scholarly journals Angle of Insertion and Torsional Resistance of Nickel–Titanium Rotary Instruments

Materials ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3744
Author(s):  
Dario Di Nardo ◽  
Alessio Zanza ◽  
Marco Seracchiani ◽  
Orlando Donfrancesco ◽  
Gianluca Gambarini ◽  
...  

Previously published studies have investigated the influence of instrument access on cyclic fatigue resistance. However, no studies have evaluated the relationship between angulated access and torsional resistance. The aim of this study was to investigate the influence of the angle of access on the torsional resistance of endodontic instruments. One hundred and eighty instruments were selected: 90 F-One Blue 25/04 and 90 HeroShaper 25/04 instruments. Three subgroups (n = 30) for each instrument type (A and B) were established according to the angle of insertion of the instruments inside the artificial canal (0°, 10° and 20°). The tests were performed using a custom-made device consisting of the following: a motor that can record torque values of 0.1 s; interchangeable stainless-steel canals with different curvature (0°, 10° and 20°) that allow the instrument’s angulated insertion and keep it flexed during testing procedures; and a vise used to secure the instrument at 3 mm from the tip. Torque limit was set to 5.5 Ncm, and each instrument was rotated at 500 rpm until fracture occurred. Torque to fracture (TtF) was registered by the endodontic motor, and the fragment length (FL) was measured with a digital caliper. Fractographic analysis was performed using a scanning electron microscopy (SEM) evaluation to confirm the cause of failure. TtF values and fragment length (FL) values were statistically analyzed using one-way analysis of variance (ANOVA) test and the Bonferroni correction for multiple comparisons across the groups with significance set to a 95% confidence level. Regarding the F-One Blue instruments, the results showed a higher TtF for group A3 (20°) than for group A1 (0°) and group A2 (10°), with a statistically significant difference between group A3 and the other two groups (p < 0.05), whereas no statistically significant difference was found between group A1 and group A2 (p > 0.05). Regarding the HeroShaper instrument, the results showed the highest TtF for group B3, with a statistically significant difference between the three subgroups B1, B2 and B3 (p < 0.05). The results showed that the torsional resistance increases as the angle of instrument access increases with a varying intensity, according to the crystallographic phase of the instrument selected.

Materials ◽  
2021 ◽  
Vol 14 (21) ◽  
pp. 6324
Author(s):  
Alessio Zanza ◽  
Marco Seracchiani ◽  
Rodolfo Reda ◽  
Dario Di Nardo ◽  
Gianluca Gambarini ◽  
...  

The aim of this study was to assess the role of the crystallographic phase of Nickel-titanium (NiTi) rotary instruments in determining their torsional resistance during different bending conditions, such as different degrees and angles of curvature. 200 F-One 20.04 instruments (Fanta Dental, Shanghai, China) were used, 100 austenitic instruments and 100 martensitic instruments. Each group was divided in 5 subgroups according to the different bending conditions (straight canal, 90° or 60° of curvature degrees and 3 mm or 5 mm of radius of curvature). The static torsional test was performed by using a device composed of an electric motor capable of recording torque values (N·cm); a vice used to secure the instruments at 3 mm from the tip; and artificial canals, which allow instruments to remain flexed during test. Each instrument was rotated at 500 rpm with a torque limit set to 5.5 Ncm until its fracture. Torque at Fracture (TtF) was registered. A scanning electron microscopy (SEM) observation was conducted. The collected data confirm that an increase in the angle of curvature and a decrease in the radius of curvature of the artificial canals lead to an increase of TtF values with a statistically significant difference (p < 0.05), both in the austenitic and martensitic groups. Regarding the comparison between austenitic and martensitic groups in the same bending condition, a statistically significant difference was found only when the torsional test was performed in the canals with the degrees of curvature of 90° and the radius of curvature of 3 mm and 5 mm, with the austenitic instruments showing a higher TtF than the martensitic ones. In conclusion, it can be stated that the crystallographic phase influences the maximum torque at fracture when the instruments are subjected to severe bending and that the radius of curvature significantly influences their torsional resistance.


2016 ◽  
Vol 10 (02) ◽  
pp. 183-187 ◽  
Author(s):  
Thilla Sekar Vinothkumar ◽  
Deivanayagam Kandaswamy ◽  
Gopalakrishnan Prabhakaran ◽  
Arunachalam Rajadurai

ABSTRACT Objectives: The aim of this study was to investigate the role of deep cryogenic treatment (DCT) on the cyclic fatigue resistance and cutting efficiency of martensitic shape memory (SM) nickel–titanium (NiTi) rotary endodontic instruments. Materials and Methods: Seventy-five HyFlex® CM instruments were randomly divided into three groups of 25 each and subjected to different DCT (–185°C) conditions based on soaking time: DCT 24 group: 24 h, DCT 6 group: 6 h, and control group. Each group was randomly subdivided for evaluation of cyclic fatigue resistance in custom-made artificial canals (n = 15) and cutting efficiency in plexiglass simulators (n = 10). The cyclic fatigue resistance was measured by calculating the number of cycles to failure (NCF) and cutting efficiency was measured using the loss of weight method. Results: Increase in NCF of instruments in DCT 24 group was highly significant (P < 0.01; Tukey's honest significant difference). There was no difference in weight loss of plexiglass simulators in all the groups (P > 0.05; one-way analysis of variance). In conclusion, deep dry cryogenic treatment with 24 h soaking time significantly increases the cyclic fatigue resistance without affecting the cutting efficiency of SM NiTi endodontic instruments.


