scholarly journals A Sample-In-Answer-Out Microfluidic System for the Molecular Diagnostics of 24 HPV Genotypes Using Palm-Sized Cartridge

Micromachines ◽  
2021 ◽  
Vol 12 (3) ◽  
pp. 263
Author(s):  
Rui Wang ◽  
Jing Wu ◽  
Xiaodong He ◽  
Peng Zhou ◽  
Zuojun Shen

This paper proposes an automated microfluidic system for molecular diagnostics that integrates the functions of a traditional polymerase chain reaction (PCR) laboratory into a palm-sized microfluidic cartridge (CARD) made of polystyrene. The CARD integrates 4 independent microfluidic sample lanes, which can independently complete a sample test, and each sample lane integrates the 3 functional areas of the sample preparation area, PCR amplification area, and product analysis area. By using chemical cell lysis, magnetic silica bead-based DNA extraction, combined with multi-PCR-reverse dot hybridization with microarray, 24 HPV genotypes can be typing tested in CARD. With a custom-made automated CARD operating platform, the entire process can be automatically carried out, achieving sample-in-answer-out. The custom-made operation platform is developed based on a liquid handling station-type, which can automatically load off-chip reagents without placing reagents in CARD in advance. The platform can control six CARDs to work simultaneously, detect 24 samples at a time. The results show that the limit of detection of the microfluidic system is 200 copies/test, and the positive detection rate of clinical samples by this system is 100%, which is an effective method for detection of HPV.

2021 ◽  
Author(s):  
Mingjie Dai ◽  
Wenzhe Ma ◽  
Hong Kang ◽  
Matthew Sonnett ◽  
George M. Church ◽  
...  

The management of pandemics such as COVID-19 requires highly scalable and sensitive viral diagnostics, together with variant identification. Next-generation sequencing (NGS) has many attractive features for highly multiplexed testing, however current sequencing-based methods are limited in throughput by early processing steps on individual samples (e.g. RNA extraction and PCR amplification). Here we report a new method, "One-Seq", that eliminates the current bottlenecks in scalability by enabling early pooling of samples, before any extraction or amplification steps. To enable early pooling, we developed a one-pot reaction for efficient reverse transcription (RT) and upfront barcoding in extraction-free clinical samples, and a "protector" strategy in which carefully designed competing oligonucleotides prevent barcode crosstalk and preserve detection of the high dynamic range of viral load in clinical samples. This method is highly sensitive, achieving a limit of detection (LoD) down to 2.5 genome copy equivalent (gce) in contrived RT samples, 10 gce in multiplexed sequencing, and 2-5 gce with multi-primer detection, suggesting an LoD of 200-500 gce/ml for clinical testing. In clinical specimens, One-Seq showed quantitative viral detection against clinical Ct values with 6 logs of linear dynamic range and detection of SARS-CoV-2 positive samples down to ~360 gce/ml. In addition, One-Seq reports a number of hotspot viral mutations at equal scalability at no extra cost. Scaling up One-Seq would allow a throughput of 100,000-1,000,000 tests per day per single clinical lab, at an estimated amortized reagent cost of $1.5 per test and turn-around time of 7.5-15 hr.


Micromachines ◽  
2020 ◽  
Vol 11 (2) ◽  
pp. 203 ◽  
Author(s):  
Yonghee Kim ◽  
Abdurhaman Teyib Abafogi ◽  
Buu Minh Tran ◽  
Jaewon Kim ◽  
Jinyeop Lee ◽  
...  

Influenza A viruses are often present in environmental and clinical samples at concentrations below the limit of detection (LOD) of molecular diagnostics. Here we report an integrated microfluidic preconcentration and nucleic amplification system (μFPNAS) which enables both preconcentration of influenza A virus H1N1 (H1N1) and amplification of its viral RNA, thereby lowering LOD for H1N1. H1N1 virus particles were first magnetically preconcentrated using magnetic nanoparticles conjugated with an antibody specific for the virus. Their isolated RNA was amplified to cDNA through thermocycling in a trapezoidal chamber of the μFPNAS. A detection limit as low as 100 TCID50 (50% tissue culture infective dose) in saliva can be obtained within 2 hours. These results suggest that the LOD of molecular diagnostics for virus can be lowered by systematically combining immunomagnetic separation and reverse transcriptase-polymerase chain reaction (RT-PCR) in one microfluidic device.


