scholarly journals Development of a Novel Method for Identification of Alaria alata Mesocercariae by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

2021 ◽  
Vol 9 (8) ◽  
pp. 1664
Author(s):  
Carolyn Kästner ◽  
Peter Bahn ◽  
Ralph Schönfelder ◽  
Zanda Ozoliņa ◽  
Laura Alksne ◽  
...  

Alaria (A.) alata mesocercariae (AM) have increasingly appeared as incidental findings during the mandatory inspection of wild boars for Trichinella in many European countries. An Alaria spp.-specific PCR is available for the identification of AM; however, it is time- and cost-intensive. Therefore, we propose a rapid and cost-efficient MALDI-TOF assay for the identification of AM in wild boar meat that can be applied in routine diagnostics. In this study, a fast and methodologically simple protocol for the protein extraction of AM from different host species in different countries was established, and an AM-specific reference spectra database was created as part of the ongoing development of an existing Trichinella spp. database. A formic acid protein extraction was performed after pooling 10 AM from the same host individual. In total, 61 main spectra profiles (MSPs) from different host individuals were stored in an AM-specific MSP library. The cluster analysis of these 61 MSPs indicated a possible variation within the A. alata species with a tentative association with the geographical origin of the host, but not the host species. This MALDI-TOF assay allows for a fast verification of the AM isolates, which is the next step in the development of a universal database for the identification of several parasites isolated from meat.

2021 ◽  
Author(s):  
Bing Ma ◽  
Yunqi Tian ◽  
Yungang Han ◽  
Lifang Ban ◽  
Junwen Yang ◽  
...  

ABSTRACTNocardia is an important cause of clinically invasive disease, but for most clinical laboratories, identification of these isolates to the species level is challenging. Recently, matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been widely used for identification of most bacterial and fungal isolates. In this multicenter study, we evaluated the identification of Nocardia isolates using Autof MS1000 and Bruker Biotyper. A total of 86 non-duplicate Nocardia isolates from 7 hospital laboratories were evaluated. Further, we carried out sequence analysis of 16S rRNA, gyrB, secA1, hsp65, and rpoB genes as a reference method for Nocardia species identification. The 86 isolates were directly spotted on the target plate and plate protein extraction was performed. Data were analyzed by SPSS 19.0. In total, 72 (83.7%) strains (score ≥ 9.0) and 70 (81.4%) strains (score ≥ 2.0) were correctly identified by the Autof MS1000 and Bruker Biotyper systems, respectively, at the species level. There was no significant difference (P > 0.05) between the two systems using the same protein extraction method. In conclusion, the Autof MS 1000 and Bruker MALDI-TOF systems showed no difference in identification of Nocardia spp. to the species level and could meet the most important clinical requirement for species identification.


2018 ◽  
Vol 56 (4) ◽  
Author(s):  
David Rodriguez-Temporal ◽  
Daniel Perez-Risco ◽  
Eduardo A. Struzka ◽  
Mireia Mas ◽  
Fernando Alcaide

ABSTRACTMatrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) has proved to be a useful diagnostic method for identifying conventional bacteria. In the case of mycobacteria, a good protein extraction protocol is essential in order to obtain reliable identification results. To date, no such protocol has been definitively established. The aim of this study was to compare the manufacturer's recommended protein extraction protocol (protocol A) with two novel protocols (protocols B and C), which apply different freezing temperatures and mechanical disruption times using an automatic tissue homogenizer. A total of 302 clinical isolates, comprising 41 nontuberculous mycobacteria (NTM) species, were grown in parallel on solid and liquid media and analyzed: 174 isolates were slow-growing mycobacteria (SGM) and 128 isolates were rapid-growing mycobacteria (RGM). Overall, MALDI-TOF MS identified a higher number of NTM isolates from solid than from liquid media, especially with protocol C (83.4 and 68.2%, respectively;P< 0.05). From solid media, this protein extraction method identified 57.9 and 3.9% more isolates than protocols A (P< 0.001) and B (P< 0.05), respectively. In the case of liquid media, protocol C identified 49.7 and 6.3% more isolates than protocols A and B, respectively (P< 0.001). With regard to the growth rate, MALDI-TOF MS identified more RGM isolates than SGM isolates in all of the protocols studied. In conclusion, the application of freezing and automatic tissue homogenizer improved protein extraction of NTM and boosted identification rates. Consequently, MALDI-TOF MS, which is a cheap and simple method, could be a helpful tool for identifying NTM species in clinical laboratories.


