scholarly journals A Comprehensive Energy and Exergoeconomic Analysis of a Novel Transcritical Refrigeration Cycle

Processes ◽  
2020 ◽  
Vol 8 (7) ◽  
pp. 758
Author(s):  
Bourhan Tashtoush ◽  
Karima Megdouli ◽  
Mouna Elakhdar ◽  
Ezzedine Nehdi ◽  
Lakdar Kairouani

A comprehensive energy and exergoeconomic analysis of a novel transcritical refrigeration cycle (NTRC) is presented. A second ejector is introduced into the conventional refrigeration system for the utilization of the gas-cooler waste heat. The thermodynamic properties of the working fluid are estimated by the database of REFPROP 9, and a FORTRAN program is used to solve the system governing equations. Exergy, energy, and exergoeconomic analyses of the two cycles are carried out to predict the exergetic destruction rate and efficiency of the systems. The optimum gas cooler working pressure will be determined for both cycles. A comprehensive comparison is made between the obtained results of the conventional and the new cycles. An enhancement of approximately 30% in the coefficient of performance (COP) of the new cycle was found in comparison to the value of the conventional cycle. In addition, the results of the analysis indicated a reduction in the overall exergy destruction rate and the total cost of the final product by 22.25% and 6%, respectively. The final product cost of the proposed NTRC was found to be 6% less than that of the conventional ejector refrigeration cycle (CERC), whereas the optimum value of the gas cooler pressure was 10.8 MPa, and 11.4 MPa for the NTRC and CERC, respectively.

Author(s):  
Waseem Raza ◽  
Gwang Soo Ko ◽  
Youn Cheol Park

The rising need for thermal comfort has resulted in a rapid increase in refrigeration systems’ usage and, subsequently, the need for electricity for air-conditioning systems. The ejector system can be driven by a free or affordable low-temperature heat source such as waste heat as the primary source of energy instead of electricity. Heat-driven ejector refrigeration systems become a promising solution for reducing energy consumption to conventional compressor-based refrigeration technologies. An air-conditioning system that uses the ejector achieves better performance in terms of energy-saving. This paper presents a study on the combined driven refrigeration cycle based on ejectors to maximize cycle performance. The experimental setup is designed to determine the coefficient of performance (COP) with ejector nozzle sizes 1.8, 3.6, and 5.4[Formula: see text]mm, respectively. In this system, the R-134a refrigerant is considered as a working fluid. The results depict that the efficiency is higher than that of the conventional refrigeration method due to comparing the performance of the conventional refrigeration cycle and the combined driven refrigeration cycle. The modified cycle efficiency is better than the vapor compression cycle below 0∘C, which implies sustainability at low temperatures by using low-grade thermal energy. For the improvement of mechanical efficiency, proposed cycle can be easily used.


Energies ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3511
Author(s):  
Ali Khalid Shaker Al-Sayyab ◽  
Joaquín Navarro-Esbrí ◽  
Victor Manuel Soto-Francés ◽  
Adrián Mota-Babiloni

This work focused on a compound PV/T waste heat driven ejector-heat pump system for simultaneous data centre cooling and waste heat recovery for district heating. The system uses PV/T waste heat as the generator’s heat source, acting with the vapour generated in an evaporative condenser as the ejector drive force. Conventional and advanced exergy and advanced exergoeconomic analyses are used to determine the cause and avoidable degree of the components’ exergy destruction rate and cost rates. Regarding the conventional exergy analysis for the whole system, the compressor represents the largest exergy destruction source of 26%. On the other hand, the generator shows the lowest sources (2%). The advanced exergy analysis indicates that 59.4% of the whole system thermodynamical inefficiencies can be avoided by further design optimisation. The compressor has the highest contribution to the destruction in the avoidable exergy destruction rate (21%), followed by the ejector (18%) and condenser (8%). Moreover, the advanced exergoeconomic results prove that 51% of the system costs are unavoidable. In system components cost comparison, the highest cost comes from the condenser, 30%. In the same context, the ejector has the lowest exergoeconomic factor, and it should be getting more attention to reduce the irreversibility by design improving. On the contrary, the evaporator has the highest exergoeconomic factor (94%).


2018 ◽  
Vol 197 ◽  
pp. 08013
Author(s):  
Enang Suma Arifianto ◽  
Ega Taqwali Berman ◽  
Mutaufiq Mutaufiq

The purpose of this research is to know the improvement of car air conditioner system performance using an ejector. The study was conducted on a car engine with power 100 PS (74 kW) @ 5000 rpm. The test procedure is carried out under two conditions: the normal refrigeration cycle mode and the refrigeration cycle mode with the ejector. The working fluid used in the refrigeration cycle is R-134a. Performance data was measured on engine revolutions ranging from 1500 - 3000 rpm. Finally, the results showed that ejector usage on AC system generates an increase in the refrigeration effect and coefficient of performance (COP) of 25% and 22%, respectively. This has implications to better cooling capacity and compressor work that is lighter.


2012 ◽  
Vol 433-440 ◽  
pp. 1219-1225
Author(s):  
Jing Hong Ning ◽  
Sheng Chun Liu

This paper reports a combined space cooling, space heating, water heating and food refrigeration system (named CO2 combined system) in supermarket. This system using CO2 as the working fluid consists of a two-stage CO2 transcritical cycle used for food refrigeration, a single-stage CO2 transcritical cycle for space cooling in summer and space heating in winter. The waste heat emitted from the CO2 gas cooling in food refrigeration cycle and space cooling and space heating cycles is recovered by heat recover exchanger and is used to provide hot water for space heating and for general usage, such as the catering, the washing and the toilet facilities in the supermarket. So this CO2 combined system improves the coefficient of performance, decreases the energy consumption as well as reduces the heat pollution. Moreover, this CO2 combined system is compared with typical conventional supermarket technology, the results show that the energy consumption of CO2 combined system is reduced largely and energy efficiency is increased obviously. It can be concluded that the CO2 combined system has a good future for protecting environment and saving energy.


