scholarly journals Inflating Source Imaging and Stress/Strain Field Analysis at Campi Flegrei Caldera: The 2009–2013 Unrest Episode

2021 ◽  
Vol 13 (12) ◽  
pp. 2298
Author(s):  
Raffaele Castaldo ◽  
Pietro Tizzani ◽  
Giuseppe Solaro

In this study, we analyze the 2009–2013 uplift phenomenon at Campi Flegrei (CF) caldera in terms of temporal and spatial variations in the stress/strain field due to the effect of an inflating source. We start by performing a 3D stationary finite element (FE) modeling of X-band COSMO-SkyMed DInSAR and GPS mean velocities to retrieve the geometry and location of the deformation source. The modeling results suggest that the best-fit source is a three-axis oblate spheroid ~3 km deep, which is mostly elongated in the NE–SW direction. Furthermore, we verify the reliability of model results by calculating the total horizontal derivative (THD) of the modeled vertical velocity component; the findings emphasize that the THD maxima overlap with the projection of source boundaries at the surface. Then, we generate a 3D time-dependent FE model, comparing the spatial and temporal distribution of the shear stress and volumetric strain with the seismic swarms beneath the caldera. We found that low values of shear stress are observed corresponding with the shallow hydrothermal system where low-magnitude earthquakes occur, whereas high values of shear stress are found at depths of about 3 km, where high-magnitude earthquakes nucleate. Finally, the volumetric strain analysis highlights that the seismicity occurs mainly at the border between compression and dilatation modeled regions, and some seismic events occur within compression regions.

2019 ◽  
Vol 36 (6) ◽  
pp. 1950-1976
Author(s):  
Qing Xie ◽  
Yucai Hu ◽  
Yexin Zhou ◽  
Wanshui Han

Purpose Poor bending response is a major shortcoming of lower-order elements due to excessive representation of shear stress/strain field. Advanced finite element (FE) formulations for classical elasticity enhance the bending response by either nullifying or filtering some of the symmetric shear stress/strain modes. Nevertheless, the stress/strain field in Cosserat elasticity is asymmetric; consequently any attempt to nullify or filter the anti-symmetric shear stress/strain modes may lead to failure in the constant couple-stress patch test where the anti-symmetric shear stress/strain field is linear. This paper aims at enhancing the bending response of lower-order elements for Cosserat elasticity problems. Design/methodology/approach A four-node quadrilateral and an eight-node hexahedron are formulated by hybrid-stress approach. The symmetric stress is assumed as those of Pian and Sumihara and Pian and Tong. The anti-symmetric stress components are first assumed to be completely linear in order to pass the constant couple-stress patch test. The linear modes are then constrained with respect to the prescribed body-couple via the equilibrium conditions. Findings Numerical tests show that the hybrid elements can strictly pass the constant couple-stress patch test and are markedly more accurate than the conventional elements as well as the incompatible elements for bending problems in Cosserat elasticity. Originality/value This paper proposes a hybrid FE formulation to improve the bending response of four-node quadrilateral and eight-node hexahedral elements for Cosserat elasticity problems without compromising the constant couple-stress patch test.


Metals ◽  
2019 ◽  
Vol 9 (6) ◽  
pp. 632 ◽  
Author(s):  
Ahmed M. Sayed

The perforated steel sheets have many uses, so they should be studied under the influence of the uniaxial tensile load. The presence of these holes in the steel sheets certainly affects the mechanical properties. This paper aims at studying the behavior of the stress-strain engineering relationships of the perforated steel sheets. To achieve this, the three-dimensional finite element (FE) model is mainly designed to investigate the effect of this condition. Experimental tests were carried out on solid specimens to be used in the test of model accuracy of the FE simulation. Simulation testing shows that the FE modeling revealed the ability to calculate the stress-strain engineering relationships of perforated steel sheets. It can be concluded that the effect of a perforated rhombus shape is greater than the others, and perforated square shape has no effect on the stress-strain engineering relationships. The efficiency of the perforated staggered or linearly distribution shapes with the actual net area on the applied loads has the opposite effect, as it reduces the load capacity for all types of perforated shapes. Despite the decrease in load capacity, it improves the properties of the steel sheets.


Author(s):  
Milena Rajić ◽  
Dragoljub Živković ◽  
Milan Banić ◽  
Marko Mančić ◽  
Miloš Milošević ◽  
...  

2019 ◽  
Vol 11 (1) ◽  
pp. 69-79 ◽  
Author(s):  
Benedict Jain A.R. Tony ◽  
Masilamany S. Alphin

SummaryStudy aim: Interactions between the fingers and a handle can be analyzed using a finite element finger model. Hence, the biomechanical response of a hybrid human finger model during contact with varying diameter cylindrical handles was investigated numerically in the present study using ABAQUS/CAE.Materials and methods: The finite element index finger model consists of three segments: the proximal, middle, and distal phalanges. The finger model comprises skin, bone, subcutaneous tissue and nail. The skin and subcutaneous tissues were assumed to be non-linearly elastic and linearly visco-elastic. The FE model was applied to predict the contact interaction between the fingers and a handle with 10 N, 20 N, 40 N and 50 N grip forces for four different diameter handles (30 mm, 40 mm, 44mm and 50 mm). The model predictions projected the biomechanical response of the finger during the static gripping analysis with 200 incremental steps.Results: The simulation results showed that the increase in contact area reduced the maximal compressive stress/strain and also the contact pressure on finger skin. It was hypothesized in this study that the diameter of the handle influences the stress/strain and contact pressure within the soft tissue during the contact interactions.Conclusions: The present study may be useful to study the behavior of the finger model under the static gripping of hand-held power tools.


2019 ◽  
Author(s):  
Mazin S. Sirry ◽  
Laura Dubuis ◽  
Neil H. Davies ◽  
Jun Liao ◽  
Thomas Franz

AbstractFinite element (FE) models have been effectively utilized in studying biomechanical aspects of myocardial infarction (MI). Although the rat is a widely used animal model for MI, there is a lack of material parameters based on anisotropic constitutive models for rat myocardial infarcts in literature. This study aimed at employing inverse methods to identify the parameters of an orthotropic constitutive model for myocardial infarcts in the acute, necrotic, fibrotic and remodelling phases utilizing the biaxial mechanical data developed in a previous study. FE model was developed mimicking the setup of the biaxial tensile experiment. The orthotropic case of the generalized Fung constitutive model was utilized to model the material properties of the infarct. The parameters of Fung model were optimized so that the FE solution best fitted the biaxial experimental stress-strain data. A genetic algorithm was used to minimize the objective function. Fung orthotropic material parameters for different infarct stages were identified. The FE model predictions best approximated the experimental data of the 28 days infarct stage with 3.0% mean absolute percentage error. The worst approximation was for the 7 days stage with 3.6% error. This study demonstrated that the experimental biaxial stress-strain data of healing rat infarcts could be successfully approximated using inverse FE methods and genetic algorithms. The material parameters identified in this study will provide an essential platform for FE investigations of biomechanical aspects of MI and the development of therapies.


Sign in / Sign up

Export Citation Format

Share Document