scholarly journals Chemical Separation of Uranium and Precise Measurement of 234U/238U and 235U/238U Ratios in Soil Samples Using Multi Collector Inductively Coupled Plasma Mass Spectrometry

Molecules ◽  
2020 ◽  
Vol 25 (9) ◽  
pp. 2138 ◽  
Author(s):  
Nimelan Veerasamy ◽  
Asako Takamasa ◽  
Rajamanickam Murugan ◽  
Sharayu Kasar ◽  
Tatsuo Aono ◽  
...  

A new chemical separation has been developed to isolate uranium (U) using two UTEVA columns to minimize iron and thorium interferences from high background area soil samples containing minerals like monazites and ilmenite. The separation method was successfully verified in some certified reference materials (CRMs), for example, JSd-2, JLk-1, JB-1 and JB-3. The same method was applied for purification of U in Fukushima soil samples affected by the Fukushima dai-ichi nuclear power station (FDNPS) accident. Precise and accurate measurement of 234U/238U and 235U/238U isotope ratios in chemically separated U were carried out using a multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS). In this mass spectrometric method, an array of two Faraday cups (1011 Ω, 1012 Ω resistor) and a Daly detector were simultaneously employed. The precision of U isotope ratios in an in-house standard was evaluated by replicate measurement. Relative standard deviation (RSD) of 234U/238U and 235U/238U were found to be 0.094% (2σ) and 0.590% (2σ), respectively. This method has been validated using a standard reference material SRM 4350B, sediment sample. The replicate measurements of 234U/238U in SRM shows 0.7% (RSD). This developed method is suitable for separation of U and its isotope ratio measurement in environmental samples.

1998 ◽  
Vol 44 (4) ◽  
pp. 817-824 ◽  
Author(s):  
Max Haldimann ◽  
Bernhard Zimmerli ◽  
Claudine Als ◽  
Hans Gerber

Abstract An inductively coupled mass spectrometric method was developed for the direct determination of iodine in urine. The application of isotope dilution analysis with added 129I offers new possibilities for automatic and accurate determinations. The sample preparation consists of dilution with an ammonia solution containing 129I. The validation was made by comparison with the results obtained in another laboratory by a spectrophotometric method based on the Sandell–Kolthoff reaction. Different regression models, including maximum likelihood estimation, were used to compare the methods. None of the models revealed analytical bias between the two methods. The urine samples analyzed for validation were from three persons previously exposed to an iodine bath and covered a concentration range of 0.2 to 2.8 μmol/L. A detection limit of 0.02 μmol/L, a within-run CV of 2.5%, and a between-run CV of 11.9% were estimated for the proposed method.


