scholarly journals PLS Subspace-Based Calibration Transfer for Near-Infrared Spectroscopy Quantitative Analysis

Molecules ◽  
2019 ◽  
Vol 24 (7) ◽  
pp. 1289 ◽  
Author(s):  
Yuhui Zhao ◽  
Jinlong Yu ◽  
Peng Shan ◽  
Ziheng Zhao ◽  
Xueying Jiang ◽  
...  

In order to enable the calibration model to be effectively transferred among multiple instruments and correct the differences between the spectra measured by different instruments, a new feature transfer model based on partial least squares regression (PLS) subspace (PLSCT) is proposed in this paper. Firstly, the PLS model of the master instrument is built, meanwhile a PLS subspace is constructed by the feature vectors. Then the master spectra and the slave spectra are projected into the PLS subspace, and the features of the spectra are also extracted at the same time. In the subspace, the pseudo predicted feature of the slave spectra is transferred by the ordinary least squares method so that it matches the predicted feature of the master spectra. Finally, a feature transfer relationship model is constructed through the feature transfer of the PLS subspace. This PLS-based subspace transfer provides an efficient method for performing calibration transfer with only a small number of standard samples. The performance of the PLSCT was compared and assessed with slope and bias correction (SBC), piecewise direct standardization (PDS), calibration transfer method based on canonical correlation analysis (CCACT), generalized least squares (GLSW), multiplicative signal correction (MSC) methods in three real datasets, statistically tested by the Wilcoxon signed rank test. The obtained experimental results indicate that PLSCT method based on the PLS subspace is more stable and can acquire more accurate prediction results.

2019 ◽  
Vol 5 (1) ◽  
pp. 10 ◽  
Author(s):  
Ahmed Rady ◽  
Daniel Guyer ◽  
William Kirk ◽  
Irwin R Donis-González

The sprouting of potato tubers during storage is a significant problem that suppresses obtaining high quality seeds or fried products. In this study, the potential of fusing data obtained from visible (VIS)/near-infrared (NIR) spectroscopic and hyperspectral imaging systems was investigated, to improve the prediction of primordial leaf count as a significant sign for tubers sprouting. Electronic and lab measurements were conducted on whole tubers of Frito Lay 1879 (FL1879) and Russet Norkotah (R.Norkotah) potato cultivars. The interval partial least squares (IPLS) technique was adopted to extract the most effective wavelengths for both systems. Linear regression was utilized using partial least squares regression (PLSR), and the best calibration model was chosen using four-fold cross-validation. Then the prediction models were obtained using separate test data sets. Prediction results were enhanced compared with those obtained from individual systems’ models. The values of the correlation coefficient (the ratio between performance to deviation, or r(RPD)) were 0.95(3.01) and 0.9s6(3.55) for FL1879 and R.Norkotah, respectively, which represented a feasible improvement by 6.7%(35.6%) and 24.7%(136.7%) for FL1879 and R.Norkotah, respectively. The proposed study shows the possibility of building a rapid, noninvasive, and accurate system or device that requires minimal or no sample preparation to track the sprouting activity of stored potato tubers.


2020 ◽  
Vol 38 (No. 2) ◽  
pp. 131-136
Author(s):  
Wojciech Poćwiardowski ◽  
Joanna Szulc ◽  
Grażyna Gozdecka

The aim of the study was to elaborate a universal calibration for the near infrared (NIR) spectrophotometer to determine the moisture of various kinds of vegetable seeds. The research was conducted on the seeds of 5 types of vegetables – carrot, parsley, lettuce, radish and beetroot. For the spectra correlation with moisture values, the method of partial least squares regression (PLS) was used. The resulting qualitative indicators of a calibration model (R = 0.9968, Q = 0.8904) confirmed an excellent fit of the obtained calibration to the experimental data. As a result of the study, the possibilities of creating a calibration model for NIR spectrophotometer for non-destructive moisture analysis of various kinds of vegetable seeds was confirmed.<br /><br />


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Sung-Wook Hwang ◽  
Un Taek Hwang ◽  
Kyeyoung Jo ◽  
Taekyeong Lee ◽  
Jinseok Park ◽  
...  

AbstractThe aim of this study is to establish prediction models for the non-destructive evaluation of the carbonization characteristics of lignin-derived hydrochars as a carbon material in real time. Hydrochars are produced via the hydrothermal carbonization of kraft lignins for 1–5 h in the temperature range of 175–250 °C, and as the reaction severity of hydrothermal carbonization increases, the hydrochar is converted to a more carbon-intensive structure. Principal component analysis using near-infrared spectra suggests that the spectral regions at 2132 and 2267 nm assigned to lignins and 1449 nm assigned to phenolic groups of lignins are informative bands that indicate the carbonization degree. Partial least squares regression models trained with near-infrared spectra accurately predicts the carbon content, oxygen/carbon, and hydrogen/carbon ratios with high coefficients of determination and low root mean square errors. The established models demonstrate better prediction than ordinary least squares regression models.


Molecules ◽  
2019 ◽  
Vol 24 (9) ◽  
pp. 1802 ◽  
Author(s):  
Yuhui Zhao ◽  
Ziheng Zhao ◽  
Peng Shan ◽  
Silong Peng ◽  
Jinlong Yu ◽  
...  

