scholarly journals Comparison of Inductively Coupled Plasma Optical Emission Spectrometry with an Ion Selective Electrode to Determine Sodium and Potassium Levels in Human Milk

Nutrients ◽  
2018 ◽  
Vol 10 (9) ◽  
pp. 1218 ◽  
Author(s):  
Ching Lai ◽  
Hazel Gardner ◽  
Donna Geddes

Sodium (Na), potassium (K), and the ratio Na:K in human milk (HM) may be useful biomarkers to indicate secretory activation or inflammation in the breast. Previously, these elements have been measured in a laboratory setting requiring expensive equipment and relatively large amounts of HM. The aim of this study was to compare measurements of Na and K in HM using inductively coupled plasma optical emission spectrometry (ICP-OES) with small portable ion selective electrode probes for Na and K. Sixty-five lactating women donated 5 mL samples of HM. Samples were analyzed with two ion selective probes (Na and K) and also ICP-OES. The data were analyzed using paired t-test and Bland–Altman plots. Na concentrations were not significantly different when measured with ion selective electrode (6.18 ± 2.47mM; range: 3.59–19.8) and ICP-OES (5.91 ± 3.37 mM; range: 2.59–21.5) (p = 0.20). K concentrations measured using the ion selective electrode (11.7 ± 2.21 mM: range: 7.69–18.1) and ICP-OES (11.1 ± 1.55 mM: range: 7.91–15.2) were significantly different (p = 0.01). However, the mean differences of 0.65 mM would not be clinically relevant when testing at point of care. Compared to ICP-OES, ion selective electrode is sufficiently accurate to detect changes in concentrations of Na and K in HM associated with secretory activation and inflammation in the mammary gland.

Author(s):  
Masoud Aghahoseini ◽  
Gholamhassan Azimi ◽  
M. K. Amini

Determination of traces of Cd, Co, Cu, Mn and Pb elements in zirconium and its alloys by inductively coupled plasma optical emission spectrometry (ICP OES) suffers from severe spectral interferences...


2014 ◽  
Vol 97 (3) ◽  
pp. 687-699 ◽  
Author(s):  
James M Bartos ◽  
Barton L Boggs ◽  
J Harold Falls ◽  
Sanford A Siegel

Abstract A two-part single-laboratory validation study was conducted for determination of the P and K content in commercial fertilizer materials by inductively coupled plasma-optical emission spectrometry (ICP- OES). While several methods exist for determination of P and K in fertilizer products, the main focus of this study was on ICP-OES determination, which offers several unique advantages. Fertilizer samples with consensus P and K values from the Magruder and Association of Fertilizer and Phosphate Chemists (AFPC) check sample programs were selected for this study. Validation materials ranging from 4.4 to 52.4% P2O5 (1.7 to 22.7% P) and 3 to 62% K2O (2.5 to 51.5% K) were utilized. Because all P and K compounds contained in fertilizer materials are not "available" for plants to use, this study was conducted in two parts. Part A focused on ammonium citrate–disodium EDTA as the extraction solvent, as it estimates the pool of fertilizer P and K that is considered available to plants. Part B focused on hydrochloric acid as the digestion solvent, as it estimates the total P and K content of the fertilizer product. Selectivity studies indicated that this method can have a high bias for fertilizer products containing sources of phosphite or organic P compared to gravimetric or colorimetric methods that measure just orthophosphate. Provided the analytical challenges outlined in this study are addressed, this method offers the potential for a quick, accurate, and safe alternative for determining the P and K content of commercial inorganic fertilizer materials.