2021 ◽  
Author(s):  
◽  
John Creech

<p>A wide range of novel, non-traditional, stable isotope systems have been developed over the last decade, largely as a result of the advent of multiple-collector inductively coupled plasma mass spectrometry (MC-ICPMS), and continue to provide valuable new insights in the earth, environmental and planetary sciences. The platinum (Pt) stable isotope system represents a potentially powerful but, as yet, unexplored addition to this suite of stable isotope tracers. Pt has six naturally occurring isotopes, and can exist in a range of oxidation states. The geochemical behaviour of Pt coupled with the relatively large mass difference (ca. 2%) between the abundant heavy and light isotopes and its variable oxidation states leads to potential applications in tracing a range of natural processes. In particular, the strong elemental partitioning of Pt between metals and silicates makes the Pt stable isotope system uniquely suited to tracing processes of Earth’s accretion and differentiation. This study aims to develop new techniques for measurement of Pt stable isotopes in geological samples, and to apply these to terrestrial and meteorite samples to attempt to resolve outstanding questions relating to Earth’s early evolution.  A technique was developed for measurement of Pt stable isotope ratios using multiple collector inductively coupled plasma mass spectrometry (MCICPMS), employing a ¹⁹⁶Pt–¹⁹⁸Pt double-spike to correct for instrumental mass fractionation. Results are reported in terms of δ¹⁹⁸Pt, which represents the per mil difference in the ¹⁹⁸Pt/¹⁹⁴Pt ratio from the IRMM-010 Pt isotope standard. A range of analytical tests were conducted and show that this approach has a reproducibility of ca. ±0.04 %∘ on δ¹⁹⁸Pt (i.e., ±0.01%∘ amu⁻¹) for Pt solution standards, and is insensitive to minor amounts of matrix that may be retained after chemical purification of Pt. Measurements of Pt solution standards conducted using two different MC-ICPMS instruments showed resolvable variations, which suggest that natural fractionations exist that exceed the reproducibility of the technique.  Techniques were also developed for dissolution of natural samples and chemical separation of Pt. Geological standards were digested using a nickel sulphide fire assay technique, which pre-concentrates the highly siderophile elements in a NiS bead that is readily dissolved in acid. This was followed by chemical separation of Pt from digested samples using anion exchange chemical techniques. Elution curves were constructed for a range of synthetic rock matrices. These tests show that Pt separation is achieved with >90% Pt yield and ca. 95% purity. Analytical tests show that this level of Pt separation is sufficient for accurate determination of Pt stable isotope ratios by double-spike MC-ICPMS. These techniques were then applied to 11 international geological standard reference materials representing mantle peridotites, igneous samples, and Pt ore materials. The reproducibility in natural samples was determined by processing multiple replicate digestions of a standard reference material, and was shown to be ca. ±0.08%∘ (2 sd). Pt stable isotope data for the full set of reference materials have a range of δ¹⁹⁸Pt values with offsets of up to 0.40%∘ from the IRMM-010 standard, which are readily resolved with this technique. Mantle samples yielded the lightest (most negative) isotopic compositions of the terrestrial standards, with igneous and Pt ore samples defining a continuous trend towards zero, which is consistent with the IRMM-010 standard being derived from a Pt ore. These results demonstrate the potential of the Pt isotope system as a tracer in geochemical systems.  The techniques developed above were then applied to investigate an outstanding problem relating to Earth’s accretion and differentiation. Highly siderophile elements (HSE) are strongly partitioned into the cores of terrestrial planets during core formation, and the abundances of HSE in Earth’s mantle compared with primitive meteorites have provided key constraints on models of Earth’s early evolution. Two leading models to explain the HSE abundances in the silicate Earth involve either a late-veneer of chondritic material that was added after core formation or core formation in a deep magma ocean. The platinum (Pt) stable isotope system represents a novel tool for investigating these processes. Using the techniques developed above, Pt stable isotope ratios were measured in a range of meteorite samples, including enstatite, ordinary and carbonaceous chondrites, primitive achondrites, achondrites and iron meteorites, as well as additional terrestrial mantle xenolith samples. Our data set reveals that the Pt stable isotopic composition of Earth’s mantle overlaps with all of the chondrite groups. Primitive achondrite and ureilite samples revealed the heaviest compositions of all meteorite groups. These data suggest that metal–silicate differentiation produces an isotopic fractionation for Pt, with heavy isotopes being preferentially retained in the silicate phase. Thus, Earth’s mantle is expected to have been significantly enriched in the heavy isotopes of Pt during core formation, even if metal–silicate differentiation took place in a magma ocean. The absence of a large fractionation between chondrites, representing the composition of the undifferentiated Earth, and the mantle suggests that the signature of core formation in the mantle has been subsequently overprinted. Considering the overlap between the Pt stable isotopic compositions of the mantle and chondrites, the most likely means for overprinting the composition of the mantle is by addition of a chondritic late-veneer. Mixing calculations show that addition of 0.5% of Earth’s mass by a late-veneer of chondritic material would be sufficient to overprint highly fractionated Pt stable isotope signatures resulting from core-formation.</p>


1994 ◽  
Vol 48 (11) ◽  
pp. 1360-1366 ◽  
Author(s):  
Arnold R. Warren ◽  
Lloyd A. Allen ◽  
Ho-Ming Pang ◽  
R. S. Houk ◽  
Morteza Janghorbani

The ion beam from the inductively coupled plasma (ICP) is split into two parts by a device comprised of two electrostatic analyzers in a back-to-back arrangement. Each ion beam is then monitored by a separate quadrupole mass analyzer and electron multiplier. Thus, ion ratios can be measured simultaneously without scanning. Isotope ratios for copper are measured with a precision of 0.14% relative standard deviation (RSD). Internal standard ratios for Co+/La+ are measured with a precision of 1% RSD. Ion signals in the two channels are highly correlated, and the magnitude of flicker noise is reduced in the resulting ratios. Bias in the measured isotope ratios is substantial but can be corrected by calibration.


