scholarly journals Rapid Fabrication of Microfluidic Devices for Biological Mimicking: A Survey of Materials and Biocompatibility

Micromachines ◽  
2021 ◽  
Vol 12 (3) ◽  
pp. 346
Author(s):  
Hui Ling Ma ◽  
Ana Carolina Urbaczek ◽  
Fayene Zeferino Ribeiro de Souza ◽  
Paulo Augusto Gomes Garrido Carneiro Leão ◽  
Janice Rodrigues Perussi ◽  
...  

Microfluidics is an essential technique used in the development of in vitro models for mimicking complex biological systems. The microchip with microfluidic flows offers the precise control of the microenvironment where the cells can grow and structure inside channels to resemble in vivo conditions allowing a proper cellular response investigation. Hence, this study aimed to develop low-cost, simple microchips to simulate the shear stress effect on the human umbilical vein endothelial cells (HUVEC). Differentially from other biological microfluidic devices described in the literature, we used readily available tools like heat-lamination, toner printer, laser cutter and biocompatible double-sided adhesive tapes to bind different layers of materials together, forming a designed composite with a microchannel. In addition, we screened alternative substrates, including polyester-toner, polyester-vinyl, glass, Permanox® and polystyrene to compose the microchips for optimizing cell adhesion, then enabling these microdevices when coupled to a syringe pump, the cells can withstand the fluid shear stress range from 1 to 4 dyne cm2. The cell viability was monitored by acridine orange/ethidium bromide (AO/EB) staining to detect live and dead cells. As a result, our fabrication processes were cost-effective and straightforward. The materials investigated in the assembling of the microchips exhibited good cell viability and biocompatibility, providing a dynamic microenvironment for cell proliferation. Therefore, we suggest that these microchips could be available everywhere, allowing in vitro assays for daily laboratory experiments and further developing the organ-on-a-chip concept.

2020 ◽  
Author(s):  
Thomas Brendan Smith ◽  
Alessandro Marco De Nunzio ◽  
Kamlesh Patel ◽  
Haydn Munford ◽  
Tabeer Alam ◽  
...  

Fluid shear stress is a key modulator of cellular physiology in vitro and in vivo, but its effects are under-investigated due to requirements for complicated induction methods. Herein we report the validation of ShearFAST; a smartphone application that measures the rocking profile on a standard laboratory cell rocker and calculates the resulting shear stress arising in tissue culture plates. The accuracy with which this novel approach measured rocking profiles was validated against a graphical analysis, and also against measures reported by an 8-camera motion tracking system. ShearFASTs angle assessments correlated well with both analyses (r ≥0.99, p ≤0.001) with no significant differences in pitch detected across the range of rocking angles tested. Rocking frequency assessment by ShearFAST also correlated well when compared to the two independent validatory techniques (r ≥0.99, p ≤0.0001), with excellent reproducibility between ShearFAST and video analysis (mean frequency measurement difference of 0.006 ± 0.005Hz) and motion capture analysis (mean frequency measurement difference of 0.008 ± 0.012Hz). These data make the ShearFAST assisted cell rocker model make it an attractive approach for economical, high throughput fluid shear stress experiments. Proof of concept data presented reveals a protective effect of low-level shear stress on renal proximal tubule cells submitted to simulations of pretransplant storage.


Nanoscale ◽  
2018 ◽  
Vol 10 (32) ◽  
pp. 15249-15261 ◽  
Author(s):  
M. Juliana Gomez-Garcia ◽  
Amber L. Doiron ◽  
Robyn R. M. Steele ◽  
Hagar I. Labouta ◽  
Bahareh Vafadar ◽  
...  

Hemodynamic factors drive nanoparticle distribution in vivo and in vitro in cell-based flow models.


2009 ◽  
Vol 131 (8) ◽  
Author(s):  
Liam T. Breen ◽  
Peter E. McHugh ◽  
Bruce P. Murphy

