scholarly journals Multi-Parameter Regularization Method for Synthetic Aperture Imaging Radiometers

2021 ◽  
Vol 13 (3) ◽  
pp. 382
Author(s):  
Xiaocheng Yang ◽  
Zhenyi Yang ◽  
Jingye Yan ◽  
Lin Wu ◽  
Mingfeng Jiang

Synthetic aperture imaging radiometers (SAIRs) are powerful passive microwave systems for high-resolution imaging by use of synthetic aperture technique. However, the ill-posed inverse problem for SAIRs makes it difficult to reconstruct the high-precision brightness temperature map. The traditional regularization methods add a unique penalty to all the frequency bands of the solution, which may cause the reconstructed result to be too smooth to retain certain features of the original brightness temperature map such as the edge information. In this paper, a multi-parameter regularization method is proposed to reconstruct SAIR brightness temperature distribution. Different from classical single-parameter regularization, the multi-parameter regularization adds multiple different penalties which can exhibit multi-scale characteristics of the original distribution. Multiple regularization parameters are selected by use of the simplified multi-dimensional generalized cross-validation method. The experimental results show that, compared with the conventional total variation, Tikhonov, and band-limited regularization methods, the multi-parameter regularization method can retain more detailed information and better improve the accuracy of the reconstructed brightness temperature distribution, and exhibit superior noise suppression, demonstrating the effectiveness and the robustness of the proposed method.

2011 ◽  
Vol 36 (4) ◽  
Author(s):  
Ihor Trots ◽  
Yuriy Tasinkevych ◽  
Andrzej Nowicki ◽  
Marcin Lewandowski

Sensors ◽  
2021 ◽  
Vol 21 (7) ◽  
pp. 2275
Author(s):  
Hae Gyun Lim ◽  
Hyung Ham Kim ◽  
Changhan Yoon

High-frequency ultrasound (HFUS) imaging has emerged as an essential tool for pre-clinical studies and clinical applications such as ophthalmic and dermatologic imaging. HFUS imaging systems based on array transducers capable of dynamic receive focusing have considerably improved the image quality in terms of spatial resolution and signal-to-noise ratio (SNR) compared to those by the single-element transducer-based one. However, the array system still suffers from low spatial resolution and SNR in out-of-focus regions, resulting in a blurred image and a limited penetration depth. In this paper, we present synthetic aperture imaging with a virtual source (SA-VS) for an ophthalmic application using a high-frequency convex array transducer. The performances of the SA-VS were evaluated with phantom and ex vivo experiments in comparison with the conventional dynamic receive focusing method. Pre-beamformed radio-frequency (RF) data from phantoms and excised bovine eye were acquired using a custom-built 64-channel imaging system. In the phantom experiments, the SA-VS method showed improved lateral resolution (>10%) and sidelobe level (>4.4 dB) compared to those by the conventional method. The SNR was also improved, resulting in an increased penetration depth: 16 mm and 23 mm for the conventional and SA-VS methods, respectively. Ex vivo images with the SA-VS showed improved image quality at the entire depth and visualized structures that were obscured by noise in conventional imaging.


2014 ◽  
Vol 58 ◽  
pp. 193-203 ◽  
Author(s):  
Jianfei Chen ◽  
Yuehua Li ◽  
Jianqiao Wang ◽  
Yuanjiang Li ◽  
Yilong Zhang

1977 ◽  
Vol 82 (24) ◽  
pp. 3445-3451 ◽  
Author(s):  
David Atlas ◽  
Charles Elachi ◽  
Walter E. Brown

Author(s):  
Tao Yang ◽  
Yanning Zhang ◽  
Jingyi Yu ◽  
Jing Li ◽  
Wenguang Ma ◽  
...  

2013 ◽  
Author(s):  
Qian Xu ◽  
Yu Zhou ◽  
Jianfeng Sun ◽  
Ya'nan Zhi ◽  
Xiaoping Ma ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document