2013 ◽  
Vol 7 (1) ◽  
pp. 135-141 ◽  
Author(s):  
Melanie Pavlovic ◽  
Ingrid Huber ◽  
Regina Konrad ◽  
Ulrich Busch

Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has recently emerged as a powerful tool for the routine identification of clinical isolates. MALDI-TOF MS based identification of bacteria has been shown to be more rapid, accurate and cost-efficient than conventional phenotypic techniques or molecular methods. Rapid and reliable identification of food-associated bacteria is also of crucial importance for food processing and product quality. This review is concerned with the applicability of MALDI-TOF MS for routine identification of foodborne bacteria taking the specific requirements of food microbiological laboratories and the food industry into account. The current state of knowledge including recent findings and new approaches are discussed.


Author(s):  
Monika Akimowicz ◽  
Joanna Bucka-Kolendo

Microbiological purity control of food products is of great importance in the food industry. Contaminated food is often characterized by a deteriorated taste, smell, and appearance, and when consumed, it can pose a threat to human health and life. Also, contamination incurs huge financial losses to the food industry. Different methods are used for identification of the microorganisms isolated from food, which are based on phenotypic, immunologic, genetic, and spectroscopic techniques. Unfortunately, these methods have the following disadvantages: laborious, time-consuming, requiring a well-trained spectrometer operator with specialist knowledge, or very accurate, but complicated, and extremely expensive. In recent years, matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) has been gaining increasing importance in the field of food microbiology. Unlike other techniques used for microorganisms identification, MALDI-TOF MS is more rapid, accurate and cost-efficient, and easy to perform. Thus, this method can be applied in the food industry to quickly and accurately identify microorganisms, which is crucial for controlling the quality of food products. The present review aims to discuss the selected applications of MALDI-TOF MS in food microbiology. It mainly focuses on the characteristics of this method and its potential use in the identification and typing of microorganisms including filamentous fungi, yeasts, and bacteria in fermented beverages (beer and wine), honey, dairy products like yogurt and pasteurized milk, pork, and seafood.


2015 ◽  
Vol 2015 ◽  
pp. 1-8 ◽  
Author(s):  
John Hoon Rim ◽  
Yangsoon Lee ◽  
Sung Kuk Hong ◽  
Yongjung Park ◽  
MyungSook Kim ◽  
...  

While pulsed-field gel electrophoresis (PFGE) is recognized as the gold standard method for clonality analysis, MALDI-TOF MS has recently been spotlighted as an alternative tool for species identification. Herein, we compared the dendrograms of multi-drug-resistant (MDR)Acinetobacter baumanniiisolates by using MALDI-TOF MS with those by using PFGE. We used direct colony and protein extraction methods for MALDI-TOF MS dendrograms. The isolates with identical PFGE patterns were grouped into different branches in MALDI-TOF MS dendrograms. Among the isolates that were classified as very close isolates in MALDI-TOF MS dendrogram, PFGE band patterns visually showed complete differences. We numeralized similarity among isolates by measuring distance levels. The Spearman rank correlation coefficient values were 0.449 and 0.297 between MALDI-TOF MS dendrogram using direct colony and protein extraction method versus PFGE, respectively. This study is the first paper focusing solely on the dendrogram function of MALDI-TOF MS compared with PFGE. Although MALDI-TOF MS is a promising tool to identify species in a rapid manner, our results showed that MALDI-TOF MS dendrograms could not substitute PFGE for MDRAcinetobacter baumanniiclonality analysis.


Antibiotics ◽  
2021 ◽  
Vol 10 (3) ◽  
pp. 262
Author(s):  
Isabel Carvalho ◽  
Nadia Safia Chenouf ◽  
Rita Cunha ◽  
Carla Martins ◽  
Paulo Pimenta ◽  
...  