Over the past 25 years, many laboratory based bioreactors have been used to study the cellular response to hemodynamic forces. The vast majority of these studies have focused on the effect of a single isolated hemodynamic force, generally consisting of a wall shear stress (WSS) or a tensile hoop strain (THS). However, investigating the cellular response to a single isolated force does not accurately represent the true in vivo situation, where a number of forces are acting simultaneously. This study used a novel bioreactor to investigate the cellular response of human umbilical vein endothelial cells (HUVECs) exposed to a combination of steady WSS and a range of cyclic THS. HUVECs exposed to a range of cyclic THS (0–12%), over a 12 h testing period, expressed an upregulation of both ICAM-1 and VCAM-1. HUVECs exposed to a steady WSS (0 dynes/cm2 and 25 dynes/cm2), over a 12 h testing period, also exhibited an ICAM-1 upregulation but a VCAM-1 downregulation, where the greatest level of WSS stimulus resulted in the largest upregulation and downregulation of ICAM-1 and VCAM-1, respectively. A number of HUVEC samples were exposed to a high steady WSS (25 dynes/cm2) combined with a range of cyclic THS (0–4%, 0–8%, and 0–12%) for a 12 h testing period. The initial ICAM-1 upregulation, due to the WSS alone, was downregulated with the addition of a cyclic THS. It was observed that the largest THS (0–12%) had the greatest reducing effect on the ICAM-1 upregulation. Similarly, the initial VCAM-1 downregulation, due to the high steady WSS alone, was further downregulated with the addition of a cyclic THS. A similar outcome was observed when HUVEC samples were exposed to a low steady WSS combined with a range of cyclic THS. However, the addition of a THS to the low WSS did not result in an expected ICAM-1 downregulation. In fact, it resulted in a trend of unexpected ICAM-1 upregulation. The unexpected cellular response to the combination of a steady WSS and a cyclic THS demonstrates that such a response could not be determined by simply superimposing the cellular responses exhibited by ECs exposed to a steady WSS and a cyclic THS that were applied in isolation.


2020 ◽  
Author(s):  
Brandon J. DeOre ◽  
Paul P. Partyka ◽  
Fan Fan ◽  
Peter A. Galie

AbstractFluid shear stress is an important mediator of vascular permeability, yet the molecular mechanisms underlying the response of the blood-brain barrier to shear have yet to be studied in cerebral vasculature despite its importance for brain homeostasis. The goal of this study is to probe components of shear mechanotransduction within the blood-brain barrier to gain a better understanding of pathologies associated with changes in cerebral blood flow including ischemic stroke. Interrogating the effects of shear stress in vivo is complicated by the complexity of factors in the brain parenchyma and the difficulty associated with modulating blood flow regimes. Recent advances in the ability to mimic the in vivo microenvironment using three-dimensional in vitro models provide a controlled setting to study the response of the blood-brain barrier to shear stress. The in vitro model used in this study is compatible with real-time measurement of barrier function using transendothelial electrical resistance as well as immunocytochemistry and dextran permeability assays. These experiments reveal that there is a threshold level of shear stress required for barrier formation and that the composition of the extracellular matrix, specifically the presence of hyaluronan, dictates the flow response. Gene editing to modulate the expression of CD44, a receptor for hyaluronan that previous studies have identified to be mechanosensitive, demonstrates that the receptor is required for the endothelial response to shear stress. Manipulation of small GTPase activity reveals CD44 activates Rac1 while inhibiting RhoA activation. Additionally, adducin-γ localizes to tight junctions in response to shear stress and RhoA inhibition and is required to maintain the barrier. This study identifies specific components of the mechanosensing complex associated with the blood-brain barrier response to fluid shear stress, and therefore illuminates potential targets for barrier manipulation in vivo.


2021 ◽  
Author(s):  
Shashi Kant ◽  
Khanh-Van Tran ◽  
Miroslava Kvandova ◽  
Amada D. Caliz ◽  
Hyung-Jin Yoo ◽  
...  

Fluid shear stress (FSS) is known to mediate multiple phenotypic changes in the endothelium. Laminar FSS (undisturbed flow) is known to promote endothelial alignment to flow that is key to stabilizing the endothelium and rendering it resistant to atherosclerosis and thrombosis. The molecular pathways responsible for endothelial responses to FSS are only partially understood. Here we have identified peroxisome proliferator gamma coactivator-1α (PGC-1α) as a flow-responsive gene required for endothelial flow alignment in vitro and in vivo. Compared to oscillatory FSS (disturbed flow) or static conditions, laminar FSS (undisturbed flow) increased PGC-1α expression and its transcriptional co-activation. PGC-1α was required for laminar FSS-induced expression of telomerase reverse transcriptase (TERT) in vitro and in vivo via its association with ERRα and KLF4 on the TERT promoter. We found that TERT inhibition attenuated endothelial flow alignment, elongation, and nuclear polarization in response to laminar FSS in vitro and in vivo. Among the flow-responsive genes sensitive to TERT status was heme oxygenase-1 (HMOX1), a gene required for endothelial alignment to laminar FSS. Thus, these data suggest an important role for a PGC-1α-TERT-HMOX1 axis in the endothelial stabilization response to laminar FSS.


