylic and bis-acrylic resins after immersion in pigmenting solutions for different periods of storage.Material and methodFour materials were tested (Dêncor/Clássico, Protemp 4/3M ESPE; Structur 2 SC/Voco; Luxatemp AM Plus/DMG) and 30 test specimens (15 mm in diameter and 2 mm thick) per material were fabricated. They were divided according to the storage medium (artificial saliva, saliva + cola type soda, and saliva + coffee) and storage time intervals (2, 5, 7 and 15 days). Color measurements were made before and after immersions, with use of a spectrophotometer, by means of the CIE L*a*b* system. The data were analyzed by the analysis of variance and the Tukey Test, at a level of significance of 5%.ResultAcrylic resin presented greater color stability in comparison with bis-acrylic resins (p<0.001). When bis-acrylic resins were compared no significant difference was observed between the resins Structur and Luxatemp (p=0.767). As regards solutions tested, coffee showed the highest color change values (p<0.001), and the longer the storage time interval, the greater was the color change in all the temporary restorative materials analyzed (p<0.001).ConclusionAcrylic resin presented greater color stability in comparison with bis-acrylic resins (p<0.001). Coffee caused the greatest color change, and immersion time was determinant in color stability of the temporary materials analyzed.


2016 ◽  
Vol 2016 ◽  
pp. 1-8 ◽  
Author(s):  
Gang Zhou ◽  
Han Qiu ◽  
Qi Zhang ◽  
Mao Xu ◽  
Jiayuan Wang ◽  
...  

Wettability is one of the key chemical properties of coal dust, which is very important to dedusting. In this paper, the theory of liquid wetting solid was presented firstly; then, taking the gas coal of Xinglongzhuang coal mine in China as an example, by determination of critical surface tension of coal piece, it can be concluded that only when the surface tension of surfactant solution is less than 45 mN/m can the coal sample be fully wetted. Due to the effect of particle dispersity, compared with the contact angle of milled coal particle, not all the contact angles of screened coal powder with different sizes have a tendency to increase. Furthermore, by the experiments of coal samples’ specific surface areas and porosities, it can be achieved that the volume of single-point total pore decreases with the gradual decreasing of coal’s porosity, while the ultramicropores’ dispersities and multipoint BET specific surface areas increase. Besides, by a series of contact angle experiments with different surfactants, it can be found that with the increasing of porosity and the decreasing of volume percentage of ultramicropore, the contact angle tends to reduce gradually and the coal dust is much easier to get wetted.


Author(s):  
Shoaib Ugradar ◽  
Jane S Kim ◽  
Noelle Trost ◽  
Emanuil Parunakian ◽  
Erin Zimmerman ◽  
...  

Abstract Background Oxymetazoline hydrochloride 0.1% ophthalmic solution has recently been approved in the United States for the treatment of ptosis. Objectives The aim of this study was to assess the upper and lower eyelid position as well as the brow position and the color of the sclera following the ophthalmic administration of oxymetazoline hydrochloride 0.1%. Methods In this prospective cohort study, consecutive patients presenting with ptosis received topical oxymetazoline 0.1%. The primary outcome was measurement of the upper eyelid height (margin-to-reflex distance 1 [MRD1]) and lower eyelid height (MRD2) relative to the center of pupil, along with assessment of brow height, measured on photographs at baseline and 2 hours after instillation of oxymetazoline. The secondary outcome was the assessment of the color of the sclera (eye whiteness) before and after treatment with a novel color space algorithm. Results Twenty-nine patients participated in the study. The mean [SD] MRD1 at baseline was 2.3 [0.6] mm. At 2 hours following oxymetazoline treatment, the mean MRD1 significantly increased to 4.2 [0.9] mm (P &lt; 0.01). The mean MRD2 also significantly increased from 5.3 [0.9] mm to 5.7 [1.0] mm (P &lt; 0.01). Brow position did not change with treatment (P = 0.4). Following treatment, the eye sclera became significantly whiter, with a mean ΔEab (color change) of 9.7 [3.9], with 57 out of 58 eyes experiencing a significant change in color. A change of ΔEab ≥2 is considered visually perceptible to the human eye. Conclusions Within 2 hours of use, oxymetazoline significantly improves the size of the palpebral aperture (MRD1 + MRD2) and also makes the eye appear significantly whiter. Level of Evidence: 4


Sign in / Sign up

Export Citation Format

Share Document