Clean Energy ◽  
2021 ◽  
Vol 5 (3) ◽  
pp. 476-491
Author(s):  
Yunis Khan ◽  
Radhey Shyam Mishra

Abstract In this study, a parametric analysis was performed of a supercritical organic Rankine cycle driven by solar parabolic trough collectors (PTCs) coupled with a vapour-compression refrigeration cycle simultaneously for cooling and power production. Thermal efficiency, exergy efficiency, exergy destruction and the coefficient of performance of the cogeneration system were considered to be performance parameters. A computer program was developed in engineering equation-solver software for analysis. Influences of the PTC design parameters (solar irradiation, solar-beam incidence angle and velocity of the heat-transfer fluid in the absorber tube), turbine inlet pressure, condenser and evaporator temperature on system performance were discussed. Furthermore, the performance of the cogeneration system was also compared with and without PTCs. It was concluded that it was necessary to design the PTCs carefully in order to achieve better cogeneration performance. The highest values of exergy efficiency, thermal efficiency and exergy destruction of the cogeneration system were 92.9%, 51.13% and 1437 kW, respectively, at 0.95 kW/m2 of solar irradiation based on working fluid R227ea, but the highest coefficient of performance was found to be 2.278 on the basis of working fluid R134a. It was also obtained from the results that PTCs accounted for 76.32% of the total exergy destruction of the overall system and the cogeneration system performed well without considering solar performance.


Author(s):  
Yoon Jo Kim ◽  
Sarah Kim ◽  
Yogendra K. Joshi ◽  
Andrei G. Fedorov ◽  
Paul A. Kohl

An ionic-liquid (IL) is a salt in a liquid state usually with an organic cation and inorganic anion. ILs provide an alternative to the normally toxic working fluids in absorption systems, such as the ammonia/water system. They also eliminate the problems of poor temperature match, crystallization and metal-compatibility problems of the water/LiBr system. In the present study, an IL is explored the working fluid of a miniature absorption refrigeration system so as to utilize waste-heat within the system for low-cost, high-power electronics cooling. To determine performance benchmarks for the refrigerant/IL (e.g. [bmim][PF6]) pairs, system-level simulations have been carried out. An NRTL model was built and used to predict the solubility of the mixture as well as the mixture properties such as enthalpy and entropy. The properties of the refrigerants were determined using REFPROP 6.0. Saturation temperatures at the evaporator and condenser were 25°C and 50°C, respectively. Chip power was fixed at 100 W with the operating temperature set at 85°C. R32 gave the highest operating efficiency with the maximum coefficient of performance (COP) of ca. 0.55 while R134a and R152a showed comparable performance with the maximum COP of ca. 0.4 at the desorber outlet temperature of 80°C. When waste-heat is available for the system operation, R134a and R152a COPs were comparable or better than that of R32.


1990 ◽  
Vol 112 (3) ◽  
pp. 191-195 ◽  
Author(s):  
R. I. Loehrke

A new, completely passive, vapor compression refrigerator is described in this paper. This refrigerator combines elements of the heat pipe and the vapor jet refrigerator and is referred to here as a heat pipe refrigerator. It may be driven with heat from low temperature solar collectors or with industrial waste heat and used to provide cooling. Compression work is provided by gas dynamic processes and liquid pumping may be obtained using gravitational or capillary forces. No power is required for operation. The device has no moving parts and may be externally similar to a heat pipe with three heat transfer zones. The working fluid is chosen to match the desired operating temperature range. Water, at subatmospheric pressure, is an appropriate fluid for operation around room temperature. Theoretical considerations indicate that the thermal coefficient of performance of the heat pipe refrigerator will depend strongly on the magnitude of the temperature differences over which it is designed to operate. Results from a laboratory test confirm the concept and demonstrate cooling down to the freezing point using water vapor at 51°C to drive the device and with heat rejection at 18°C.


Entropy ◽  
2020 ◽  
Vol 22 (6) ◽  
pp. 702
Author(s):  
Bourhan Tashtoush ◽  
Tatiana Morosuk ◽  
Jigar Chudasama

Solar energy is utilized in a combined ejector refrigeration system with an organic Rankine cycle (ORC) to produce a cooling effect and generate electrical power. This study aims at increasing the utilized share of the collected solar thermal energy by inserting an ORC into the system. As the ejector refrigeration cycle reaches its maximum coefficient of performance (COP), the ORC starts working and generating electrical power. This electricity is used to run the circulating pumps and the control system, which makes the system autonomous. For the ejector refrigeration system, R134a refrigerant is selected as the working fluid for its performance characteristics and environmentally friendly nature. The COP of 0.53 was obtained for the ejector refrigeration cycle. The combined cycle of the solar ejector refrigeration and ORC is modeled in EBSILON Professional. Different parameters like generator temperature and pressure, condenser temperature and pressure, and entrainment ratio are studied, and the effect of these parameters on the cycle COP is investigated. Exergy, economic, and exergoeconomic analyses of the hybrid system are carried out to identify the thermodynamic and cost inefficiencies present in various components of the system.