scholarly journals A Non-Enzymatic Sensor Based on Fc-CHIT/CNT@Cu Nanohybrids for Electrochemical Detection of Glucose

Polymers ◽  
2020 ◽  
Vol 12 (10) ◽  
pp. 2419
Author(s):  
Fang Wang ◽  
Sheng Hu ◽  
Fengna Shi ◽  
Kexin Huang ◽  
Jiarui Li

Herein, a composite structure, consisting of Cu nanoparticles (NPs) deposited onto carbon nanotubes and modified with ferrocene-branched chitosan, was prepared in order to develop a nonenzymatic electrochemical glucose biosensor ferrocene-chitosan/carbon nanotube@ Cu (Fc-CHIT/CNT@Cu). The elemental composition of the carbon nanohybrids, morphology and structure were characterized by various techniques. Electrochemical impedance spectroscopy (EIS) was used to study the interfacial properties of the electrodes. Cyclic voltammetry (CV) and chronoamperometry methods in alkaline solution were used to determine glucose biosensing properties. The synergy effect of Cu NPs and Fc on current responses of the developed electrode resulted in good glucose sensitivity, including broad linear detection between 0.2 mM and 22 mM, a low detection limit of 13.52 μM and sensitivity of 1.256 μA mM−1cm−2. Moreover, the modified electrode possessed long-term stability and good selectivity in the presence of ascorbic acid, dopamine and uric acid. The results indicated that this inexpensive electrode had potential application for non-enzymatic electrochemical glucose detection.

2009 ◽  
Vol 25 (2) ◽  
pp. 383-387 ◽  
Author(s):  
Cheng-Teng Hsu ◽  
Hung-Chan Hsiao ◽  
Mei-Yen Fang ◽  
Jyh-Myng Zen

Micromachines ◽  
2019 ◽  
Vol 10 (4) ◽  
pp. 242 ◽  
Author(s):  
Xi ◽  
Ji ◽  
Guo ◽  
Li ◽  
Liu

Signal recording and stimulation with high spatial and temporal resolution are of increasing interest with the development of implantable brain-computer interfaces (BCIs). However, implantable BCI technology still faces challenges in the biocompatibility and long-term stability of devices after implantation. Due to the cone structure, needle electrodes have advantages in the biocompatibility and stability as nerve recording electrodes. This paper develops the fabrication of Ag needle micro/nano electrodes with a laser-assisted pulling method and modifies the electrode surface by electrochemical oxidation. A significant impedance reduction of the modified Ag/AgCl electrodes compared to the Ag electrodes is demonstrated by the electrochemical impedance spectrum (EIS). Furthermore, the stability of modified Ag/AgCl electrodes is confirmed by cyclic voltammogram (CV) scanning. These findings suggest that these micro/nano electrodes have a great application prospect in neural interfaces.


Molecules ◽  
2020 ◽  
Vol 25 (24) ◽  
pp. 5794
Author(s):  
Sumayya M. Abdulrahim ◽  
Zubair Ahmad ◽  
Jolly Bhadra ◽  
Noora Jabor Al-Thani

Despite the remarkable progress in perovskite solar cells (PSCs), their instability and rapid degradation over time still restrict their commercialization. A 2D capping layer has been proved to overcome the stability issues; however, an in-depth understanding of the complex degradation processes over a prolonged time at PSC interfaces is crucial for improving their stability. In the current work, we investigated the stability of a triple cation 3D ([(FA0.83MA0.17)Cs0.05]Pb(I0.83Br0.17)3) and 2D/3D PSC fabricated by a layer-by-layer deposition technique (PEAI-based 2D layer over triple cation 3D perovskite) using a state-of-art characterization technique: electrochemical impedance spectroscopy (EIS). A long-term stability test over 24 months was performed on the 3D and 2D/3D PSCs with an initial PCE of 18.87% and 20.21%, respectively, to suggest a more practical scenario. The current-voltage (J-V) and EIS results showed degradation in both the solar cell types; however, a slower degradation rate was observed in 2D/3D PSCs. Finally, the quantitative analysis of the key EIS parameters affected by the degradation in 3D and 2D/3D PSCs were discussed.


Sensors ◽  
2021 ◽  
Vol 21 (12) ◽  
pp. 4185
Author(s):  
Margalida Artigues ◽  
Joan Gilabert-Porres ◽  
Robert Texidó ◽  
Salvador Borrós ◽  
Jordi Abellà ◽  
...  