Materials ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2256
Author(s):  
Giusy Rita Maria La Rosa ◽  
Valeria Shumakova ◽  
Gaetano Isola ◽  
Francesco Indelicato ◽  
Calogero Bugea ◽  
...  

Background: To compare the influence of different temperatures and curvature radii on the cyclic fatigue resistance of F6 SkyTaper (F6ST) and One Curve (OC) single file nickel-titanium rotary instruments. Methods: A total of 120 instruments of F6ST and OC #25.06 were evaluated in 5 mm and 3 mm curvature radii at two temperatures (20 °C ± 1 °C and 37 °C ± 1 °C) in 16 mm stainless steel artificial canals associated with a curvature of 60°. The cyclic fatigue of tested files was assessed by employing a customized testing apparatus and expressed as times to fracture (TtF). A statistical analysis was performed with the significance level set at 95%. Results: All instruments decreased their TtF at 37 °C except for OC in the 3 mm radius, in which no significant difference was detected between 20 °C and 37 °C. A 3 mm curvature radius negatively affected TtF of all tested instruments, except for F6ST at 20 °C. F6ST had higher TtF than OC in the 3 mm radius at 20 °C, with no significant difference between them in the other tested conditions. Conclusions: Under the limits of the present in vitro study, body temperature impaired cyclic fatigue resistance of all files, except for OC in the 3 mm curvature radius. All instruments exhibited lower times to fracture in the 3 mm radius, excluding F6ST at 20 °C.


2021 ◽  
Vol 24 (4) ◽  
Author(s):  
Marco Seracchiani ◽  
Orlando Donfrancesco ◽  
Michela Relucenti ◽  
Rodolfo Reda ◽  
Alessio Zanza ◽  
...  

Objective: Aim of the present study is to evaluate mechanical properties of a newly developed rotary file, AF Rotary (Fanta Dental, Shanghai, China), and to compare these features with a worldwide spread rotary file, Protaper Gold F2 (PTG F2; Dentsply Maillefer, Ballaigues, Switzerland). Material and Methods: 60 AF Rotary 25.06 and 60 PTG F2 were divided in three groups of 20 files each. A group underwent to cyclic fatigue resistance tests, second group underwent to torsional resistance tests, third group underwent to bending tests. The statistical analysis was performed using t student test with significance level set at 95% (p < 0.05). Results: AF Rotary showed significantly higher torsional resistance and cyclic fatigue resistance (p < 0.05) when compared to the PTG F2. AF Rotary also showed significantly lower bending resistance (p < 0.05) when compared to the PTG F2. Conclusion: Therefore, within the limitations of this study, the results show better performances for AF Rotary compared to PTG F2 regarding the cyclic fatigue test, the torsional test and the bending test. Since the PTG F2 is a commonly used and widely investigated instrument it could be possible to state that the AF Rotary exhibits remarkable in vitro performances.   Keywords AF Rotary; Protaper gold; NiTi rotary instruments; Cyclic fatigue; Torsional resistance.


2021 ◽  
Vol 19 ◽  
pp. 228080002098740
Author(s):  
Haiyun Liu ◽  
Yanfeng Li ◽  
Guangquan Chai ◽  
Yuan Lv ◽  
Changjian Li ◽  
...  

Objective: To evaluate the effect of synchronous water irrigation on the fatigue resistance of nickel-titanium instrument. Methods: A standardized cyclic fatigue test models were established, and five types of nickel-titanium instruments (PTU F1, WO, WOG, RE, and M3) were applied. Each instrument was randomly divided into two groups ( N = 12). There was synchronous water irrigation in the experimental group, and no water irrigation in the control group. Besides, ProTaper Universal F1 was randomly divided into 10 groups ( N = 20). In the static group, nickel-titanium instruments were divided into one control group (no irrigation, N = 20) and six experimental group (irrigation, N = 20) based on different flow rate, angle and position; while in the dynamic group, instruments were divided into one control group (no irrigation, N = 20) and two experimental group (irrigation, N = 20) based on different flow rate. The rotation time (Time to Failure, TtF) of instruments was recorded and analyzed. Results: According to the static experiments, the TtF of instruments in all experimental groups was significantly higher than that in the static control group. Besides, the dynamic tests of PTU F1 showed that the TtF in the experimental group was significantly higher than that in the dynamic control group. Compared with control group, the TtF in the experimental groups increased by at least about 30% and up to 160%. The static and dynamic tests of PTU F1 showed that the TtF of nickel-titanium instrument in all experimental groups was significantly higher than that in the control group. However, there was no significant difference between any two experimental groups. Conclusion: Regardless of dynamic or static model, TtF with irrigation was longer than that with non-irrigation, indicating that synchronous irrigation can increase the fatigue resistance of nickel-titanium instrument. However, different irrigation conditions may have the same effect on the fatigue resistance.


