scholarly journals Multi-Steps Fragmentation-Ion Trap Mass Spectrometry Coupled to Liquid Chromatography Diode Array System for Investigation of Olaparib Related Substances

Molecules ◽  
2019 ◽  
Vol 24 (5) ◽  
pp. 843 ◽  
Author(s):  
Alaa Khedr ◽  
Soad El-Hay ◽  
Ahmed Kammoun

A high-performance liquid chromatography-diode array-mass spectrometric (LC-DAD-MS) method was developed and validated to investigate the related substances of olaparib (OLA) in bulk form. OLA was exposed to acid–base hydrolysis, boiling, oxidation with hydrogen peroxide, and UV light followed by LC-DAD-MS analysis. OLA and OLA-related substances were simultaneously and quantitatively monitored by DAD at 278 nm and triple quadrupole mass spectrometry (QQQ-MS). The investigated compounds were auto-scanned by an ion trap MS which applied positive and negative modes separately. The fragmentation pathway was confirmed by applying multi-steps fragmentation to identify the resulted cleaved ions and their parent ion. OLA was found to be sensitive to the alkaline hydrolysis and less sensitive to UV light. Two major hydrolytic degradation products, including the protonated molar ions m/z 299 and m/z 367, were identified. Three potential impurities were also characterized. The LC-MS limit of detection (LOD) and limit of quantification (LOQ) were 0.01 and 0.05 ng/µL, respectively. The quantitative results obtained by LC-DAD was comparable with that of LC-QQQ-MS. The proposed method shows good intra-day and inter-day precision with relative standard deviation (RSD) <2%.

2006 ◽  
Vol 20 (20) ◽  
pp. 3101-3110 ◽  
Author(s):  
Stefanie Leonard ◽  
Monica Ferraro ◽  
Erwin Adams ◽  
Jos Hoogmartens ◽  
Ann Van Schepdael

2009 ◽  
Vol 92 (1) ◽  
pp. 302-306 ◽  
Author(s):  
Xiao-Jing Yan ◽  
Xiao-Mei Liang ◽  
Yan-Jun Xu ◽  
Shu-Hui Jin ◽  
Dao-Quan Wang

Abstract A method was developed for the determination of 7B3 (12-propyloxyimino-1,15-pentadecanlactam), a novel macrolactam fungicide, by liquid chromatography/mass spectrometry (LC/MS) with positive electrospray ionization (ESI+). The method used a reversed-phase C18 column and acetonitrilewater (60 + 40, v/v) mobile phase. The quick, easy, cheap, effective, rugged, and safe method was used for extraction of 7B3 from cotton plants, which involved the extraction of 10 g homogenized sample with 10 mL acetonitrile, followed by the addition of 4 g anhydrous MgSO4 and 1.0 g NaCl. After centrifugation, 1 mL of the buffered acetonitrile extract was transferred into a tube containing 50 mg primary secondary amine sorbent and 100 mg anhydrous MgSO4. After shaking and centrifugation, the final extract was transferred to an autosampler vial for concurrent analysis by LC/MS. The results of 7B3 determined by LC/MS in the selective ion monitoring mode were linear, and the matrix effect of the method was evaluated. The average recoveries of 7B3 fortified at different levels were within 84.1100.2, and the relative standard deviations were &lt;7.5 for all samples analyzed. The method limit of detection and the limit of quantitation values were 0.03 and 0.1 mg/kg, respectively. The proposed method was successfully applied to determine 7B3 residues in practical samples. This method is sensitive, accurate, reliable, simple, and safe.


Molecules ◽  
2020 ◽  
Vol 25 (19) ◽  
pp. 4399
Author(s):  
Dasom Shin ◽  
Hui-Seung Kang ◽  
Hyungsoo Kim ◽  
Guiim Moon

In this work, liquid chromatography–tandem mass spectrometry (LC-MS/MS) method was developed and validated for screening and confirmation of 64 illicit compounds in dietary supplements. The target compounds were illegally used pharmaceutical drugs, prohibited compounds, and not authorized ingredients for different therapeutics (sexual enhancement, weight loss, muscular strengthening, and relaxing products). The validation procedure was performed to evaluate selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, and precision according to the Association of Official Analytical Chemists guidelines. The linearity was >0.98 in the range of 0.5–200 µg L−1. The LOQs were in the range 1–10 µg kg−1 for all target compounds. The accuracy (expressed as recovery) was 78.5–114%. The precision (expressed as the relative standard deviation) was below 9.15%. The developed method was applied for the determination of illicit compounds in dietary supplements collected from websites. As a result, the total detection rate was 13.5% (27 samples detected in 200 samples). The concentrations of detected samples ranged from 0.51 to 226 mg g−1. The proposed methodology is suitable for monitoring the adulteration of illicit compounds in dietary supplements.


Sign in / Sign up

Export Citation Format

Share Document