1999 ◽  
Vol 19 (2) ◽  
pp. 281-289 ◽  
Author(s):  
Parul Houston ◽  
Marion C. Dickson ◽  
Valerie Ludbrook ◽  
Brian White ◽  
Jean-Luc Schwachtgen ◽  
...  

2000 ◽  
Vol 20 (3) ◽  
pp. 617-623 ◽  
Author(s):  
Boris-Wolfgang Hochleitner ◽  
Elisabeth-Olga Hochleitner ◽  
Peter Obrist ◽  
Thomas Eberl ◽  
Albert Amberger ◽  
...  

Author(s):  
Shashi Kant ◽  
Khanh-Van Tran ◽  
Miroslava Kvandova ◽  
Amada D. Caliz ◽  
Hyung-Jin Yoo ◽  
...  

Objective: Fluid shear stress (FSS) is known to mediate multiple phenotypic changes in the endothelium. Laminar FSS (undisturbed flow) is known to promote endothelial alignment to flow, which is key to stabilizing the endothelium and rendering it resistant to atherosclerosis and thrombosis. The molecular pathways responsible for endothelial responses to FSS are only partially understood. In this study, we determine the role of PGC1α (peroxisome proliferator gamma coactivator-1α)-TERT (telomerase reverse transcriptase)-HMOX1 (heme oxygenase-1) during shear stress in vitro and in vivo. Approach and Results: Here, we have identified PGC1α as a flow-responsive gene required for endothelial flow alignment in vitro and in vivo. Compared with oscillatory FSS (disturbed flow) or static conditions, laminar FSS (undisturbed flow) showed increased PGC1α expression and its transcriptional coactivation. PGC1α was required for laminar FSS-induced expression of TERT in vitro and in vivo via its association with ERRα(estrogen-related receptor alpha) and KLF (Kruppel-like factor)-4 on the TERT promoter. We found that TERT inhibition attenuated endothelial flow alignment, elongation, and nuclear polarization in response to laminar FSS in vitro and in vivo. Among the flow-responsive genes sensitive to TERT status, HMOX1 was required for endothelial alignment to laminar FSS. Conclusions: These data suggest an important role for a PGC1α-TERT-HMOX1 axis in the endothelial stabilization response to laminar FSS.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Timothy G. Hammond ◽  
Corey Nislow ◽  
Ivan C. Christov ◽  
Vecihi Batuman ◽  
Pranay P. Nagrani ◽  
...  

AbstractRotating forms of suspension culture allow cells to aggregate into spheroids, prevent the de-differentiating influence of 2D culture, and, perhaps most importantly of all, provide physiologically relevant, in vivo levels of shear stress. Rotating suspension culture technology has not been widely implemented, in large part because the vessels are prohibitively expensive, labor-intensive to use, and are difficult to scale for industrial applications. Our solution addresses each of these challenges in a new vessel called a cell spinpod. These small 3.5 mL capacity vessels are constructed from injection-molded thermoplastic polymer components. They contain self-sealing axial silicone rubber ports, and fluoropolymer, breathable membranes. Here we report the two-fluid modeling of the flow and stresses in cell spinpods. Cell spinpods were used to demonstrate the effect of fluid shear stress on renal cell gene expression and cellular functions, particularly membrane and xenobiotic transporters, mitochondrial function, and myeloma light chain, cisplatin and doxorubicin, toxicity. During exposure to myeloma immunoglobulin light chains, rotation increased release of clinically validated nephrotoxicity cytokine markers in a toxin-specific pattern. Addition of cisplatin or doxorubicin nephrotoxins reversed the enhanced glucose and albumin uptake induced by fluid shear stress in rotating cell spinpod cultures. Cell spinpods are a simple, inexpensive, easily automated culture device that enhances cellular functions for in vitro studies of nephrotoxicity.


2012 ◽  
Vol 5 (3) ◽  
pp. 266-276 ◽  
Author(s):  
Gunes Uzer ◽  
Sarah L. Manske ◽  
M. Ete Chan ◽  
Fu-Pen Chiang ◽  
Clinton T. Rubin ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document