scholarly journals Polarimetric Calibration of the GaoFen-3 Mission Using Active Radar Calibrators and the Applicable Conditions of System Model for Radar Polarimeters

2019 ◽  
Vol 11 (2) ◽  
pp. 176 ◽  
Author(s):  
Weibin Liang ◽  
Zengzeng Jia ◽  
Xiaolan Qiu ◽  
Jun Hong ◽  
Qingjun Zhang ◽  
...  

GaoFen-3, the first polarimetric SAR satellite of China, carried out polarimetric calibration experiments using C-band polarimetric active radar calibrators (PARCs), trihedral corner reflectors (TCRs), and dihedral corner reflectors (DCRs). The calibration data were firstly processed referring to the classic 2 × 2 receive R and transmit T model for radar polarimeter systems, first proposed by Zebker, Zyl, and Held, and Freeman’s method based on PARCs, but the results were not good enough. After detailed analysis about the GaoFen-3 polarimetric system, we found that the system had some nonlinearity, then a new imbalance parameter was introduced to the classic model, which is equivalent to the γ proposed in Freeman’s paper about a general polarimetric system model. Then, we proposed the calibration data processing algorithm for GaoFen-3 based on the improved model and obtained better results. The algorithm proposed here is verified to be suitable for GaoFen-3 and can be applied to other spaceborne and airborne fully-polarimetric SAR systems.

2021 ◽  
pp. 464-468
Author(s):  
A.D. Tikhonov ◽  
A.A. Kochiev

The article deals with determination of coordinates using global navigation systems, and application of the PPP data processing algorithm to obtain coordinates. The authors conducted an experiment illustrating the algorithm accuracy.


2018 ◽  
Vol 10 (12) ◽  
pp. 2060 ◽  
Author(s):  
Yoon Jung ◽  
Sang-Eun Park

In the diverse applications of polarimetric Synthetic Aperture Radar (SAR) systems, it is a crucial to conduct polarimetric calibration, which aims to remove the radar system distortion effects prior to utilizing polarimetric SAR observations. The objective of this study is to evaluate the performance of different polarimetric calibration methods. Two widely used methods, the Van Zyl and Quegan methods, and one recently proposed method, such as the Villa method, have been selected among various calibration methods in literature. The selected methods have basic differences in their assumptions that are applied to the polarimetric system model. In order to evaluate the calibration performances under different system parameters and ground characteristics, comparative analysis of the calibration results were conducted on synthetic polarimetric SAR data and ALOS PALSAR quad-pol mode data. Based on the experimental results, the advantages and limitations of different methods were clarified, and a simple hybrid calibration method is presented to further improve the polarimetric calibration performance.


Metallomics ◽  
2014 ◽  
Vol 6 (8) ◽  
pp. 1387-1389
Author(s):  
Tomasz K. Wojdacz ◽  
Matteo Bottai ◽  
Marie Vahter ◽  
Karin Broberg

The 450k Chip Analysis Methylation Pipeline (ChAMP) is a novel Illumina Infinium HumanMethylation450 BeadChip data processing algorithm that allows the analysis of copy number alterations (CNAs).


Sign in / Sign up

Export Citation Format

Share Document