scholarly journals Effect of Two- and Three-Dimensionally Designed Guide Vanes with Different Camber Length on Static Pressure Recovery of a Wall-Mounted Axial Fan

Processes ◽  
2021 ◽  
Vol 9 (9) ◽  
pp. 1595
Author(s):  
Yong-In Kim ◽  
Yong-Uk Choi ◽  
Cherl-Young Jeong ◽  
Kyoung-Yong Lee ◽  
Young-Seok Choi

This study was based on a numerical effort to use the motor support (prop) as a guide vane when the motor of a wall-mounted axial fan was located at the fan outlet while maintaining the structural and spatial advantage. The design for the guide vane followed two- and three-dimensional methods. The inlet vane angle, meridional length (total), and meridional length with a vane angle of zero (0) degrees (linear) were considered as design variables. At the design and some low flow rate points, the 2D design offered the most favorable performance when the meridional length with a vane angle of zero (0) degrees (linear) was 30% based on total length, and was the worst for 70%. The 3D design method applied in this study did not outperform the 2D design. In the 2D design concept, averaging the flow angle for the entire span at the design flow rate could ensure a better pressure rise over a more comprehensive flow rate range than weighting the flow angle for a specific span. In addition, the numerical results were validated through an experimental test, with an important discussion of the swirl (dynamic pressure) component. The influence of the inlet motor and turbulence model are presented as a previous confirmation.

2020 ◽  
Vol 142 (10) ◽  
Author(s):  
Hiroshi Yokoyama ◽  
Katsutake Minowa ◽  
Kohei Orito ◽  
Masahito Nishikawara ◽  
Hideki Yanada

Abstract Small axial fans are used for cooling electronic equipment and are often installed in a casing with various slits. Direct aeroacoustic simulations and experiments were performed with different casing opening ratios to clarify the effects of the flow through the casing slits on the flow field and acoustic radiation around a small axial fan. Both the predicted and measured results show that aerodynamic performance deteriorates at and near the design flow rate and is higher at low flow rates by completely closing the casing slits compared with the fan in the casing with slits. The predicted flow field shows that the vortical structures in the tip vortices are spread by the suppression of flow through the slits at the design flow rate, leading to the intensification of turbulence in the blade wake. Moreover, the pressure fluctuations on the blade surface are intensified, which increases the aerodynamic sound pressure level. The suppression of the outflow of pressurized air through the downstream part of the slits enhances the aerodynamic performance at low flow rates. Also, the predicted surface streamline at the design flow rate shows that air flows along the blade tip for the fan with slits, whereas the flow toward the blade tip appears for the fan without slits. As a result, the pressure distributions on the blade and the torque exerted on the fan blade are affected by the opening ratio of slits.


2018 ◽  
Vol 17 (1-2) ◽  
pp. 159-183 ◽  
Author(s):  
Tao Zhu ◽  
Thomas H Carolus

The effect of tip clearance in an axial fan on its aerodynamic and aeroacoustic performance is investigated experimentally as well as via a Lattice–Boltzmann flow simulation method. An increase in tip clearance degrades fan pressure rise and efficiency, but also increases significantly the overall sound power emitted by the fan. A large tip clearance causes a clear structure of well distinguishable unsteady vortices which interact with neighboring blades and hence produce an increase in broadband sound. Moreover, if, compared to the design flow rate, there is a moderate flow rate reduction, the local tip vortex systems of all individual blade tips form a circumferentially coherent flow structure, resulting in distinct humps of sound pressure in the acoustic far field. By means of a rigid ring-type protrusion fixed to the inner casing wall, the generation of the tip clearance vortices and slowly rotating coherent flow structures could be suppressed. As a consequence, the sound emitted by the fan is substantially reduced.


Author(s):  
Corine Meuleman ◽  
Frank Willems ◽  
Rick de Lange ◽  
Bram de Jager

Surge is measured in a low-speed radial compressor with a vaned diffuser. For this system, the flow coefficient at surge is determined. This coefficient is a measure for the inducer inlet flow angle and is found to increase with increasing rotational speed. Moreover, the frequency and amplitude of the pressure oscillations during fully-developed surge are compared with results obtained with the Greitzer lumped parameter model. The measured surge frequency increases when the compressor mass flow is throttled to a smaller flow rate. Simulations show that the Greitzer model describes this relation reasonably well except for low rotational speeds. The predicted amplitude of the pressure rise oscillations is approximately two times too small when deep surge is met in the simulations. For classic surge, the agreement is worse. The amplitude is found to depend strongly on the shape of the compressor and throttle characteristic, which are not accurately known.


