scholarly journals Effects of Plastic Waste on the Heat-Induced Spalling Performance and Mechanical Properties of High Strength Concrete

Materials ◽  
2020 ◽  
Vol 13 (15) ◽  
pp. 3262
Author(s):  
Abrahão Bernardo Rohden ◽  
Jessica Regina Camilo ◽  
Rafaela Cristina Amaral ◽  
Estela Oliari Garcez ◽  
Mônica Regina Garcez

This paper investigates a potential application of hard-to-recycle plastic waste as polymeric addition in high strength concrete, with a focus on the potential to mitigate heat-induced concrete spalling and the consequent effects on the mechanical properties. The waste corresponds to soft and hard plastic, including household polymers vastly disposed of in landfills, although technically recyclable. Mechanical and physical properties, cracking, mass loss, and the occurrence of spalling were assessed in high strength concrete samples produced with either plastic waste or polypropylene fibers after 2-h exposure to 600 °C. The analysis was supported by Scanning Electron Microscopy and X-Ray Computed Tomography images. The plastic waste is composed of different polymers with a thermal degradation between 250 to 500 °C. Polypropylene (PP) fibers and plastic waste dispersed in concrete have proved to play an essential role in mitigating heat-induced concrete spalling, contributing to the release of internal pressure after the polymer melting. The different morphology of plastic waste and polypropylene fibers leads to distinct mechanisms of action. While the vapor pressure dissipation network originated by polypropylene fibers is related to the formation of continuous channels, the plastic waste seems to cause discontinuous reservoirs and fewer damages into the concrete matrix. The incorporation of plastic waste improved heat-induced concrete spalling performance. While 6 kg/m3 of plastic increased the mechanical performance after exposure to high temperature, the incorporation of 3 kg/m3 resulted in mechanical properties comparable to the reference concrete.

2008 ◽  
Vol 73 (624) ◽  
pp. 341-347 ◽  
Author(s):  
Masashi MATSUDO ◽  
Hirokazu NISHIDA ◽  
Takahiro OHTSUKA ◽  
Takeo HIRASHIMA ◽  
Takeo ABE

2013 ◽  
Vol 357-360 ◽  
pp. 1328-1331
Author(s):  
Bai Rui Zhou ◽  
Dong Dong Han ◽  
Jian Hua Yang ◽  
Yi Liang Peng ◽  
Guo Xin Li

Portland cement, crushed stone, sand and superplasticizer were used to obtain a high strength concrete with a low water to binder ratio. A reticular polypropylene fiber and a single polypropylene fiber were used to improve the strength of the high strength concrete, but the effects of the two fibers on the slump and strengths were quite different. The reasons of the differences were the surface area and the modulus of elasticity of the fibers. The results show the reticular fiber was better to used in high strength concretes.


2010 ◽  
Vol 168-170 ◽  
pp. 945-948
Author(s):  
Shu Hua Liu

The properties of inorganic cohesive glue and its appliance to repairing ordinary and high strength concrete were studied in this paper. Inorganic cohesive glue not only has high strength, but also has equivalent coefficient of expansion with that of concrete and steel. The mechanical performance of inorganic cohesive glue is better than that of concrete, and other performances are similar to those of concrete. In the concrete repair work, it can mend the ruinate concrete well, and the strength of the repaired concrete is as high as or higher than that of original specimen.


2014 ◽  
Vol 1014 ◽  
pp. 49-52
Author(s):  
Xiao Ping Su

With the wide application of high strength concrete in the building construction,the risk making concrete subject to high temperatures during a fire is increasing. Comparison tests on the mechanical properties of high strength concrete (HSC) and normal strength concrete (NSC) after the action of high temperature were made in this article, which were compared from the following aspects: the peak stress, the peak strain, elasticity modulus, and stress-strain curve after high temperature. Results show that the laws of the mechanical properties of HSC and NSC changing with the temperature are the same. With the increase of heating temperature, the peak stress and elasticity modulus decreases, while the peak strain grows rapidly. HSC shows greater brittleness and worse fire-resistant performance than NSC, and destroys suddenly. The research and evaluation on the fire-resistant performance of HSC should be strengthened during the structural design and construction on the HSC buildings.


Author(s):  
Muhammad Armaghan Siffat ◽  
Muhammad Ishfaq ◽  
Afaq Ahmad ◽  
Khalil Ur Rehman ◽  
Fawad Ahmad

This study is supervised to assess the characteristics of the locally available wheat straw ash (WSA) to consume as a substitute to the cement and support in enhancing the mechanical properties of concrete. Initially, after incineration at optimum temperature of 800°C for 0.5, the ash of wheat straw was made up to the desirable level of fineness by passing through it to the several grinding cycles. Subsequently, the X-ray fluorescence (XRF) along with X-ray diffraction (XRD) testing conducted on ash of wheat straw for the evaluation its pozzolanic potential. Finally, the specimens of concrete were made by consuming 10% and 20% percentages of wheat straw ash as a replacement in concrete to conclude its impact on the compressive strength of high strength concrete. The cylinders of steel of dimensions 10cm diameter x 20cm depth were acquired to evaluate the compressive strength of high strength concrete. The relative outcomes of cylinders made of wheat straw ash substitution presented the slight increase in strength values of the concrete. Ultimately, the C-100 blends and WSA aided cement blends were inspected for the rheology of WSA through FTIR spectroscopy along with Thermogravimetric technique. The conclusions authenticate the WSA potential to replace cement in the manufacturing of the high strength concrete.


Sign in / Sign up

Export Citation Format

Share Document