Bioanalytical methods, in particular electrochemical biosensors, are increasingly used in different industrial sectors due to their simplicity, low cost, and fast response. However, to be able to reliably use this type of device, it is necessary to undertake in-depth evaluation of their fundamental analytical parameters. In this work, analytical parameters of an amperometric biosensor based on covalent immobilization of glucose oxidase (GOx) were evaluated. GOx was immobilized using plasma-grafted pentafluorophenyl methacrylate (pgPFM) as an anchor onto a tailored HEMA-co-EGDA hydrogel that coats a titanium dioxide nanotubes array (TiO2NTAs). Finally, chitosan was used to protect the enzyme molecules. The biosensor offered outstanding analytical parameters: repeatability (RSD = 1.7%), reproducibility (RSD = 1.3%), accuracy (deviation = 4.8%), and robustness (RSD = 2.4%). In addition, the Ti/TiO2NTAs/ppHEMA-co-EGDA/pgPFM/GOx/Chitosan biosensor showed good long-term stability; after 20 days, it retained 89% of its initial sensitivity. Finally, glucose concentrations of different food samples were measured and compared using an official standard method (HPLC). Deviation was lower than 10% in all measured samples. Therefore, the developed biosensor can be considered to be a reliable analytical tool for quantification measurements.


Materials ◽  
2021 ◽  
Vol 14 (10) ◽  
pp. 2493
Author(s):  
Ilya I. Tumkin ◽  
Evgeniia M. Khairullina ◽  
Maxim S. Panov ◽  
Kyohei Yoshidomi ◽  
Mizue Mizoshiri

In this work, the method of selective laser reductive sintering was used to fabricate the sensor-active copper and nickel microstructures on the surface of glass-ceramics suitable for non-enzymatic detection of glucose. The calculated sensitivities for these microsensors are 1110 and 2080 μA mM−1·cm−2 for copper and nickel, respectively. Linear regime of enzymeless glucose sensing is provided between 0.003 and 3 mM for copper and between 0.01 and 3 mM for nickel. Limits of glucose detection for these manufactured micropatterns are equal to 0.91 and 2.1 µM for copper and nickel, respectively. In addition, the fabricated materials demonstrate rather good selectivity, long-term stability and reproducibility.


The Analyst ◽  
2018 ◽  
Vol 143 (24) ◽  
pp. 6025-6036 ◽  
Author(s):  
Katharina Isensee ◽  
Niklas Müller ◽  
Annemarie Pucci ◽  
Wolfgang Petrich

Anin vitroinvestigation of a quantum cascade laser-based transflection optofluidic interface for the continuous glucose monitoring in biofluids is presented with respect to its glucose sensitivity and specificity, its glucose exchange time, its resistance against temperature variations and its long-term stability.


2005 ◽  
Vol 26 (2) ◽  
pp. 100-106 ◽  
Author(s):  
James D.A. Parker ◽  
Donald H. Saklofske ◽  
Laura M. Wood ◽  
Jennifer M. Eastabrook ◽  
Robyn N. Taylor

Abstract. The concept of emotional intelligence (EI) has attracted growing interest from researchers working in various fields. The present study examined the long-term stability (32 months) of EI-related abilities over the course of a major life transition (the transition from high school to university). During the first week of full-time study, a large group of undergraduates completed the EQ-i:Short; 32 months later a random subset of these students (N = 238), who had started their postsecondary education within 24 months of graduating from high school, completed the measures for a second time. The study found EI scores to be relatively stable over the 32-month time period. EI scores were also found to be significantly higher at Time 2; the overall pattern of change in EI-levels was more than can be attributed to the increased age of the participants.


1991 ◽  
Vol 65 (03) ◽  
pp. 263-267 ◽  
Author(s):  
A M H P van den Besselaar ◽  
R M Bertina

SummaryIn a collaborative trial of eleven laboratories which was performed mainly within the framework of the European Community Bureau of Reference (BCR), a second reference material for thromboplastin, rabbit, plain, was calibrated against its predecessor RBT/79. This second reference material (coded CRM 149R) has a mean International Sensitivity Index (ISI) of 1.343 with a standard error of the mean of 0.035. The standard error of the ISI was determined by combination of the standard errors of the ISI of RBT/79 and the slope of the calibration line in this trial.The BCR reference material for thromboplastin, human, plain (coded BCT/099) was also included in this trial for assessment of the long-term stability of the relationship with RBT/79. The results indicated that this relationship has not changed over a period of 8 years. The interlaboratory variation of the slope of the relationship between CRM 149R and RBT/79 was significantly lower than the variation of the slope of the relationship between BCT/099 and RBT/79. In addition to the manual technique, a semi-automatic coagulometer according to Schnitger & Gross was used to determine prothrombin times with CRM 149R. The mean ISI of CRM 149R was not affected by replacement of the manual technique by this particular coagulometer.Two lyophilized plasmas were included in this trial. The mean slope of relationship between RBT/79 and CRM 149R based on the two lyophilized plasmas was the same as the corresponding slope based on fresh plasmas. Tlowever, the mean slope of relationship between RBT/79 and BCT/099 based on the two lyophilized plasmas was 4.9% higher than the mean slope based on fresh plasmas. Thus, the use of these lyophilized plasmas induced a small but significant bias in the slope of relationship between these thromboplastins of different species.


Sign in / Sign up

Export Citation Format

Share Document