Author(s):  
Wieslaw Blach ◽  
Miodrag Drapsin ◽  
Nemanja Lakicevic ◽  
Antonino Bianco ◽  
Tamara Gavrilovic ◽  
...  

Elite judo athletes undergo vigorous training to achieve outstanding results. In pursuit of achieving competitive success, the occurrence of injuries amongst judo athletes is not rare. The study aimed to perform a knee flexors and extensors isokinetic torque analysis in elite female judo athletes. Fifty-eight elite female judo athletes of the Serbian national team (21.02 ± 3.11 years; 62.36 ± 11.91 kg, 165.04 ± 10.24 cm, training experience 12.72 ± 2.98 years) volunteered to participate in this study. The range of motion (ROM) was set at 90⁰. Testing was performed in a concentric–concentric mode for the testing speed of 60 ⁰/s. Five maximal voluntary contractions of knee extensors and knee flexors muscle groups were measured for both legs. The obtained data showed a statistically significant difference in absolute torque values among different categories as heavier athletes demonstrated higher values. Post hoc analysis showed a significant difference between weight categories, as heavier athletes demonstrated higher values, while no significant differences in normalized torque values for different weight categories were observed. The implementation of new elements and training modalities may improve performance and prevent lateral asymmetry, thus reducing the risk of injury.


2018 ◽  
Vol 12 (4) ◽  
pp. 283-287 ◽  
Author(s):  
Gülşah Uslu ◽  
Taha Özyürek ◽  
Mustafa Gündoğar ◽  
Koray Yılmaz

Background. The aim of this study was to compare the cyclic fatigue resistance of 2Shape, Twisted File (TF) and EndoSequence Xpress (ESX) nickel-titanium rotary files at intracanal temperature (35°C). Methods. Twenty 2Shape TS1 (25/.04), 20 TF (25/.04) and 20 ESX (25/.04) files were tested for cyclic fatigue at intracanal temperature (35°C). All the instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, 60° angle of curvature and a radius curvature of 5 mm until fracture occurred; the time to fracture was recorded in seconds using a digital chronometer and the number of cycles to fracture (NCF) for each file was calculated. Kruskal-Wallis test with Bonferroni correction was performed to statistically analyze data using SPSS 21.0. Statistical significance was set at P<0.05. Results. NCF values revealed that the 2Shape had significantly the highest cyclic fatigue resistance, followed by TF and ESX at intracanal temperature (P<0.05). The difference was significant between the TF and ESX groups (P<0.05). There was no significant difference among the 2Shape, TF and ESX files with respect to the lengths of the fractured file fragments (P>.05). Conclusion. Within the limitations of present study, it was concluded that the cyclic fatigue resistance of 2Shape files at the intracanal temperature is higher than that of TF and ESX files.


2012 ◽  
Vol 38 (4) ◽  
pp. 527-530 ◽  
Author(s):  
Ju-Yeong Kim ◽  
Gary Shun-Pan Cheung ◽  
Se-Hee Park ◽  
Dae-Cheol Ko ◽  
Jin-Wook Kim ◽  
...  

2002 ◽  
Vol 58 (2) ◽  
Author(s):  
X.M. Mabasa ◽  
A. Stewart ◽  
C. Fleishman

The strength of the shoulder internal and external rotators incricket bowlers, may not be sufficient to cope with the demands of bowling.As very little research has been done on cricketers, this study was done to establish the isokinetic strength profile of the shoulder internal andexternal rotators in cricket bowlers.Isokinetic, shoulder rotational strength was evaluated in thirty malecricket volunteers with a mean age of 23.9 years and mean body weight of 70.3 kgs. The Cybex 340 dynamometer multi joint system was used to collect data on shoulder rotation strength in a standing neutral position. Data were collected at four different speeds (60,90,180 and 300deg/sec) and were computed for peak torque values for internal and external ratios for both dominant and non dominant shoulders.The results showed no statistically significant difference in the mean shoulder rotational torque between the bowlingand non-bowling shoulders for external rotation (p>0.05), and indicated statistically significant differences in themean shoulder rotational torque between the bowling and non-bowling shoulders for internal rotation (p<0.05). Therewas a significant decrease in isokinetic peak torque production for the external/internal rotator muscles as the speedof contraction increased (p<0.05). The peak torque ratio for the external/internal rotator muscles of the bowling armwere significantly less than of the non-bowling arm (p<0.05). These findings suggest that the strength ratios of thebowling arm need to be considered when managing young cricketers and their injuries.


Sign in / Sign up

Export Citation Format

Share Document