scholarly journals The Scopoletin-HRP Fluorimetric Determination of H2O2 in Seawaters—A Plea for the Two-Stage Protocol

2017 ◽  
Vol 1 (1) ◽  
pp. 4 ◽  
Author(s):  
Man Wu ◽  
George Wong ◽  
Yao-Chu Wu
1970 ◽  
Vol 23 (02) ◽  
pp. 191-201 ◽  
Author(s):  
H. D Bruhn ◽  
L Müller ◽  
F Duckert

SummaryA modification of the caseinolytic assay for plasminogen is described. This assay system is characterized by the following features :1. Urokinase is used as activator achieving a complete activation of the plasminogen whereas with streptokinase caseinolytically inactive plasminogen-activator complexes are formed.2. All incubation times are reduced to the minimum which is still compatible with accuracy.3. Results are expressed in percent of a standard of ten normal plasmas.4. In this two-stage assay-system (activation of plasminogen to plasmin, digestion of casein by plasmin) both stages proceed simultaneously in the same system, thus the plasmin formed is stabilized “in statu nascendi” by the casein.5. Several conditions (stability of plasminogen in frozen plasma, use of anticoagulants, reproducibility) are defined.


1967 ◽  
Vol 18 (01/02) ◽  
pp. 198-210 ◽  
Author(s):  
Ronald S Reno ◽  
Walter H Seegers

SummaryA two-stage assay procedure was developed for the determination of the autoprothrombin C titre which can be developed from prothrombin or autoprothrombin III containing solutions. The proenzyme is activated by Russell’s viper venom and the autoprothrombin C activity that appears is measured by its ability to shorten the partial thromboplastin time of bovine plasma.Using the assay, the autoprothrombin C titre was determined in the plasma of several species, as well as the percentage of it remaining in the serum from blood clotted in glass test tubes. Much autoprothrombin III remains in human serum. With sufficient thromboplastin it was completely utilized. Plasma from selected patients with coagulation disorders was assayed and only Stuart plasma was abnormal. In so-called factor VII, IX, and P.T.A. deficiency the autoprothrombin C titre and thrombin titre that could be developed was normal. In one case (prethrombin irregularity) practically no thrombin titre developed but the amount of autoprothrombin C which generated was in the normal range.Dogs were treated with Dicumarol and the autoprothrombin C titre that could be developed from their plasmas decreased until only traces could be detected. This coincided with a lowering of the thrombin titre that could be developed and a prolongation of the one-stage prothrombin time. While the Dicumarol was acting, the dogs were given an infusion of purified bovine prothrombin and the levels of autoprothrombin C, thrombin and one-stage prothrombin time were followed for several hours. The tests became normal immediately after the infusion and then went back to preinfusion levels over a period of 24 hrs.In other dogs the effect of Dicumarol was reversed by giving vitamin K1 intravenously. The effect of the vitamin was noticed as early as 20 min after administration.In response to vitamin K the most pronounced increase was with that portion of the prothrombin molecule which yields thrombin. The proportion of that protein with respect to the precursor of autoprothrombin C increased during the first hour and then started to go down and after 3 hrs was equal to the proportion normally found in plasma.


1989 ◽  
Vol 54 (3) ◽  
pp. 616-621 ◽  
Author(s):  
Záviš Holzbecher

It has been found that phosphoric acid decreases the first excitation maximum of Ce(III) at 256 nm, increases the second excitation maximum at 297 nm and shifts the fluorescence maximum from 350 to 346 nm. Under optimum conditions, with λexc = 297 nm and λem = 346 nm, Ce(III) can be determined fluorimetrically with a detection limit of 1.2 ng ml-1 in 12M-H3PO4 medium. No interference was observed from a 20-200 fold excess of HCl, H2SO4, Na, K, NH4+, Al and the rare earth elements. HNO3 interferes and Ce(IV) and Fe(III) interfere strongly. It follows from the stereofluorograms of Ce and Tb that the spectra of the two elements are practically independent. The detection limit for Tb(III) in 0.02-2.5M-H2SO4 medium for λexc = 222 nm and λem = 494 nm is 33 ng ml-1. No interference was observed from a 5-20 fold excess of Al3+ and the other rare earth elements. The determination is slightly less sensitive in H3PO4 or HCl medium. The relative standard deviation of the measurement for 10 ng ml-1 Ce(III) or 50 ng ml-1 Tb(III) is about 3%.


Author(s):  
Richard Adelstein

This chapter elaborates the operation of criminal liability by closely considering efficient crimes and the law’s stance toward them, shows how its commitment to proportional punishment prevents the probability scaling that systemically efficient allocation requires, and discusses the procedures that determine the actual liability prices imposed on offenders. Efficient crimes are effectively encouraged by proportional punishment, and their nature and implications are examined. But proportional punishment precludes probability scaling, and induces far more than the systemically efficient number of crimes. Liability prices that match the specific costs imposed by the offender at bar are sought through a two-stage procedure of legislative determination of punishment ranges ex ante and judicial determination of exact prices ex post, which creates a dilemma: whether to price crimes accurately in the past or deter them accurately in the future. An illustrative Supreme Court case bringing all these themes together is discussed in conclusion.


1994 ◽  
Vol 27 (5) ◽  
pp. 867-878 ◽  
Author(s):  
D. W. Bryce ◽  
J. M. Fernández-Romero ◽  
M. D. Luque de Castro

The Analyst ◽  
1985 ◽  
Vol 110 (1) ◽  
pp. 43-45 ◽  
Author(s):  
Soledad Rubio ◽  
Agustina Gómez-Hens ◽  
Miguel Valcárcel

Sign in / Sign up

Export Citation Format

Share Document