scholarly journals Tailoring Performance, Damping, and Surface Properties of Magnetorheological Elastomers via Particle-Grafting Technology

Polymers ◽  
2018 ◽  
Vol 10 (12) ◽  
pp. 1411 ◽  
Author(s):  
Martin Cvek ◽  
Miroslav Mrlik ◽  
Jakub Sevcik ◽  
Michal Sedlacik

A novel concept based on advanced particle-grafting technology to tailor performance, damping, and surface properties of the magnetorheological elastomers (MREs) is introduced. In this work, the carbonyl iron (CI) particles grafted with poly(trimethylsilyloxyethyl methacrylate) (PHEMATMS) of two different molecular weights were prepared via surface-initiated atom transfer radical polymerization and the relations between the PHEMATMS chain lengths and the MREs properties were investigated. The results show that the magnetorheological performance and damping capability were remarkably influenced by different interaction between polydimethylsiloxane chains as a matrix and PHEMATMS grafts due to their different length. The MRE containing CI grafted with PHEMATMS of higher molecular weight exhibited a greater plasticizing effect and hence both a higher relative magnetorheological effect and enhanced damping capability were observed. Besides bulk MRE properties, the PHEMATMS modifications influenced also field-induced surface activity of the MRE sheets, which manifested as notable changes in surface roughness.

2021 ◽  
Vol 6 (4) ◽  
pp. 135-138
Author(s):  
Kofi Moro ◽  
Dorothy A. Dechie

  The Use of Froth Flotation for Selective Separation of Plastic Wastes from Soil   Kofi Moro and Dorothy A. Dechie   Abstract — In recycling of plastics, unless the goal is to form composites or materials having special properties, it is not advisable to mix plastics of different kinds because of the differences in their molecular weights and chain lengths. Hence, there is the need to separate these plastics when they are mixed before recycle can be done. This project investigated the selective separation of Polypropylene (PP), Polystyrene (PS) and Polyethylene terephthalate (PET) plastics out of soils using froth flotation. Pulverized samples were prepared from post-consumer plastic sources (PP, PS and PET) and soil and mixed uniformly to form a composite sample. The composite sample was subjected to froth flotation. Two tests were performed. A first test, where there was no addition of a depressant (tannic acid), and a second test, where there was addition of tannic acid to depress some of the plastics in order to selectively separate them. Recoveries from each test work indicated that, plastics are naturally hydrophobic and can be floated out of soils without modifying their surface properties. However, selective separations of the plastics were achieved when tannic acid was used to modify the surface properties of the plastic types.


2010 ◽  
Vol 135 ◽  
pp. 18-23 ◽  
Author(s):  
Qiu Sheng Yan ◽  
Jie Wen Yan ◽  
Jia Bin Lu ◽  
Wei Qiang Gao

A new planarization polishing method based on the cluster magnetorheological (MR) effect is presented to polish optical glass in this paper. Some process experiments were conducted to reveal the influence of the content of carbonyl iron and the abrasive materials in the MR fluid on the machining effect, and the machining characteristic of polished surface was studied. The results indicate that the surface roughness of the polished workpiece can be reduced rapidly when the strong magnetic field is applied, and ultra smooth surface with Ra 1.4 nm can be achieved while the CeO2 abrasives are used in the MR fluid. The content of carbonyl iron obviously influences the machining effect of this planarization polishing method based on cluster MR-effect. With the increase of the content of carbonyl iron in the MR fluid, the material removal rate improves and the surface roughness reduces rapidly. However, the difference of abrasive material results in various machining effects. As for the K9 optical glass, the CeO2 abrasive is better polishing abrasive than the SiC abrasive in the planarization polishing technique based on the cluster MR-effect.


2019 ◽  
Vol 31 (3) ◽  
pp. 339-348 ◽  
Author(s):  
Xincheng Song ◽  
Wenju Wang ◽  
Fufeng Yang ◽  
Guoping Wang ◽  
Xiaoting Rui

Magnetorheological elastomers are one kind of smart materials which consist of matrix materials and magnetic particles. The mechanical properties of magnetorheological elastomers were controllable under an external magnetic field. Applications of magnetorheological elastomers are limited as a result of their poor magnetorheological effect and mechanical performance, so enhancing the magnetorheological effect of them is critical for their application. Styrene-ethylene-butylene-styrene based thermoplastic elastomer was added to natural rubber to fabricate hybrid matrix–based magnetorheological elastomers. Zero modulus of magnetorheological elastomers increased from 0.50 to 0.64 MPa and magnetorheological effect increased from 28.00% to 43.75% with the addition of styrene-ethylene-butylene-styrene based thermoplastic elastomer. The contact angle of carbonyl iron particles with the matrix showed that styrene-ethylene-butylene-styrene based thermoplastic elastomer can improve the compatibility of carbonyl iron particles with the matrix. Fourier-transform infrared spectroscopy analysis has been carried out to investigate the internal structure of hybrid matrix–based magnetorheological elastomers.