Author(s):  
Hucan Hou ◽  
Yongxue Zhang ◽  
Zhenlin Li ◽  
Xin Zhou ◽  
Zizhe Wang

In order to effectively improve hydraulic performance of centrifugal pump on off-conditions, the hydraulic design of inlet guide vane (IGV) was completed by adopting two dimensional theory in-house code based on one kind of IS series of centrifugal pump, which can achieve pre-whirl regulation of centrifugal pump. During design process the trailing edge of vane is assumed as equal velocity moment condition, and the distribution of vane setting angle along meridional streamline is also given as a quartic function firstly, the camber line is then drawn by point-by-point integration method and thickened at both sides along circumferential direction. With local vortex dynamics diagnosis theory, the optimal improvement of vane space shape can be finished by adjusting the design parameters of vane setting angle distribution coefficient ap. The full flow passage numerical simulations of centrifugal pump with IGV device are completed to analyze the influence of pre-whirl regulation on hydraulic performance of centrifugal pump under various pre-whirl angles. The results show that the pre-whirl regulation can improve the hydraulic performance of centrifugal pump on off-conditions. Under the positive pre-whirl regulation conditions, the best efficient point shift to small flow rate zone, and under the negative pre-whirl regulation conditions it moves to large flow rate zone. Compared with the pump without IGV device at the same flow rate condition of 0.8Q (Q the design flow rate), the hydraulic efficiency of centrifugal pump with IGV device improves obviously and reaches up to 1.43%. Meanwhile compared with that installed with the straight vanes designed based on the traditional theory, the inner flow field of centrifugal pump with the designed vanes improves and the overall hydraulic efficiency of centrifugal pump is somewhat increased.


Author(s):  
S. M. Miner ◽  
R. D. Flack ◽  
P. E. Allaire

Two dimensional potential flow was used to determine the velocity field within a laboratory centrifugal pump. In particular, the finite element technique was used to model the impeller and volute simultaneously. The rotation of the impeller within the volute was simulated by using steady state solutions with the impeller in 10 different angular orientations. This allowed the interaction between the impeller and the volute to develop naturally as a result of the solution. The results for the complete pump model showed that there are circumferential asymmetries in the velocity field, even at the design flow rate. Differences in the relative velocity components were as large as 0.12 m/sec for the radial component and 0.38 m/sec for the tangential component, at the impeller exit. The magnitude of these variations was roughly 25% of the magnitude of the average radial and tangential velocities at the impeller exit. These asymmetries were even more pronounced at off design flow rates. The velocity field was also used to determine the location of the tongue stagnation point and to calculate the slip within the impeller. The stagnation point moved from the discharge side of the tongue to the impeller side of the tongue, as the flow rate increased from below design flow to above design flow. At design flow, values of slip ranged from 0.96 to 0.71, from impeller inlet to impeller exit. For all three types of data (velocity profiles, stagnation point location, and slip factor) comparison was made to laser velocimeter data, taken for the same pump. At the design flow, the computational and experimental results agreed to within 17% for the velocity magnitude, and 2° for the flow angle. The stagnation point locations coincided for the computational and experimental results, and the values for slip agreed to within 10%.


Author(s):  
Ja´nos Vad ◽  
Ali R. A. Kwedikha ◽  
Helmut Jaberg

Experimental and computational studies were carried out in order to survey the energetic aspects of forward and backward sweep in axial flow rotors of low aspect ratio blading for incompressible flow. It has been pointed out that negative sweep tends to increase the lift, the flow rate and the ideal total pressure rise in the vicinity of the endwalls. Just the opposite tendency was experienced for positive sweep. The local losses were found to develop according to combined effects of sweep near the endwalls, endwall and tip clearance losses, and profile drag influenced by re-arrangement of the axial velocity profile. The forward-swept bladed rotor showed reduced total efficiency compared to the unswept and swept-back bladed rotors. This behavior has been explained on the basis of analysis of flow details. It has been found that the swept bladings of low aspect ratio tend to retain the performance of the unswept datum rotor even in absence of sweep correction.


