scholarly journals Synthesis of Magnetite Nanoparticles through a Lab-on-Chip Device

Materials ◽  
2021 ◽  
Vol 14 (19) ◽  
pp. 5906
Author(s):  
Cristina Chircov ◽  
Alexandra Cătălina Bîrcă ◽  
Alexandru Mihai Grumezescu ◽  
Bogdan Stefan Vasile ◽  
Ovidiu Oprea ◽  
...  

Magnetite nanoparticles (MNPs) represent one of the most intensively studied types of iron oxide nanoparticles in various fields, including biomedicine, pharmaceutics, bioengineering, and industry. Since their properties in terms of size, shape, and surface charge significantly affects their efficiency towards the envisaged application, it is fundamentally important to develop a new synthesis route that allows for the control and modulation of the nanoparticle features. In this context, the aim of the present study was to develop a new method for the synthesis of MNPs. Specifically, a microfluidic lab-on-chip (LoC) device was used to obtain MNPs with controlled properties. The study investigated the influence of iron precursor solution concentration and flowed onto the final properties of the nanomaterials. The synthesized MNPs were characterized in terms of size, morphology, structure, composition, and stability. Results proved the formation of magnetite as a single mineral phase. Moreover, the uniform spherical shape and narrow size distribution were demonstrated. Optimal characteristics regarding MNPs crystallinity, uniformity, and thermal stability were obtained at higher concentrations and lower flows. In this manner, the potential of the LoC device is a promising tool for the synthesis of nanomaterials by ensuring the necessary uniformity for all final applications.

2021 ◽  
pp. 2004101
Author(s):  
Marco Giacometti ◽  
Francesca Milesi ◽  
Pietro Lorenzo Coppadoro ◽  
Alberto Rizzo ◽  
Federico Fagiani ◽  
...  
Keyword(s):  

Polymers ◽  
2021 ◽  
Vol 13 (7) ◽  
pp. 1113
Author(s):  
Mohammed Asadullah Khan ◽  
Jürgen Kosel

An integrated polymer-based magnetohydrodynamic (MHD) pump that can actuate saline fluids in closed-channel devices is presented. MHD pumps are attractive for lab-on-chip applications, due to their ability to provide high propulsive force without any moving parts. Unlike other MHD devices, a high level of integration is demonstrated by incorporating both laser-induced graphene (LIG) electrodes as well as a NdFeB magnetic-flux source in the NdFeB-polydimethylsiloxane permanent magnetic composite substrate. The effects of transferring the LIG film from polyimide to the magnetic composite substrate were studied. Operation of the integrated magneto hydrodynamic pump without disruptive bubbles was achieved. In the studied case, the pump produces a flow rate of 28.1 µL/min. while consuming ~1 mW power.


Nanophotonics ◽  
2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Ali Rostamian ◽  
Ehsan Madadi-Kandjani ◽  
Hamed Dalir ◽  
Volker J. Sorger ◽  
Ray T. Chen

Abstract Thanks to the unique molecular fingerprints in the mid-infrared spectral region, absorption spectroscopy in this regime has attracted widespread attention in recent years. Contrary to commercially available infrared spectrometers, which are limited by being bulky and cost-intensive, laboratory-on-chip infrared spectrometers can offer sensor advancements including raw sensing performance in addition to use such as enhanced portability. Several platforms have been proposed in the past for on-chip ethanol detection. However, selective sensing with high sensitivity at room temperature has remained a challenge. Here, we experimentally demonstrate an on-chip ethyl alcohol sensor based on a holey photonic crystal waveguide on silicon on insulator-based photonics sensing platform offering an enhanced photoabsorption thus improving sensitivity. This is achieved by designing and engineering an optical slow-light mode with a high group-index of n g  = 73 and a strong localization of modal power in analyte, enabled by the photonic crystal waveguide structure. This approach includes a codesign paradigm that uniquely features an increased effective path length traversed by the guided wave through the to-be-sensed gas analyte. This PIC-based lab-on-chip sensor is exemplary, spectrally designed to operate at the center wavelength of 3.4 μm to match the peak absorbance for ethanol. However, the slow-light enhancement concept is universal offering to cover a wide design-window and spectral ranges towards sensing a plurality of gas species. Using the holey photonic crystal waveguide, we demonstrate the capability of achieving parts per billion levels of gas detection precision. High sensitivity combined with tailorable spectral range along with a compact form-factor enables a new class of portable photonic sensor platforms when combined with integrated with quantum cascade laser and detectors.


