scholarly journals Negative Pressure Provides Simple and Stable Droplet Generation in a Flow-Focusing Microfluidic Device

Micromachines ◽  
2021 ◽  
Vol 12 (6) ◽  
pp. 662
Author(s):  
Nikita A. Filatov ◽  
Anatoly A. Evstrapov ◽  
Anton S. Bukatin

Droplet microfluidics is an extremely useful and powerful tool for industrial, environmental, and biotechnological applications, due to advantages such as the small volume of reagents required, ultrahigh-throughput, precise control, and independent manipulations of each droplet. For the generation of monodisperse water-in-oil droplets, usually T-junction and flow-focusing microfluidic devices connected to syringe pumps or pressure controllers are used. Here, we investigated droplet-generation regimes in a flow-focusing microfluidic device induced by the negative pressure in the outlet reservoir, generated by a low-cost mini diaphragm vacuum pump. During the study, we compared two ways of adjusting the negative pressure using a compact electro-pneumatic regulator and a manual airflow control valve. The results showed that both types of regulators are suitable for the stable generation of monodisperse droplets for at least 4 h, with variations in diameter less than 1 µm. Droplet diameters at high levels of negative pressure were mainly determined by the hydrodynamic resistances of the inlet microchannels, although the absolute pressure value defined the generation frequency; however, the electro-pneumatic regulator is preferable and convenient for the accurate control of the pressure by an external electric signal, providing more stable pressure, and a wide range of droplet diameters and generation frequencies. The method of droplet generation suggested here is a simple, stable, reliable, and portable way of high-throughput production of relatively large volumes of monodisperse emulsions for biomedical applications.

Micromachines ◽  
2020 ◽  
Vol 11 (8) ◽  
pp. 743
Author(s):  
Zhaoqin Yin ◽  
Zemin Huang ◽  
Xiaohui Lin ◽  
Xiaoyan Gao ◽  
Fubing Bao

The demand for highly controllable droplet generation methods is very urgent in the medical, materials, and food industries. The droplet generation in a flow-focusing microfluidic device with external mechanical vibration, as a controllable droplet generation method, is experimentally studied. The effects of vibration frequency and acceleration amplitude on the droplet generation are characterized. The linear correlation between the droplet generation frequency and the external vibration frequency and the critical vibration amplitude corresponding to the imposing vibration frequency are observed. The droplet generation frequency with external mechanical vibration is affected by the natural generation frequency, vibration frequency, and vibration amplitude. The droplet generation frequency in a certain microfluidic device with external vibration is able to vary from the natural generation frequency to the imposed vibration frequency at different vibration conditions. The evolution of dispersed phase thread with vibration is remarkably different with the process without vibration. Distinct stages of expansion, shrinkage, and collapse are observed in the droplet formation with vibration, and the occurrence number of expansion–shrinkage process is relevant with the linear correlation coefficient.


Micromachines ◽  
2020 ◽  
Vol 11 (4) ◽  
pp. 406
Author(s):  
Chun-Dong Xue ◽  
Xiao-Dong Chen ◽  
Yong-Jiang Li ◽  
Guo-Qing Hu ◽  
Tun Cao ◽  
...  

Droplet microfluidics involving non-Newtonian fluids is of great importance in both fundamental mechanisms and practical applications. In the present study, breakup dynamics in droplet generation of semi-dilute polymer solutions in a microfluidic flow-focusing device were experimentally investigated. We found that the filament thinning experiences a transition from a flow-driven to a capillary-driven regime, analogous to that of purely elastic fluids, while the highly elevated viscosity and complex network structures in the semi-dilute polymer solutions induce the breakup stages with a smaller power-law exponent and extensional relaxation time. It is elucidated that the elevated viscosity of the semi-dilute solution decelerates filament thinning in the flow-driven regime and the incomplete stretch of polymer molecules results in the smaller extensional relaxation time in the capillary-driven regime. These results extend the understanding of breakup dynamics in droplet generation of non-Newtonian fluids and provide guidance for microfluidic synthesis applications involving dense polymeric fluids.


Micromachines ◽  
2019 ◽  
Vol 10 (12) ◽  
pp. 812 ◽  
Author(s):  
Wen Zeng ◽  
Dong Xiang ◽  
Hai Fu

In a flow-focusing microdroplet generator, by changing the flow rates of the two immiscible fluids, production speed can be increased from tens to thousands of droplets per second. However, because of the nonlinearity of the flow-focusing microdroplet generator, the production speed of droplets is difficult to quantitatively study for the typical flow-focusing geometry. In this paper, we demonstrate an efficient method that can precisely predict the droplet production speed for a wide range of fluid flow rates. While monodisperse droplets are formed in the flow-focusing microchannel, droplet spacing as a function of time was measured experimentally. We discovered that droplet spacing changes periodically with time during each process of droplet generation. By comparing the frequency of droplet spacing fluctuations with the droplet production speed, precise predictions of droplet production speed can be obtained for different flow conditions in the flow-focusing microdroplet generator.