Calibration transfer is an important field for near-infrared (NIR) spectroscopy in practical applications. However, most transfer methods are constructed with standard samples, which are expensive and difficult to obtain. Taking this problem into account, this paper proposes a calibration transfer method based on affine invariance without transfer standards (CTAI). Our method can be utilized to adjust the difference between two instruments by affine transformation. CTAI firstly establishes a partial least squares (PLS) model of the master instrument to obtain score matrices and predicted values of the two instruments, and then the regression coefficients between each of the score vectors and predicted values are computed for the master instrument and the slave instrument, respectively. Next, angles and biases are calculated between the regression coefficients of the master instrument and the corresponding regression coefficients of the slave instrument, respectively. Finally, by introducing affine transformation, new samples are predicted based on the obtained angles and biases. A comparative study between CTAI and the other five methods was conducted, and the performances of these algorithms were tested with two NIR spectral datasets. The obtained experimental results show clearly that, in general CTAI is more robust and can also achieve the best Root Mean Square Error of test sets (RMSEPs). In addition, the results of statistical difference with the Wilcoxon signed rank test show that CTAI is generally better than the others, and at least statistically the same.


2007 ◽  
Vol 61 (7) ◽  
pp. 747-754 ◽  
Author(s):  
Robert D. Guenard ◽  
Christine M. Wehlburg ◽  
Randy J. Pell ◽  
David M. Haaland

This paper reports on the transfer of calibration models between Fourier transform near-infrared (FT-NIR) instruments from four different manufacturers. The piecewise direct standardization (PDS) method is compared with the new hybrid calibration method known as prediction augmented classical least squares/partial least squares (PACLS/PLS). The success of a calibration transfer experiment is judged by prediction error and by the number of samples that are flagged as outliers that would not have been flagged as such if a complete recalibration were performed. Prediction results must be acceptable and the outlier diagnostics capabilities must be preserved for the transfer to be deemed successful. Previous studies have measured the success of a calibration transfer method by comparing only the prediction performance (e.g., the root mean square error of prediction, RMSEP). However, our study emphasizes the need to consider outlier detection performance as well. As our study illustrates, the RMSEP values for a calibration transfer can be within acceptable range; however, statistical analysis of the spectral residuals can show that differences in outlier performance can vary significantly between competing transfer methods. There was no statistically significant difference in the prediction error between the PDS and PACLS/PLS methods when the same subset sample selection method was used for both methods. However, the PACLS/PLS method was better at preserving the outlier detection capabilities and therefore was judged to have performed better than the PDS algorithm when transferring calibrations with the use of a subset of samples to define the transfer function. The method of sample subset selection was found to make a significant difference in the calibration transfer results using the PDS algorithm, while the transfer results were less sensitive to subset selection when the PACLS/PLS method was used.


2017 ◽  
Vol 2017 ◽  
pp. 1-11 ◽  
Author(s):  
Zhengyan Xia ◽  
Chu Zhang ◽  
Haiyong Weng ◽  
Pengcheng Nie ◽  
Yong He

Hyperspectral imaging (HSI) technology has increasingly been applied as an analytical tool in fields of agricultural, food, and Traditional Chinese Medicine over the past few years. The HSI spectrum of a sample is typically achieved by a spectroradiometer at hundreds of wavelengths. In recent years, considerable effort has been made towards identifying wavelengths (variables) that contribute useful information. Wavelengths selection is a critical step in data analysis for Raman, NIRS, or HSI spectroscopy. In this study, the performances of 10 different wavelength selection methods for the discrimination of Ophiopogon japonicus of different origin were compared. The wavelength selection algorithms tested include successive projections algorithm (SPA), loading weights (LW), regression coefficients (RC), uninformative variable elimination (UVE), UVE-SPA, competitive adaptive reweighted sampling (CARS), interval partial least squares regression (iPLS), backward iPLS (BiPLS), forward iPLS (FiPLS), and genetic algorithms (GA-PLS). One linear technique (partial least squares-discriminant analysis) was established for the evaluation of identification. And a nonlinear calibration model, support vector machine (SVM), was also provided for comparison. The results indicate that wavelengths selection methods are tools to identify more concise and effective spectral data and play important roles in the multivariate analysis, which can be used for subsequent modeling analysis.


2016 ◽  
Vol 10 (4-5) ◽  
pp. 125-130
Author(s):  
Henry De-Graft Acquah

This paper introduces the rank-based estimation method to modelling the Cobb-Douglas production function as an alternative to the least squares approach. The intent is to demonstrate how a nonparametric regression based on a rank-based estimator can be used to estimate a Cobb-Douglas production function using data on maize production from Ghana. The nonparametric results are compared to common parametric specification using the ordinary least squares regression. Results of the study indicate that the estimated coefficients of the CobbDouglas Model using the Least squares method and the rank-based regression analysis are similar. Findings indicated that in both estimation techniques, land and Equipment had a significant and positive influence on output whilst agrochemicals had a significantly negative effect on output. Additionally, seeds which also had a negative influence on output was found to be significant in the robust rank-based estimation, but insignificant in the ordinary least square estimation. Both the least squares and rank-based regression suggest that the farmers were operating at an increasing returns to scale. In effect this paper demonstrate the usefulness of the rank-based estimation in production analysis. JEL CODE: Q18, D24, Q12, C1 and C67


2002 ◽  
Vol 10 (1) ◽  
pp. 45-51 ◽  
Author(s):  
Mulualem Tigabu ◽  
Per Christer Odén

Near infrared (NIR) spectroscopy was used to classify insect-infested and sound seeds of a tropical multipurpose tree, Cordia africana Lam. A calibration model derived by partial least squares regression of orthogonal signal corrected spectra resulted in a 100% classification rate. Difference spectrum and partial least squares weight indicated that absorbance differences between insect-infested and sound seeds might have been due to differences in composition of chitin and cuticular lipid components as well as moisture content. The result shows the possibility of using NIR spectroscopy in the seed cleaning process in the future provided that appropriate sorting instruments are developed.