Genes ◽  
2020 ◽  
Vol 11 (10) ◽  
pp. 1183 ◽  
Author(s):  
Gustavo Barcelos Barra ◽  
Ticiane Henriques Santa Rita ◽  
Pedro Góes Mesquita ◽  
Rafael Henriques Jácomo ◽  
Lídia Freire Abdalla Nery

WHO declared the novel coronavirus (COVID-19) outbreak a global pandemic on 11 March 2020. The establishment of standardized RT-qPCR protocols for respiratory secretions testing, as well as sharing of specimens, data, and information became critical. Here, we investigate the analytical performance of two interim RT-qPCR protocols (Charité and Centers for Disease Control (CDC)) for the qualitative detection of SARS-CoV-2 executed in a fully automated platform. Analytical specificity, PCR amplification efficiency, analytical sensitivity (limit of detection), and cross-reactivity were evaluated using contrived samples. The on-going accuracy was evaluated by retrospective analysis of our test results database (real clinical samples). N1, E, and a modified version of RdRP assays presented adequate analytical specificity, amplification efficiency, and analytical sensitivity using contrived samples. The three assays were applied to all individuals who requested the SARS-CoV-2 molecular test assay in our laboratory and it was observed that N1 gave more positive results than E, and E gave more positive results than RdRP (modified). The RdRP and E were removed from the test and its final version, based on N1 assay only, was applied to 30,699 Brazilian individuals (from 19 February 2020 to 8 May 2020). The aggregated test results available in the database were also presented.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Alexia Bordigoni ◽  
Anne Motte ◽  
Hervé Tissot-Dupont ◽  
Philippe Colson ◽  
Christelle Desnues

AbstractHuman papillomaviruses (HPV) play a key role in promoting human anogenital cancers. Current high-risk HPV screening or diagnosis tests involve cytological or molecular techniques mostly based on qualitative HPV DNA detection. Here, we describe the development of a rapid quantitative polymerase chain reaction (qPCR) detection test of HPV16 and HPV18 oncogenes (E6 and E7) normalized on human gene encoding GAPDH. Optimized qPCR parameters were defined, and analytical specificities were validated. The limit of detection was 101 for all genes tested. Assay performances were evaluated on clinical samples (n = 96). Concordance between the Xpert HPV assay and the triplex assay developed here was 93.44% for HPV16 and 73.58% for HPV18. HPV co-infections were detected in 15 samples. The systems developed in the present study can be used in complement to traditional HPV tests for specifically validating the presence of HPV16 and/or HPV18. It can also be used for the follow-up of patients with confirmed infection and at risk of developing lesions, through the quantification of E6 and E7 oncogene expression (mRNA) normalized on the GAPDH expression levels.


2020 ◽  
Vol 7 (Supplement_1) ◽  
pp. S278-S279
Author(s):  
Dorottya Nagy-Szakal ◽  
Mara Couto-Rodriguez ◽  
Joseph Barrows ◽  
Heather L Wells ◽  
Marilyne Debieu ◽  
...  