1988 ◽  
Vol 60 (01) ◽  
pp. 107-112 ◽  
Author(s):  
Roy Harris ◽  
Louis Garcia Frade ◽  
Lesley J Creighton ◽  
Paul S Gascoine ◽  
Maher M Alexandroni ◽  
...  

SummaryThe catabolism of recombinant tissue plasminogen activator (rt-PA) was investigated after injection of radiolabelled material into rats. Both Iodogen and Chloramine T iodination procedures yielded similar biological activity loss in the resultant labelled rt-PA and had half lives in the rat circulation of 1 and 3 min respectively. Complex formation of rt-PA was investigated by HPLC gel exclusion (TSK G3000 SW) fractionation of rat plasma samples taken 1-2 min after 125I-rt-PA injection. A series of radiolabelled complexes of varying molecular weights were found. However, 60% of the counts were associated with a single large molecular weight complex (350–500 kDa) which was undetectable by immunologically based assays (ELISA and BIA) and showed only low activity with a functional promoter-type t-PA assay. Two major activity peaks in the HPLC fractions were associated with Tree t-PA and a complex having a molecular weight of ̴ 180 kDa. HPLC fractionation to produce these three peaks at various timed intervals after injection of 125I-rt-PA showed each to have a similar initial rate half life in the rat circulation of 4-5 min. The function of these complexes as yet is unclear but since a high proportion of rt-PA is associated with a high molecular weight complex with a short half life in the rat, we suggest that the formation of this complex may be a mechanism by which t-PA activity is initially regulated and finally cleared from the rat circulation.


1981 ◽  
Vol 45 (01) ◽  
pp. 090-094 ◽  
Author(s):  
Katsuo Sueishi ◽  
Shigeru Nanno ◽  
Kenzo Tanaka

SummaryFibrinogen degradation products were investigated for leukocyte chemotactic activity and for enhancement of vascular permeability. Both activities increased progressively with plasmin digestion of fibrinogen. Active fragments were partially purified from 24 hr-plasmin digests. Molecular weights of the permeability increasing and chemotactic activity fractions were 25,000-15,000 and 25,000 respectively. Both fractions had much higher activities than the fragment X, Y, D or E. Electron microscopic observation of the small blood vessels in rabbit skin correlated increased permeability with the formation of characteristic gaps between adjoining endothelial cells and their contraction.These findings suggest that lower molecular weight degradation products of fibrinogen may be influential in contributing to granulocytic infiltration and enhanced permeability in lesions characterized by deposits of fibrin and/or fibrinogen.


1964 ◽  
Vol 12 (01) ◽  
pp. 232-261 ◽  
Author(s):  
S Sasaki ◽  
T Takemoto ◽  
S Oka

SummaryTo demonstrate whether the intravascular precipitation of fibrinogen is responsible for the toxicity of heparinoid, the relation between the toxicity of heparinoid in vivo and the precipitation of fibrinogen in vitro was investigated, using dextran sulfate of various molecular weights and various heparinoids.1. There are close relationships between the molecular weight of dextran sulfate, its toxicity, and the quantity of fibrinogen precipitated.2. The close relationship between the toxicity and the precipitation of fibrinogen found for dextran sulfate holds good for other heparinoids regardless of their molecular structures.3. Histological findings suggest strongly that the pathological changes produced with dextran sulfate are caused primarily by the intravascular precipitates with occlusion of the capillaries.From these facts, it is concluded that the precipitates of fibrinogen with heparinoid may be the cause or at least the major cause of the toxicity of heparinoid.4. The most suitable molecular weight of dextran sulfate for clinical use was found to be 5,300 ~ 6,700, from the maximum value of the product (LD50 · Anticoagulant activity). This product (LD50 · Anticoagulant activity) can be employed generally to assess the comparative merits of various heparinoids.5. Clinical use of the dextran sulfate prepared on this basis gave satisfactory results. No severe reaction was observed. However, two delayed reactions, alopecia and thrombocytopenia, were observed. These two reactions seem to come from the cause other than intravascular precipitation.