1991 ◽  
Author(s):  
Ronald D. Flack ◽  
Steven M. Miner ◽  
Ronald J. Beaudoin

Turbulence profiles were measured in a centrifugal pump with an impeller with backswept blades using a two directional laser velocimeter. Data presented includes radial, tangential, and cross product Reynolds stresses. Blade to blade profiles were measured at four circumferential positions and four radii within and one radius outside the four bladed impeller. The pump was tested in two configurations; with the impeller running centered within the volute, and with the impeller orbiting with a synchronous motion (ε/r2 = 0.016). Flow rates ranged from 40% to 106% of the design flow rate. Variation in profiles among the individual passages in the orbiting impeller were found. For several regions the turbulence was isotropic so that the cross product Reynolds stress was low. At low flow rates the highest cross product Reynolds stress was near the exit. At near design conditions the lowest cross product stress was near the exit, where uniform flow was also observed. Also, near the exit of the impeller the highest turbulence levels were seen near the tongue. For the design flow rate, inlet turbulence intensities were typically 9% and exit turbulence intensities were 6%. For 40% flow capacity the values increased to 18% and 19%, respectively. Large local turbulence intensities correlated with separated regions. The synchronous orbit did not increase the random turbulence, but did affect the turbulence in the individual channels in a systematic pattern.


1992 ◽  
Vol 114 (2) ◽  
pp. 350-358 ◽  
Author(s):  
R. D. Flack ◽  
S. M. Miner ◽  
R. J. Beaudoin

Turbulence profiles were measured in a centrifugal pump with an impeller with backswept blades using a two-directional laser velocimeter. Data presented include radial, tangential, and cross product Reynolds stresses. Blade-to-blade profiles were measured at four circumferential positions and four radii within and one radius outside the four-bladed impeller. The pump was tested in two configurations: with the impeller running centered within the volute, and with the impeller orbiting with a synchronous motion (ε/r2 = 0.016). Flow rates ranged from 40 to 106 percent of the design flow rate. Variation in profiles among the individual passages in the oribiting impeller were found. For several regions the turbulence was isotropic so that the cross product Reynolds stress was low. At low flow rates the highest cross product Reynolds stress was near the exit. At near-design conditions the lowest cross product stress was near the exit, where uniform flow was also observed. Also, near the exit of the impeller the highest turbulence levels were seen near the tongue. For the design flow rate, inlet turbulence intensities were typically 9 percent and exit turbulence intensities were 6 percent. For 40 percent flow capacity the values increased to 18 and 19 percent, respectively. Large local turbulence intensities correlated with separated regions. The synchronous orbit did not increase the random turbulence, but did affect the turbulence in the individual channels in a systematic pattern.


Author(s):  
Ankit Bhai Patel ◽  
K. Viswanath ◽  
Dhyanjyoti Deb Nath

Performance enhancement in terms of stall margin increment, increased pressure rise coefficient and increased efficiency is of great need for low speed axial fans. Stacking line modifications in terms of sweep, skew, dihedral or combination of these, as well as blade tip geometry modifications are assumed to be one of the ways to achieve finite performance improvement. Non radial stacking of blade profiles modifies secondary flows, tip vortex effects, hub passage vortex and thus affects aerodynamic performance parameters such as stall margin, efficiency, pressure rise, blade loading. In literature many studies have confined to comparison of few cases which led to conflicting results as modification of stacking line may have different effects in different cases. In the present work, comparison of performance of axial fan rotor with three different blade configurations BSL (baseline), SWP (swept blade) and EXTN (swept blade with extended tip) are considered. The BSL configuration is designed on basis of non-free vortex design. The SWP configuration is obtained by shifting radial stacking line of the BSL in axial flow direction by 10° (Forward sweep). The EXTN configuration is obtained by extending tip profile on pressure surface as well as suction surface by 3% locally. Experiments have been conducted on these three configurations to study effects of these modifications on aerodynamic performance. The flow field has been surveyed using Kiel probe, Three hole pressure probe at many flow rates starting from fully open to fully closed. Unsteady flow analysis at exit of rotors of all configurations is carried out using fast response pressure probe. Experimental results show slight performance improvement in terms of increased stall margin, efficiency, as well as total pressure rise for SWP rotor as well as EXTN rotor compared to BSL rotor at low flow coefficients.


1995 ◽  
Vol 117 (4) ◽  
pp. 602-608 ◽  
Author(s):  
A. Pinarbasi ◽  
M. W. Johnson

Detailed measurements have been taken of the three-dimensional velocity field within the vaneless diffuser of a backswept low speed centrifugal compressor using hot-wire anemometry. A 16 percent below and an 11 percent above design flow rate were used in the present study. Results at both flow rates show how the blade wake mixes out more rapidly than the passage wake. Strong secondary flows inherited from the impeller at the higher flow rate delay the mixing out of the circumferential velocity variations, but at both flow rates these circumferential variations are negligible at the last measurement station. The measured tangential/radial flow angle is used to recommend optimum values for the vaneless space and vane angle for design of a vaned diffuser.