Abstract Background COVID-19 had spread quickly, causing an international public health emergency with an alarming global shortage of COVID-19 diagnostic tests. We developed and clinically validated a next-generation sequencing (NGS)-based target enrichment assay with the COVID-DX Software tailored for the detection, characterization, and surveillance of the SARS-CoV-2 viral genome. Methods The SARS-CoV-2 NGS assay consists of components including library preparation, target enrichment, sequencing, and a COVID-DX Software analysis tool. The NGS library preparation starts with extracted RNA from nasopharyngeal (NP) swabs followed by cDNA synthesis and conversion to Illumina TruSeq-compatible libraries using the Twist Library Preparation Kit via Enzymatic Fragmentation and Unique Dual Indices (UDI). The library is then enriched for SARS-CoV-2 sequences using a panel of dsDNA biotin-labeled probes, specifically designed to target the SARS-CoV-2 genome, then sequenced on an Illumina NextSeq 550 platform. The COVID-DX Software analyzes sequence results and provides a clinically oriented report, including the presence/absence of SARS-CoV-2 for diagnostic use. An additional research use only report describes the assay performance, estimated viral titer, coverage across the viral genome, genetic variants, and phylogenetic analysis. Results The SARS-CoV-2 NGS Assay was validated on 30 positive and 30 negative clinical samples. To measure the sensitivity and specificity of the assay, the positive and negative percent agreement (PPA, NPA) was defined in comparison to an orthogonal EUA RT-PCR assay (PPA [95% CI]: 96.77% [90.56%-100%] and NPA [95% CI]: 100% [100%-100%]). Data reported using our assay defined the limit of detection to be 40 copies/ml using heat-inactivated SARS-CoV-2 viral genome in clinical matrices. In-silico analysis provided >99.9% coverage across the SARS-CoV-2 viral genome and no cross-reactivity with evolutionarily similar respiratory pathogens. Conclusion The SARS-CoV-2 NGS Assay powered by the COVID-DX Software can be used to detect the SARS-CoV-2 virus and provide additional insight into viral titer and genetic variants to track transmission, stratify risk, predict outcome and therapeutic response, and control the spread of infectious disease. Disclosures Dorottya Nagy-Szakal, MD PhD, Biotia (Employee) Mara Couto-Rodriguez, MS, Biotia (Employee) Joseph Barrows, MS, Biotia, Inc. (Employee, Shareholder) Heather L. Wells, MPH, Biotia (Consultant) Marilyne Debieu, PhD, Biotia (Employee) Courteny Hager, BS, Biotia (Employee) Kristin Butcher, MS, Twist Bioscience (Employee) Siyuan Chen, PhD, Twist Bioscience (Employee) Christopher Mason, PhD, Biotia (Board Member, Employee, Shareholder) Niamh B. O’Hara, PhD, Biotia (Board Member, Employee, Shareholder)Twist (Other Financial or Material Support, I am CEO of Biotia and Biotia has business partnership with Twist)


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Anita G. Amin ◽  
Prithwiraj De ◽  
Barbara Graham ◽  
Roger I. Calderon ◽  
Molly F. Franke ◽  
...  

AbstractOur study sought to determine whether urine lipoarabinomannan (LAM) could be validated in a sample cohort that consisted mainly of HIV uninfected individuals that presented with tuberculosis symptoms. We evaluated two tests developed in our laboratory, and used them on clinical samples from Lima, Peru where incidence of HIV is low. ELISA analysis was performed on 160 samples (from 140 adult culture-confirmed TB cases and 20 symptomatic TB-negative child controls) using 100 μL of urine after pretreatment with Proteinase K. Two different mouse monoclonal antibodies-CS35 and CHCS9-08 were used individually for capture of urine LAM. Among cases, optical density (OD450) values had a positive association with higher bacillary loads. The 20 controls had negative values (below the limit of detection). The assay correctly identified all samples (97–100% accuracy confidence interval). For an alternate validation of the ELISA results, we analyzed all 160 urine samples using an antibody independent chemoanalytical approach. Samples were called positive only when LAM surrogates—tuberculostearic acid (TBSA) and d-arabinose (d-ara)—were found to be present in similar amounts. All TB cases, including the 40 with a negative sputum smear had LAM in detectable quantities in urine. None of the controls had detectable amounts of LAM. Our study shows that urinary LAM detection is feasible in HIV uninfected, smear negative TB patients.


Cancers ◽  
2021 ◽  
Vol 13 (1) ◽  
pp. 139
Author(s):  
Caterina De Luca ◽  
Francesco Pepe ◽  
Antonino Iaccarino ◽  
Pasquale Pisapia ◽  
Luisella Righi ◽  
...  

Gene fusions represent novel predictive biomarkers for advanced non-small cell lung cancer (NSCLC). In this study, we validated a narrow NGS gene panel able to cover therapeutically-relevant gene fusions and splicing events in advanced-stage NSCLC patients. To this aim, we first assessed minimal complementary DNA (cDNA) input and the limit of detection (LoD) in different cell lines. Then, to evaluate the feasibility of applying our panel to routine clinical samples, we retrospectively selected archived lung adenocarcinoma histological and cytological (cell blocks) samples. Overall, our SiRe RNA fusion panel was able to detect all fusions and a splicing event harbored in a RNA pool diluted up to 2 ng/µL. It also successfully analyzed 46 (95.8%) out of 48 samples. Among these, 43 (93.5%) out of 46 samples reproduced the same results as those obtained with conventional techniques. Intriguingly, the three discordant results were confirmed by a CE-IVD automated real-time polymerase chain reaction (RT-PCR) analysis (Easy PGX platform, Diatech Pharmacogenetics, Jesi, Italy). Based on these findings, we conclude that our new SiRe RNA fusion panel is a valid and robust tool for the detection of clinically relevant gene fusions and splicing events in advanced NSCLC.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Shan Wei ◽  
Esther Kohl ◽  
Alexandre Djandji ◽  
Stephanie Morgan ◽  
Susan Whittier ◽  
...  