2021 ◽  
Vol 23 (2) ◽  
Author(s):  
Subhan Shaik ◽  
Aarthi Saminathan ◽  
Deepak Sharma ◽  
Jagdish A Krishnaswamy ◽  
D Roy Mahapatra

Biosensors ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 65
Author(s):  
Puneet Manocha ◽  
Gitanjali Chandwani

Molecular communication is a bioinspired communication that enables macro-scale, micro-scale and nano-scale devices to communicate with each other. The molecular communication system is prone to severe signal attenuation, dispersion and delay, which leads to performance degradation as the distance between two communicating devices increases. To mitigate these challenges, relays are used to establish reliable communication in microfluidic channels. Relay assisted molecular communication systems can also enable interconnection among various entities of the lab-on-chip for sharing information. Various relaying schemes have been proposed for reliable molecular communication systems, most of which lack practical feasibility. Thus, it is essential to design and develop relays that can be practically incorporated into the microfluidic channel. This paper presents a novel design of passive in-line relay for molecular communication system that can be easily embedded in the microfluidic channel and operate without external energy. Results show that geometric modification in the microfluidic channel can act as a relay and restore the degraded signal up-to 28%.


2021 ◽  
Vol 8 (14) ◽  
pp. 2170087
Author(s):  
Marco Giacometti ◽  
Francesca Milesi ◽  
Pietro Lorenzo Coppadoro ◽  
Alberto Rizzo ◽  
Federico Fagiani ◽  
...  
Keyword(s):  

2016 ◽  
Vol 20 (10) ◽  
Author(s):  
Nitipon Puttaraksa ◽  
Harry J. Whitlow ◽  
Mari Napari ◽  
Leena Meriläinen ◽  
Leona Gilbert
Keyword(s):  

2003 ◽  
Vol 18 (2) ◽  
pp. 357-362 ◽  
Author(s):  
Mary M. Sandstrom ◽  
Paul Fuierer

Control over crystallographic orientation in thin films is important, particularly with highly anisotropic structures. Because of its ferroelectric nature, the layered perovskite La2Ti2O7 has interesting piezoelectric and electrooptic properties that may be exploited when films are highly textured. Sol-gel films with an orientation factor of greater than 95% were fabricated without relying on epitaxial (lattice-matching) growth from the substrate. Film orientation and crystallization were confirmed by x-ray diffraction, scanning electron microscopy, atomic force microscopy, and optical measurements. The particle sizes in all precursor solutions were measured by dynamic light scattering experiments. Experimental results indicate that film orientation is a function of precursor solution concentration, size of the molecular clusters in the solution, and film thickness.


Proceedings ◽  
2018 ◽  
Vol 2 (13) ◽  
pp. 1018
Author(s):  
Giuseppe Fiorentino ◽  
Ben Jones ◽  
Sophie Roth ◽  
Edith Grac ◽  
Murali Jayapala ◽  
...  

A composite, capillary-driven microfluidic system suitable for transmitted light microscopy of cells (e.g., red and white human blood cells) is fabricated and demonstrated. The microfluidic system consists of a microchannels network fabricated in a photo-patternable adhesive polymer on a quartz substrate, which, by means of adhesive bonding, is then connected to a silicon microfluidic die (for processing of the biological sample) and quartz die (to form the imaging chamber). The entire bonding process makes use of a very low temperature budget (200 °C). In this demonstrator, the silicon die consists of microfluidic channels with transition structures to allow conveyance of fluid utilizing capillary forces from the polymer channels to the silicon channels and back to the polymer channels. Compared to existing devices, this fully integrated platform combines on the same substrate silicon microfluidic capabilities with optical system analysis, representing a portable and versatile lab-on-chip device.


Sign in / Sign up

Export Citation Format

Share Document