The aim of the study was to analyze the mechanisms of resistance in extended-spectrum beta-lactamase (ESBL)- and acquired AmpC (qAmpC)-producing Escherichia coli isolates from healthy and sick cats in Portugal. A total of 141 rectal swabs recovered from 98 sick and 43 healthy cats were processed for cefotaxime-resistant (CTXR) E. coli recovery (in MacConkey agar supplemented with 2 µg/mL cefotaxime). The matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) method was used for E. coli identification and antimicrobial susceptibility was performed by a disk diffusion test. The presence of resistance/virulence genes was tested by PCR sequencing. The phylogenetic typing and multilocus sequence typing (MLST) were determined by specific PCR sequencing. CTXRE. coli isolates were detected in seven sick and six healthy cats (7.1% and 13.9%, respectively). Based on the synergy tests, 11 of 13 CTXRE. coli isolates (one/sample) were ESBL-producers (ESBL total rate: 7.8%) carrying the following ESBL genes: blaCTX-M-1 (n = 3), blaCTX-M-15 (n = 3), blaCTX-M-55 (n = 2), blaCTX-M-27 (n = 2) and blaCTX-M-9 (n = 1). Six different sequence types were identified among ESBL-producers (sequence type/associated ESBLs): ST847/CTX-M-9, CTX-M-27, CTX-M-1; ST10/CTX-M-15, CTX-M-27; ST6448/CTX-M-15, CTX-M-55; ST429/CTX-M-15; ST101/CTX-M-1 and ST40/CTX-M-1. Three of the CTXR isolates were CMY-2-producers (qAmpC rate: 2.1%); two of them were ESBL-positive and one ESBL-negative. These isolates were typed as ST429 and ST6448 and were obtained in healthy or sick cats. The phylogenetic groups A/B1/D/clade 1 were detected among ESBL- and qAmpC-producing isolates. Cats are carriers of qAmpC (CMY-2)- and ESBL-producing E. coli isolates (mostly of variants of CTX-M group 1) of diverse clonal lineages, which might represent a public health problem due to the proximity of cats with humans regarding a One Health perspective.


2014 ◽  
Vol 63 (9) ◽  
pp. 1143-1147 ◽  
Author(s):  
Katherine Woods ◽  
David Beighton ◽  
John L. Klein

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) provides rapid, accurate and cost-effective identification of a range of bacteria and is rapidly changing the face of routine diagnostic microbiology. However, certain groups of bacteria, for example streptococci (in particular viridans or non-haemolytic streptococci), are less reliably identified by this method. We studied the performance of MALDI-TOF MS for identification of the ‘Streptococcus anginosus group’ (SAG) to species level. In total, 116 stored bacteraemia isolates identified by conventional methods as belonging to the SAG were analysed by MALDI-TOF MS. Partial 16S rRNA gene sequencing, supplemented with sialidase activity testing, was performed on all isolates to provide ‘gold standard’ identification against which to compare MALDI-TOF MS performance. Overall, 100 % of isolates were correctly identified to the genus level and 93.1 % to the species level by MALDI-TOF MS. However, only 77.6 % were correctly identified to the genus level and 59.5 % to the species level by a MALDI-TOF MS direct transfer method alone. Use of a rapid in situ extraction method significantly improved identification rates when compared with the direct transfer method (P<0.001). We recommend routine use of this method to reduce the number of time-consuming full extractions required for identification of this group of bacteria by MALDI-TOF MS in the routine diagnostic laboratory. Only 22 % (1/9) of Streptococcus intermedius isolates were reliably identified by MALDI-TOF MS to the species level, even after full extraction. MALDI-TOF MS reliably identifies S. anginosus and Streptococcus constellatus to the species level but does not reliably identify S. intermedius.


2021 ◽  
Vol 9 (3) ◽  
pp. 661
Author(s):  
Adriana Calderaro ◽  
Mirko Buttrini ◽  
Monica Martinelli ◽  
Benedetta Farina ◽  
Tiziano Moro ◽  
...  

Typing methods are needed for epidemiological tracking of new emerging and hypervirulent strains because of the growing incidence, severity and mortality of Clostridioides difficile infections (CDI). The aim of this study was the evaluation of a typing Matrix-Assisted Desorption/Ionization-Time of Flight Mass Spectrometry (MALDI-TOF MS (T-MALDI)) method for the rapid classification of the circulating C. difficile strains in comparison with polymerase chain reaction (PCR)-ribotyping results. Among 95 C. difficile strains, 10 ribotypes (PR1–PR10) were identified by PCR-ribotyping. In particular, 93.7% of the isolates (89/95) were grouped in five ribotypes (PR1–PR5). For T-MALDI, two classifying algorithm models (CAM) were tested: the first CAM involved all 10 ribotypes whereas the second one only the PR1–PR5 ribotypes. Better performance was obtained using the second CAM: recognition capability of 100%, cross-validation of 96.6% and agreement of 98.4% (60 correctly typed strains, limited to PR1–PR5 classification, out of 61 examined strains) with PCR-ribotyping results. T-MALDI seems to represent an alternative to PCR-ribotyping in terms of reproducibility, set up time and costs, as well as a useful tool in epidemiological investigation for the detection of C. difficile clusters (either among CAM included ribotypes or out-of-CAM ribotypes) involved in outbreaks.