AbstractThe COVID-19 pandemic has resulted in an urgent need for a rapid, point of care diagnostic testing that could be rapidly scaled on a worldwide level. We developed and tested a highly sensitive and robust assay based on reverse transcription loop mediated isothermal amplification (RT-LAMP) that uses readily available reagents and a simple heat block using contrived spike-in and actual clinical samples. RT-LAMP testing on RNA-spiked samples showed a limit of detection (LoD) of 2.5 copies/μl of viral transport media. RT-LAMP testing directly on clinical nasopharyngeal swab samples in viral transport media had an 85% positive percentage agreement (PPA) (17/20), and 100% negative percentage agreement (NPV) and delivered results in 30 min. Our optimized RT-LAMP based testing method is a scalable system that is sufficiently sensitive and robust to test for SARS-CoV-2 directly on clinical nasopharyngeal swab samples in viral transport media in 30 min at the point of care without the need for specialized or proprietary equipment or reagents. This cost-effective and efficient one-step testing method can be readily available for COVID-19 testing world-wide, especially in resource poor settings.


2021 ◽  
Vol 7 (6) ◽  
pp. 433
Author(s):  
Ahmad Ibrahim ◽  
Lucie Peyclit ◽  
Rim Abdallah ◽  
Saber Khelaifia ◽  
Amanda Chamieh ◽  
...  

Candida auris is an emerging multidrug-resistant yeast causing nosocomial infections and associated with high mortality in immunocompromised patients. Rapid identification and characterisation are necessary for diagnosis and containing its spread. In this study, we present a selective culture medium for all C. auris clades. This medium is sensitive with a limit of detection ranging between 101 and 102 CFU/mL. The 100% specificity of SCA (specific C. auris) medium is confirmed on a set of 135 Candida strains, 50 bacterial species and 200 human stool samples. Thus, this medium specifically selects for C. auris isolation from clinical samples, allowing the latter to study its phenotypic profile.


Sensors ◽  
2020 ◽  
Vol 20 (7) ◽  
pp. 1820
Author(s):  
Jeningsih ◽  
Ling Ling Tan ◽  
Alizar Ulianas ◽  
Lee Yook Heng ◽  
Nur-Fadhilah Mazlan ◽  
...  

A DNA micro-optode for dengue virus detection was developed based on the sandwich hybridization strategy of DNAs on succinimide-functionalized poly(n-butyl acrylate) (poly(nBA-NAS)) microspheres. Gold nanoparticles (AuNPs) with an average diameter of ~20 nm were synthesized using a centrifugation-based method and adsorbed on the submicrometer-sized polyelectrolyte-coated poly(styrene-co-acrylic acid) (PSA) latex particles via an electrostatic method. The AuNP–latex spheres were attached to the thiolated reporter probe (rDNA) by Au–thiol binding to functionalize as an optical gold–latex–rDNA label. The one-step sandwich hybridization recognition involved a pair of a DNA probe, i.e., capture probe (pDNA), and AuNP–PSA reporter label that flanked the target DNA (complementary DNA (cDNA)). The concentration of dengue virus cDNA was optically transduced by immobilized AuNP–PSA–rDNA conjugates as the DNA micro-optode exhibited a violet hue upon the DNA sandwich hybridization reaction, which could be monitored by a fiber-optic reflectance spectrophotometer at 637 nm. The optical genosensor showed a linear reflectance response over a wide cDNA concentration range from 1.0 × 10−21 M to 1.0 × 10−12 M cDNA (R2 = 0.9807) with a limit of detection (LOD) of 1 × 10−29 M. The DNA biosensor was reusable for three consecutive applications after regeneration with mild sodium hydroxide. The sandwich-type optical biosensor was well validated with a molecular reverse transcription polymerase chain reaction (RT-PCR) technique for screening of dengue virus in clinical samples, e.g., serum, urine, and saliva from dengue virus-infected patients under informed consent.


Sign in / Sign up

Export Citation Format

Share Document