1962 ◽  
Vol 08 (02) ◽  
pp. 270-275 ◽  
Author(s):  
David L Aronson ◽  
John W Preiss ◽  
Michael W Mosesson

SummaryThe molecular weights of AHF (factor VIII) and of PTC (factor IX) have been estimated by their sensitivity to inactivation by 7 kilovolt electrons. The molecular weight of AHF was found to be 180 000 by this method and that of PTC was found to be 110 000.


2015 ◽  
Vol 1718 ◽  
pp. 97-102 ◽  
Author(s):  
Toralf Roch ◽  
Konstanze K. Julich-Gruner ◽  
Axel T. Neffe ◽  
Nan Ma ◽  
Andreas Lendlein

ABSTRACTPolymer-based therapeutic strategies require biomaterials with properties and functions tailored to the demands of specific applications leading to an increasing number of newly designed polymers. For the evaluation of those new materials, comprehensive biocompatibility studies including cyto-, tissue-, and immunocompatibility are essential. Recently, it could be demonstrated that star-shaped amino oligo(ethylene glycol)s (sOEG) with a number average molecular weight of 5 kDa and functionalized with the phenol-derived moieties desaminotyrosine (DAT) or desaminotyrosyl tyrosine (DATT) behave in aqueous solution like surfactants without inducing a substantial cytotoxicity, which may qualify them as solubilizer for hydrophobic drugs in aqueous solution. However, for biomedical applications the polymer solutions need to be free of immunogenic contaminations, which could result from inadequate laboratory environment or contaminated starting material. Furthermore, the materials should not induce uncontrolled or undesired immunological effects arising from material intrinsic properties. Therefore, a comprehensive immunological evaluation as perquisite for application of each biomaterial batch is required. This study investigated the immunological properties of sOEG-DAT(T) solutions, which were prepared using sOEG with number average molecular weights of 5 kDa, 10 kDa, and 20 kDa allowing analyzing the influence of the sOEG chain lengths on innate immune mechanisms. A macrophage-based assay was used to first demonstrate that all DAT(T)-sOEG solutions are free of endotoxins and other microbial contaminations such as fungal products. In the next step, the capacity of the different DAT(T)-functionalized sOEG solutions to induce cytokine secretion and generation of reactive oxygen species (ROS) was investigated using whole human blood. It was observed that low levels of the pro-inflammatory cytokines interleukin(IL)-1β and IL-6 were detected for all sOEG solutions but only when used at concentrations above 250 µg·mL-1. Furthermore, only the 20 kDa sOEG-DAT induced low amounts of ROS-producing monocytes. Conclusively, the data indicate that the materials were not contaminated with microbial products and do not induce substantial immunological adverse effectsin vitro,which is a prerequisite for future biological applications.


RSC Advances ◽  
2021 ◽  
Vol 11 (21) ◽  
pp. 12641-12648
Author(s):  
Renyuan Chen ◽  
Caidie Xu ◽  
Yihao Lei ◽  
Hongxin Liu ◽  
Yabin Zhu ◽  
...  

A family of low molecular weight gelators with different alkyl chain lengths was constructed, having excellent gelation ability and antibiotic loading capacity. A low molecular weight hydrogelator was obtained by adjusting the length of alkyl chain.


Micromachines ◽  
2021 ◽  
Vol 12 (7) ◽  
pp. 843
Author(s):  
Woo Jin Jeong ◽  
Jong Ik Lee ◽  
Hee Jung Kwak ◽  
Jae Min Jeon ◽  
Dong Yeol Shin ◽  
...  

We investigated the performance of single-structured light-emitting electrochemical cell (LEC) devices with Ru(bpy)3(PF6)2 polymer composite as an emission layer by controlling thickness and heat treatment. When the thickness was smaller than 120–150 nm, the device performance decreased because of the low optical properties and non-dense surface properties. On the other hand, when the thickness was over than 150 nm, the device had too high surface roughness, resulting in high-efficiency roll-off and poor device stability. With 150 nm thickness, the absorbance increased, and the surface roughness was low and dense, resulting in increased device characteristics and better stability. The heat treatment effect further improved the surface properties, thus improving the device characteristics. In particular, the external quantum efficiency (EQE) reduction rate was shallow at 100 °C, which indicates that the LEC device has stable operating characteristics. The LEC device exhibited a maximum luminance of 3532 cd/m2 and an EQE of 1.14% under 150 nm thickness and 100 °C heat treatment.


Sign in / Sign up

Export Citation Format

Share Document