2021 ◽  
Author(s):  
Wen Zeng ◽  
Hai Fu

Abstract For droplet microfluidics, the electrical-detection method which can precisely detect the size of monodisperse droplets is demonstrated in this paper. In a Flow-focusing microdroplet generator, three pairs of the microelectrodes are allocated along the microchannel, and during the passing-by process of each droplet, both the length, the velocity and the production speed of the droplets can be obtained from the experimental measurements of the time-varying capacitance between each pair of the microelectrodes. Particularly, for different geometries of the Flow-focusing microchannel, the method of the electrical-detection is validated experimentally over a wide range of the typical conditions of monodisperse droplet production. In addition, the droplet size measured by the electrical-detection method is compared with that by the method of image processing, and the detection precision of the electrical-detection method is verified experimentally. Most importantly, by calculating the root-mean-square value of the droplet lengths for three pairs of the microelectrodes, the detection precision of the droplet size can be increased drastically.


Micromachines ◽  
2021 ◽  
Vol 12 (10) ◽  
pp. 1211
Author(s):  
Khashayar Bajgiran ◽  
Alejandro Cordova ◽  
Riad Elkhanoufi ◽  
James Dorman ◽  
Adam Melvin

Droplet microfluidics offers a wide range of applications, including high-throughput drug screening and single-cell DNA amplification. However, these platforms are often limited to single-input conditions that prevent them from analyzing multiple input parameters (e.g., combined cellular treatments) in a single experiment. Droplet multiplexing will result in higher overall throughput, lowering cost of fabrication, and cutting down the hands-on time in number of applications such as single-cell analysis. Additionally, while lab-on-a-chip fabrication costs have decreased in recent years, the syringe pumps required for generating droplets of uniform shape and size remain cost-prohibitive for researchers interested in utilizing droplet microfluidics. This work investigates the potential of simultaneously generating droplets from a series of three in-line T-junctions utilizing gravity-driven flow to produce consistent, well-defined droplets. Implementing reservoirs with equal heights produced inconsistent flow rates that increased as a function of the distance between the aqueous inlets and the oil inlet. Optimizing the three reservoir heights identified that taller reservoirs were needed for aqueous inlets closer to the oil inlet. Studying the relationship between the ratio of oil-to-water flow rates () found that increasing resulted in smaller droplets and an enhanced droplet generation rate. An ANOVA was performed on droplet diameter to confirm no significant difference in droplet size from the three different aqueous inlets. The work described here offers an alternative approach to multiplexed droplet microfluidic devices allowing for the high-throughput interrogation of three sample conditions in a single device. It also has provided an alternative method to induce droplet formation that does not require multiple syringe pumps.


2021 ◽  
Author(s):  
Florian V. De Rop ◽  
Joy N. Ismail ◽  
Carmen Bravo Gonzalez-Blas ◽  
Gert J. Hulselmans ◽  
Christopher C. Flerin ◽  
...  

Single-cell RNA-seq and single-cell ATAC-seq technologies are being used extensively to create cell type atlases for a wide range of organisms, tissues, and disease processes. To increase the scale of these atlases, lower the cost, and allow for more specialized multi-ome assays, custom droplet microfluidics may provide complementary solutions to commercial setups. We developed HyDrop, a flexible and generic droplet microfluidic platform encompassing three protocols. The first protocol involves creating dissolvable hydrogel beads with custom oligos that can be released in the droplets. In the second protocol, we demonstrate the use of these beads for HyDrop-ATAC, a low-cost non-commercial scATAC-seq protocol in droplets. After validating HyDrop-ATAC, we applied it to flash-frozen mouse cortex and generated 8,502 high-quality single-cell chromatin accessibility profiles in a single run. In the third protocol, we adapt both the reaction chemistry and the capture sequence of the barcoded hydrogel bead to capture mRNA, and demonstrate a significant improvement in throughput and sensitivity compared to previous open-source droplet-based scRNA-seq assays (Drop-seq and inDrop). Similarly, we applied HyDrop-RNA to flash-frozen mouse cortex and generated 9,508 single-cell transcriptomes closely matching reference single-cell gene expression data. Finally, we leveraged HyDrop-RNA's high capture rate to analyse a small population of FAC-sorted neurons from the Drosophila brain, confirming the protocol's applicability to low-input samples and small cells. HyDrop is currently capable of generating single-cell data in high throughput and at a reduced cost compared to commercial methods, and we envision that HyDrop can be further developed to be compatible with novel (multi-) omics protocols.


2017 ◽  
Vol 89 (8) ◽  
pp. 4387-4391 ◽  
Author(s):  
Adrian J. T. Teo ◽  
King-Ho Holden Li ◽  
Nam-Trung Nguyen ◽  
Wei Guo ◽  
Nadine Heere ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document