2016 ◽  
Vol 10 (1) ◽  
pp. 202-208 ◽  
Author(s):  
Marisa Almuzara ◽  
Claudia Barberis ◽  
Viviana Rojas Velázquez ◽  
Maria Soledad Ramirez ◽  
Angela Famiglietti ◽  
...  

Objective:To evaluate the performance of matrix-assisted laser desorption ionization-time-of-flight mass spectrometry (MALDI-TOF MS) by using 190 Catalase-negative Gram-Positive Cocci (GPC) clinical isolates.Methods:All isolates were identified by conventional phenotypic tests following the proposed scheme by Ruoff and Christensen and MALDI-TOF MS (Bruker Daltonics, BD, Bremen, Germany). Two different extraction methods (direct transfer formic acid method on spot and ethanol formic acid extraction method) and different cut-offs for genus/specie level identification were used. The score cut-offs recommended by the manufacturer (≥ 2.000 for species-level, 1.700 to 1.999 for genus level and <1.700 no reliable identification) and lower cut-off scores (≥1.500 for genus level, ≥ 1.700 for species-level and score <1.500 no reliable identification) were considered for identification. A minimum difference of 10% between the top and next closest score was required for a different genus or species.MALDI-TOF MS identification was considered correct when the result obtained from MS database agreed with the phenotypic identification result.When both methods gave discordant results, the 16S rDNA orsodAgenes sequencing was considered as the gold standard identification method. The results obtained by MS concordant with genes sequencing, although discordant with conventional phenotyping, were considered correct. MS results discordant with 16S orsodA identification were considered incorrect.Results:Using the score cut-offs recommended by the manufacturer, 97.37% and 81.05% were correctly identified to genus and species level, respectively. On the other hand, using lower cut-off scores for identification, 97.89% and 94.21% isolates were correctly identified to genus and species level respectively by MALDI-TOF MS and no significant differences between the results obtained with two extraction methods were obtained.Conclusion:The results obtained suggest that MALDI-TOF MS has the potential of being an accurate tool for Catalase-negative GPC identification even for those species with difficult diagnosis asHelcococcus,Abiotrophia,Granulicatella, among others. Nevertheless, expansion of the library, especially including more strains with different spectra on the same species might overcome potential “intraspecies” variability problems. Moreover, a decrease of the identification scores for species and genus-level identification must be considered since it may improve the MALDI-TOF MS accuracy.


2017 ◽  
Vol 29 (5) ◽  
pp. 622-627 ◽  
Author(s):  
Rinosh J. Mani ◽  
Anil J. Thachil ◽  
Akhilesh Ramachandran

Accurate and timely identification of infectious etiologies is of great significance in veterinary microbiology, especially for critical diseases such as strangles, a highly contagious disease of horses caused by Streptococcus equi subsp. equi. We evaluated a matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) platform for use in species- and subspecies-level identification of S. equi isolates from horses and compared it with an automated biochemical system. We used 25 clinical isolates each of S. equi subsp. equi and S. equi subsp. zooepidemicus. Using the MALDI-TOF MS platform, it was possible to correctly identify all 50 isolates to the species level. Unique mass peaks were identified in the bacterial peptide mass spectra generated by MALDI-TOF MS, which can be used for accurate subspecies-level identification of S. equi. Mass peaks (mass/charge, m/ z) 6,751.9 ± 1.4 (mean ± standard deviation) and 5,958.1 ± 1.3 were found to be unique to S. equi subsp. equi and S. equi subsp. zooepidemicus, respectively. The automated biochemical system correctly identified 47 of 50 of the isolates to the species level as S. equi, whereas at the subspecies level, 24 of 25 S. equi subsp. equi isolates and 22 of 25 S. equi subsp. zooepidemicus isolates were correctly identified. Our results indicate that MALDI-TOF MS can be used for accurate species- and subspecies-level identification of S. equi.


Sign in / Sign up

Export Citation Format

Share Document