2021 ◽  
Author(s):  
◽  
John Creech

<p>A wide range of novel, non-traditional, stable isotope systems have been developed over the last decade, largely as a result of the advent of multiple-collector inductively coupled plasma mass spectrometry (MC-ICPMS), and continue to provide valuable new insights in the earth, environmental and planetary sciences. The platinum (Pt) stable isotope system represents a potentially powerful but, as yet, unexplored addition to this suite of stable isotope tracers. Pt has six naturally occurring isotopes, and can exist in a range of oxidation states. The geochemical behaviour of Pt coupled with the relatively large mass difference (ca. 2%) between the abundant heavy and light isotopes and its variable oxidation states leads to potential applications in tracing a range of natural processes. In particular, the strong elemental partitioning of Pt between metals and silicates makes the Pt stable isotope system uniquely suited to tracing processes of Earth’s accretion and differentiation. This study aims to develop new techniques for measurement of Pt stable isotopes in geological samples, and to apply these to terrestrial and meteorite samples to attempt to resolve outstanding questions relating to Earth’s early evolution.  A technique was developed for measurement of Pt stable isotope ratios using multiple collector inductively coupled plasma mass spectrometry (MCICPMS), employing a ¹⁹⁶Pt–¹⁹⁸Pt double-spike to correct for instrumental mass fractionation. Results are reported in terms of δ¹⁹⁸Pt, which represents the per mil difference in the ¹⁹⁸Pt/¹⁹⁴Pt ratio from the IRMM-010 Pt isotope standard. A range of analytical tests were conducted and show that this approach has a reproducibility of ca. ±0.04 %∘ on δ¹⁹⁸Pt (i.e., ±0.01%∘ amu⁻¹) for Pt solution standards, and is insensitive to minor amounts of matrix that may be retained after chemical purification of Pt. Measurements of Pt solution standards conducted using two different MC-ICPMS instruments showed resolvable variations, which suggest that natural fractionations exist that exceed the reproducibility of the technique.  Techniques were also developed for dissolution of natural samples and chemical separation of Pt. Geological standards were digested using a nickel sulphide fire assay technique, which pre-concentrates the highly siderophile elements in a NiS bead that is readily dissolved in acid. This was followed by chemical separation of Pt from digested samples using anion exchange chemical techniques. Elution curves were constructed for a range of synthetic rock matrices. These tests show that Pt separation is achieved with >90% Pt yield and ca. 95% purity. Analytical tests show that this level of Pt separation is sufficient for accurate determination of Pt stable isotope ratios by double-spike MC-ICPMS. These techniques were then applied to 11 international geological standard reference materials representing mantle peridotites, igneous samples, and Pt ore materials. The reproducibility in natural samples was determined by processing multiple replicate digestions of a standard reference material, and was shown to be ca. ±0.08%∘ (2 sd). Pt stable isotope data for the full set of reference materials have a range of δ¹⁹⁸Pt values with offsets of up to 0.40%∘ from the IRMM-010 standard, which are readily resolved with this technique. Mantle samples yielded the lightest (most negative) isotopic compositions of the terrestrial standards, with igneous and Pt ore samples defining a continuous trend towards zero, which is consistent with the IRMM-010 standard being derived from a Pt ore. These results demonstrate the potential of the Pt isotope system as a tracer in geochemical systems.  The techniques developed above were then applied to investigate an outstanding problem relating to Earth’s accretion and differentiation. Highly siderophile elements (HSE) are strongly partitioned into the cores of terrestrial planets during core formation, and the abundances of HSE in Earth’s mantle compared with primitive meteorites have provided key constraints on models of Earth’s early evolution. Two leading models to explain the HSE abundances in the silicate Earth involve either a late-veneer of chondritic material that was added after core formation or core formation in a deep magma ocean. The platinum (Pt) stable isotope system represents a novel tool for investigating these processes. Using the techniques developed above, Pt stable isotope ratios were measured in a range of meteorite samples, including enstatite, ordinary and carbonaceous chondrites, primitive achondrites, achondrites and iron meteorites, as well as additional terrestrial mantle xenolith samples. Our data set reveals that the Pt stable isotopic composition of Earth’s mantle overlaps with all of the chondrite groups. Primitive achondrite and ureilite samples revealed the heaviest compositions of all meteorite groups. These data suggest that metal–silicate differentiation produces an isotopic fractionation for Pt, with heavy isotopes being preferentially retained in the silicate phase. Thus, Earth’s mantle is expected to have been significantly enriched in the heavy isotopes of Pt during core formation, even if metal–silicate differentiation took place in a magma ocean. The absence of a large fractionation between chondrites, representing the composition of the undifferentiated Earth, and the mantle suggests that the signature of core formation in the mantle has been subsequently overprinted. Considering the overlap between the Pt stable isotopic compositions of the mantle and chondrites, the most likely means for overprinting the composition of the mantle is by addition of a chondritic late-veneer. Mixing calculations show that addition of 0.5% of Earth’s mass by a late-veneer of chondritic material would be sufficient to overprint highly fractionated Pt stable isotope signatures resulting from core-formation.</p>


1985 ◽  
Vol 39 (3) ◽  
pp. 535-541 ◽  
Author(s):  
J. R. Garbarino ◽  
B. E. Jones ◽  
G. P. Stein ◽  
W. T. Belser ◽  
H. E. Taylor

In an interlaboratory test, inductively coupled plasma atomic emission spectrometry (ICP-AES) was compared with flame atomic absorption spectrometry and molecular absorption spectrophotometry for the determination of 17 major and trace elements in 100 filtered natural water samples. No unacceptable biases were detected. The analysis precision of ICP-AES was found to be equal to or better than alternative methods. Known-addition recovery experiments demonstrated that the ICP-AES determinations are accurate to between ±2 and ±10 percent; four-fifths of the tests yielded average recoveries of 95–105 percent, with an average relative standard deviation of about 5 percent.


Sign in / Sign up